메뉴 건너뛰기




Volumn 82, Issue 9, 2006, Pages 1238-1240

Treatment of enterocutaneous fistula in pancreas transplant recipients using percutaneous drainage and fibrin sealant: Three case reports

Author keywords

Fibrin sealant; Fistula; Pancreas transplantation; Tisseel

Indexed keywords

ANTIBIOTIC AGENT; FIBRIN GLUE;

EID: 33751012991     PISSN: 00411337     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.tp.0000228240.78290.28     Document Type: Article
Times cited : (16)

References (22)
  • 1
    • 0033960992 scopus 로고    scopus 로고
    • Decreased surgical risks of pancreas transplantation in the modern era
    • Humar A, Kandaswamy R, Granger D, et al. Decreased surgical risks of pancreas transplantation in the modern era. Ann Surg 2000; 231(2): 269.
    • (2000) Ann Surg , vol.231 , Issue.2 , pp. 269
    • Humar, A.1    Kandaswamy, R.2    Granger, D.3
  • 2
    • 0031885343 scopus 로고    scopus 로고
    • Surgical complications requiring early relaparotomy after pancreas transplantation: A multivariate risk factor and economic impact analysis of the cyclosporine era
    • Troppmann C, Gruessner AC, Dunn DL, et al. Surgical complications requiring early relaparotomy after pancreas transplantation: a multivariate risk factor and economic impact analysis of the cyclosporine era. Ann Surg 1998; 227(2): 255.
    • (1998) Ann Surg , vol.227 , Issue.2 , pp. 255
    • Troppmann, C.1    Gruessner, A.C.2    Dunn, D.L.3
  • 3
    • 0032821390 scopus 로고    scopus 로고
    • Surgical complications after pancreas transplantation with portal-enteric drainage
    • Reddy KS, Stratta RJ, Shokouh-Amiri MH, et al. Surgical complications after pancreas transplantation with portal-enteric drainage. J Am Coll Surg 1999; 189(3): 305.
    • (1999) J Am Coll Surg , vol.189 , Issue.3 , pp. 305
    • Reddy, K.S.1    Stratta, R.J.2    Shokouh-Amiri, M.H.3
  • 4
    • 0030037428 scopus 로고    scopus 로고
    • Fibrin sealant in thoracic surgery. Pulmonary applications, including management of bronchoplueral fistula
    • Bayfield MS, Spotnitz WD. Fibrin sealant in thoracic surgery. Pulmonary applications, including management of bronchoplueral fistula. Chest Surg Clin N Am 1996; 6(3): 567.
    • (1996) Chest Surg Clin N Am , vol.6 , Issue.3 , pp. 567
    • Bayfield, M.S.1    Spotnitz, W.D.2
  • 5
    • 0030725293 scopus 로고    scopus 로고
    • Endoscopic fibrin sealant injection: A novel method of closing a refractory gastrocutaneous fistula
    • Shand A, Pendlebury J, Reading S, et al. Endoscopic fibrin sealant injection: a novel method of closing a refractory gastrocutaneous fistula. Gastrointestin Endosc 1997; 46(4): 357.
    • (1997) Gastrointestin Endosc , vol.46 , Issue.4 , pp. 357
    • Shand, A.1    Pendlebury, J.2    Reading, S.3
  • 6
    • 0036023107 scopus 로고    scopus 로고
    • Endoscopic treatment of post-operative fistulas resistant to conservative management using biological fibrin glue
    • Rabago LR, Ventosa N, Castro JL, et al. Endoscopic treatment of post-operative fistulas resistant to conservative management using biological fibrin glue. Endoscopy 2002; 34(8): 632.
    • (2002) Endoscopy , vol.34 , Issue.8 , pp. 632
    • Rabago, L.R.1    Ventosa, N.2    Castro, J.L.3
  • 7
    • 3142739590 scopus 로고    scopus 로고
    • Results after endoscopic treatment of post-operative upper gastrointestinal fistulas and leaks using combined vicryl plug and fibrin glue
