메뉴 건너뛰기




Volumn 47, Issue 11, 2006, Pages 967-970

Measurement of cardiac output using Physio Flow® with different positions of electrode placement

Author keywords

Electrode placements; Impedance; Non invasive cardiac output monitoring; Physio Flow

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORRELATION ANALYSIS; CROSSOVER PROCEDURE; ELECTRODE; FEMALE; HEART OUTPUT MEASUREMENT; HEART STROKE VOLUME; HUMAN; IMPEDANCE CARDIOGRAPHY; MALE; NON INVASIVE PROCEDURE; REGRESSION ANALYSIS;

EID: 33750971733     PISSN: 00375675     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (24)

References (12)
  • 1
    • 0032900236 scopus 로고    scopus 로고
    • Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: Conventional techniques
    • Warburton D, Haykowsky M, Quinney H, Humen DP, Teo KK. Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: conventional techniques. Sports Med 1999; 27:23-41.
    • (1999) Sports Med , vol.27 , pp. 23-41
    • Warburton, D.1    Haykowsky, M.2    Quinney, H.3    Humen, D.P.4    Teo, K.K.5
  • 2
    • 0017234519 scopus 로고
    • Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization: Fick vs. dye cardiac outputs
    • Reddy P, Curtiss E, Bell B, et al. Determinants of variation between Fick and indicator dilution estimates of cardiac output during diagnostic catheterization: Fick vs. dye cardiac outputs. J Lab Clin Med 1976; 87:568-76.
    • (1976) J Lab Clin Med , vol.87 , pp. 568-576
    • Reddy, P.1    Curtiss, E.2    Bell, B.3
  • 5
    • 0029026354 scopus 로고
    • A review of impedance cardiography
    • Jensen L, Yakimets J, Teo KK. A review of impedance cardiography. Heart Lung 1995; 24:183-93.
    • (1995) Heart Lung , vol.24 , pp. 183-193
    • Jensen, L.1    Yakimets, J.2    Teo, K.K.3
  • 6
    • 0035014171 scopus 로고    scopus 로고
    • New ambulatory impedance cardiograph validated against the Minnesota Impedance Cardiograph
    • Nakonezny P, Kowalewski RB, Ernst JM, et al. New ambulatory impedance cardiograph validated against the Minnesota Impedance Cardiograph. Psychophysiology 2001; 38:465-73.
    • (2001) Psychophysiology , vol.38 , pp. 465-473
    • Nakonezny, P.1    Kowalewski, R.B.2    Ernst, J.M.3
  • 7
    • 0000251895 scopus 로고
    • Hemodynamic monitoring by impedance cardiography with an improved signal processing technique
    • Wang X, Van de Water JM, Sun H, et al. Hemodynamic monitoring by impedance cardiography with an improved signal processing technique. Proc IEEE Eng Med Biol 1993; 15:699-700.
    • (1993) Proc IEEE Eng Med Biol , vol.15 , pp. 699-700
    • Wang, X.1    Van De Water, J.M.2    Sun, H.3
  • 8
    • 0030910532 scopus 로고    scopus 로고
    • Continuous intraoperative noninvasive cardiac output monitoring using a new thoracic bioimpedance device
    • Thangathurai D, Charbonnet C, Roessler P, et al. Continuous intraoperative noninvasive cardiac output monitoring using a new thoracic bioimpedance device. J Cardiothorac Vasc Anesth 1997; 11:440-4.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 440-444
    • Thangathurai, D.1    Charbonnet, C.2    Roessler, P.3
  • 9
    • 0031016222 scopus 로고    scopus 로고
    • Impedance cardiography accurately measures cardiac output during exercise in children with cystic fibrosis
    • Pianosi PT. Impedance cardiography accurately measures cardiac output during exercise in children with cystic fibrosis. Chest 1997; 111:333-7.
    • (1997) Chest , vol.111 , pp. 333-337
    • Pianosi, P.T.1
  • 10
    • 0031008509 scopus 로고    scopus 로고
    • Comment
    • Comment in: Chest 1997; 111:1786.
    • (1997) Chest , vol.111 , pp. 1786
  • 11
    • 0033891415 scopus 로고    scopus 로고
    • A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: Comparison with the "direct" Pick method
    • Charloux A, Londorfer-Wolf E, Ruddy R, et al. A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the "direct" Pick method. Eur J Appl Physiol 2000; 82:313-20.
    • (2000) Eur J Appl Physiol , vol.82 , pp. 313-320
    • Charloux, A.1    Londorfer-Wolf, E.2    Ruddy, R.3
  • 12
    • 0034885307 scopus 로고    scopus 로고
    • Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device
    • Richard R, Lonsdorfer-Wolf E, Charloux A, et al. Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device. Eur J Appl Physiol 2001; 85:202-7.
    • (2001) Eur J Appl Physiol , vol.85 , pp. 202-207
    • Richard, R.1    Lonsdorfer-Wolf, E.2    Charloux, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.