Volumn 154, Issue 3, 2006, Pages 389-395

Measurement of exercise ventilation by a portable respiratory inductive plethysmograph

Author keywords

Breathing pattern; Non invasive respiratory monitoring; Pneumotachograph; Sub maximal exercise

Indexed keywords

ABDOMEN; ADULT; ARTICLE; BREATHING PATTERN; BREATHING RATE; CLOTHING; CONTROLLED STUDY; EXERCISE; EXERCISE INTENSITY; EXHAUSTION; HUMAN; INTERMETHOD COMPARISON; LUNG MINUTE VOLUME; LUNG VENTILATION; MALE; NORMAL HUMAN; PLETHYSMOGRAPH; PNEUMOTACHYGRAPHY; PRIORITY JOURNAL; RESPIRATORY INDUCTIVE PLETHYSMOGRAPH; REST; RUNNING; SENSOR; STATISTICAL ANALYSIS; STATISTICAL SIGNIFICANCE; THORAX; TIDAL VOLUME; TREADMILL EXERCISE; WALKING;

EID: 33750977585     PISSN: 15699048     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resp.2006.01.010     Document Type: Article
Times cited : (61)

References (13)
  • 2
    • 0036644465 scopus 로고    scopus 로고
    • ATS statement: guidelines for the six-minute walk test
    • ATS. ATS statement: guidelines for the six-minute walk test. Am .J. Respir. Crit. Care Med. 166 (2002) 111-117
    • (2002) Am .J. Respir. Crit. Care Med. , vol.166 , pp. 111-117
    • ATS1
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0028935423 scopus 로고
    • Effect of mouthpiece breathing on cardiorespiratory response to intense exercise
    • Bloch K.E., Barandun J., and Sackner M.A. Effect of mouthpiece breathing on cardiorespiratory response to intense exercise. Am. J. Respir. Crit. Care Med. 151 (1995) 1087-1092
    • (1995) Am. J. Respir. Crit. Care Med. , vol.151 , pp. 1087-1092
    • Bloch, K.E.1    Barandun, J.2    Sackner, M.A.3
  • 5
    • 0028111749 scopus 로고
    • Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise
    • Caretti D.M., Pullen P.V., Premo L.A., and Kuhlmann W.D. Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise. Am. Ind. Hyg. Assoc. J. 55 (1994) 918-923
    • (1994) Am. Ind. Hyg. Assoc. J. , vol.55 , pp. 918-923
    • Caretti, D.M.1    Pullen, P.V.2    Premo, L.A.3    Kuhlmann, W.D.4
  • 7
    • 24944542258 scopus 로고    scopus 로고
    • Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph
    • Clarenbach C.F., Senn O., Brack T., Kohler M., and Bloch K.E. Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph. Chest 128 (2005) 1282-1290
    • (2005) Chest , vol.128 , pp. 1282-1290
    • Clarenbach, C.F.1    Senn, O.2    Brack, T.3    Kohler, M.4    Bloch, K.E.5
  • 8
    • 33750979706 scopus 로고    scopus 로고
    • CSEP. Physical Activity Readiness Questionnaire (PAR-Q): Available from the Canadian Society for Exercise Physiology (CSEP); http://www.csep.ca/, 2002.
  • 9
    • 0015384501 scopus 로고
    • Changes in tidal volume, frequency, and ventilation induced by their measurement
    • Gilbert R., Auchincloss Jr. J.H., Brodsky J., and Boden W. Changes in tidal volume, frequency, and ventilation induced by their measurement. J. Appl. Physiol. 33 (1972) 252-254
    • (1972) J. Appl. Physiol. , vol.33 , pp. 252-254
    • Gilbert, R.1    Auchincloss Jr., J.H.2    Brodsky, J.3    Boden, W.4
  • 10
    • 0036041746 scopus 로고    scopus 로고
    • Tidal volume and respiratory timing derived from a portable ventilation monitor
    • McCool F.D., Wang J., and Ebi K.L. Tidal volume and respiratory timing derived from a portable ventilation monitor. Chest 122 (2002) 684-691
    • (2002) Chest , vol.122 , pp. 684-691
    • McCool, F.D.1    Wang, J.2    Ebi, K.L.3
  • 11
    • 0000848736 scopus 로고
    • Control of respiratory frequency
    • Mead J. Control of respiratory frequency. J. Appl. Physiol. 15 (1960) 325-336
    • (1960) J. Appl. Physiol. , vol.15 , pp. 325-336
    • Mead, J.1
  • 12
    • 0022357356 scopus 로고
    • Separation of factors responsible for change in breathing pattern induced by instrumentation
    • Perez W., and Tobin M.J. Separation of factors responsible for change in breathing pattern induced by instrumentation. J. Appl. Physiol. 59 (1985) 1515-1520
    • (1985) J. Appl. Physiol. , vol.59 , pp. 1515-1520
    • Perez, W.1    Tobin, M.J.2
  • 13
    • 0026068230 scopus 로고
    • Accuracy of respiratory inductive plethysmograph in measuring tidal volume during sleep
    • Whyte K.F., Gugger M., Gould G.A., Molloy J., Wraith P.K., and Douglas N.J. Accuracy of respiratory inductive plethysmograph in measuring tidal volume during sleep. J. Appl. Physiol. 71 (1991) 1866-1871
    • (1991) J. Appl. Physiol. , vol.71 , pp. 1866-1871
    • Whyte, K.F.1    Gugger, M.2    Gould, G.A.3    Molloy, J.4    Wraith, P.K.5    Douglas, N.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.