    • Truong S, Bohm G, Klinge U, et al. Results after endoscopic treatment of post-operative upper gastrointestinal fistulas and leaks using combined vicryl plug and fibrin glue. Surg Endosc 2004; 18(7): 1105.
    • (2004) Surg Endosc , vol.18 , Issue.7 , pp. 1105
    • Truong, S.1    Bohm, G.2    Klinge, U.3
  • 8
    • 0030054237 scopus 로고    scopus 로고
    • Randomized trial of fibrin tissue glue for low output enterocutaneous fistulas
    • Hwang TL, Chen MF. Randomized trial of fibrin tissue glue for low output enterocutaneous fistulas. Brit J Surg 1996; 83(1): 112.
    • (1996) Brit J Surg , vol.83 , Issue.1 , pp. 112
    • Hwang, T.L.1    Chen, M.F.2
  • 9
    • 0029973145 scopus 로고    scopus 로고
    • Rapid en bloc technique for pancreas-liver procurement. Improved early liver function
    • Imagawa DK, Olthoff KM, Yersiz H, et al. Rapid en bloc technique for pancreas-liver procurement. Improved early liver function. Transplantation 1996; 61(11): 1605.
    • (1996) Transplantation , vol.61 , Issue.11 , pp. 1605
    • Imagawa, D.K.1    Olthoff, K.M.2    Yersiz, H.3
  • 10
    • 2342622650 scopus 로고    scopus 로고
    • Comparison of histidine-tryptophan-ketoglutarate solution and University of Wisconsin solution for organ preservation in clinical pancreas transplantation
    • Fridell JA, Agarwal A, Milgrom ML, et al. Comparison of histidine-tryptophan-ketoglutarate solution and University of Wisconsin solution for organ preservation in clinical pancreas transplantation. Transplantation 2004; 77(8): 1304.
    • (2004) Transplantation , vol.77 , Issue.8 , pp. 1304
    • Fridell, J.A.1    Agarwal, A.2    Milgrom, M.L.3
  • 11
    • 27844597202 scopus 로고    scopus 로고
    • Follow-up experience using histidine-tryptophan ketoglutarate solution in clinical pancreas transplantation
    • Agarwal A, Murdock P, Pescovitz MD, et al. Follow-up experience using histidine-tryptophan ketoglutarate solution in clinical pancreas transplantation. Transplant Proc 2005; 37(8): 3523.
    • (2005) Transplant Proc , vol.37 , Issue.8 , pp. 3523
    • Agarwal, A.1    Murdock, P.2    Pescovitz, M.D.3
  • 12
    • 6344276549 scopus 로고    scopus 로고
    • Ipsilateral placement of simultaneous pancreas and kidney allografts
    • Fridell JA, Shah A, Milgrom M, et al. Ipsilateral placement of simultaneous pancreas and kidney allografts. Transplantation 2004; 78(7): 1074.
    • (2004) Transplantation , vol.78 , Issue.7 , pp. 1074
    • Fridell, J.A.1    Shah, A.2    Milgrom, M.3
  • 13
    • 2142640802 scopus 로고    scopus 로고
    • Use of the EEA Circular stapler for creation of the duodenoenterostomy for enteric drainage of the pancreas allograft
    • Fridell JA, Milgrom M, Henson S, Pescovitz MD. Use of the EEA Circular stapler for creation of the duodenoenterostomy for enteric drainage of the pancreas allograft. J Am Coll Surg 2004; 198(3): 494.
    • (2004) J Am Coll Surg , vol.198 , Issue.3 , pp. 494
    • Fridell, J.A.1    Milgrom, M.2    Henson, S.3    Pescovitz, M.D.4
  • 14
    • 0037180936 scopus 로고    scopus 로고
    • A prospective study of rapid corticosteroid elimination in simultaneous pancreas-kidney transplantation: Comparison of two maintenance immunosuppression protocols: Tacrolimus/mycophenolate mofetil versus tacrolimus/sirolimus
    • Kaufman DB, Leventhal JR, Koffron AJ, et al. A prospective study of rapid corticosteroid elimination in simultaneous pancreas-kidney transplantation: comparison of two maintenance immunosuppression protocols: tacrolimus/ mycophenolate mofetil versus tacrolimus/sirolimus. Transplantation 2002; 73(2): 169.
    • (2002) Transplantation , vol.73 , Issue.2 , pp. 169
    • Kaufman, D.B.1    Leventhal, J.R.2    Koffron, A.J.3
  • 15
    • 0027791739 scopus 로고
    • Surgical complications after simultaneous pancreas-kidney transplant with bladder drainage
    • Eckhoff DE, Sollinger HW. Surgical complications after simultaneous pancreas-kidney transplant with bladder drainage. Clin Transplant 1993; 185.
    • (1993) Clin Transplant , vol.185
    • Eckhoff, D.E.1    Sollinger, H.W.2
  • 16
    • 0027434931 scopus 로고
    • Incidence, management and significance of surgical complications after pancreatic transplantation
    • Douzdjian V, Abecassis MM, Cooper JL, et al. Incidence, management and significance of surgical complications after pancreatic transplantation. Surg Gynecol Obstetr 1993; 177(5): 451.
    • (1993) Surg Gynecol Obstetr , vol.177 , Issue.5 , pp. 451
    • Douzdjian, V.1    Abecassis, M.M.2    Cooper, J.L.3
  • 17
    • 0027105192 scopus 로고
    • Surgical complications in solitary pancreas and combined pancreas-kidney transplantations
    • Ozaki CF, Stratta RJ, Taylor RJ, et al. Surgical complications in solitary pancreas and combined pancreas-kidney transplantations. Am J Surg 1992; 164(5): 546.
    • (1992) Am J Surg , vol.164 , Issue.5 , pp. 546
    • Ozaki, C.F.1    Stratta, R.J.2    Taylor, R.J.3
  • 18
    • 0022260166 scopus 로고
    • Fibrin seal: The state of the art
    • Matras H. Fibrin seal: the state of the art. J Oral Maxillofacial Surg 1985; 43(8): 605.
    • (1985) J Oral Maxillofacial Surg , vol.43 , Issue.8 , pp. 605
    • Matras, H.1
  • 19
    • 0034810587 scopus 로고    scopus 로고
    • Tissue sealing
    • Morikawa T. Tissue sealing. Am J Surg 2001; 182(2 supplement): 29s.
    • (2001) Am J Surg , vol.182 , Issue.2 SUPPL.
    • Morikawa, T.1
  • 20
    • 0033135501 scopus 로고    scopus 로고
    • Percutaneous management of a high output duodenal fistula after pancreas transplantation using occluding coiled embolus and fibrin sealant
    • Padillo FJ, Regueiro JC, Canis M, et al. Percutaneous management of a high output duodenal fistula after pancreas transplantation using occluding coiled embolus and fibrin sealant. Transplant Proc 1999; 31(3): 1715.
    • (1999) Transplant Proc , vol.31 , Issue.3 , pp. 1715
    • Padillo, F.J.1    Regueiro, J.C.2    Canis, M.3
  • 21
    • 0031298312 scopus 로고    scopus 로고
    • Diagnosis, management, and outcome of late duodenal complications in portal-enteric pancreas transplantation: Case reports
    • Nymann T, Shokouh-Amiri MH, Elmer DS, et al. Diagnosis, management, and outcome of late duodenal complications in portal-enteric pancreas transplantation: case reports. J Am Coll Surg 1997; 185(6): 560.
    • (1997) J Am Coll Surg , vol.185 , Issue.6 , pp. 560
    • Nymann, T.1    Shokouh-Amiri, M.H.2    Elmer, D.S.3
  • 22
    • 0025304879 scopus 로고
    • Management of delayed complications of the duodenal loop in whole organ pancreatic duodenal transplantation
    • Mital VK, Toledo-Pereyra LH. Management of delayed complications of the duodenal loop in whole organ pancreatic duodenal transplantation. Transplant Proc 1990; 22(2): 580.
    • (1990) Transplant Proc , vol.22 , Issue.2 , pp. 580
    • Mital, V.K.1    Toledo-Pereyra, L.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.