메뉴 건너뛰기




Volumn 19, Issue 6, 2006, Pages 551-556

Utility of static pressure ratio recording during angioplasty of arteriovenous graft stenosis

Author keywords

[No Author keywords available]

Indexed keywords


EID: 33750957716     PISSN: 08940959     EISSN: 1525139X     Source Type: Journal    
DOI: 10.1111/j.1525-139X.2006.00221.x     Document Type: Article
Times cited : (15)

References (18)
  • 2
    • 0035046173 scopus 로고    scopus 로고
    • Flow in hemodialysis grafts after angioplasty: Do radiologic criteria predict success?
    • Ahya SN, Windus DW, Vesely TM: Flow in hemodialysis grafts after angioplasty: Do radiologic criteria predict success? Kidney Int 59:1974-1978, 2001
    • (2001) Kidney Int , vol.59 , pp. 1974-1978
    • Ahya, S.N.1    Windus, D.W.2    Vesely, T.M.3
  • 3
    • 0011484179 scopus 로고    scopus 로고
    • Inflow stenosis (S) of AV hemodialysis access can be found more frequently in patients (p) monitored with regular intra-access flow (AF) measurements
    • [Abstract]
    • Levine MI, Wallach JD: Inflow stenosis (S) of AV hemodialysis access can be found more frequently in patients (p) monitored with regular intra-access flow (AF) measurements. J Am Soc Nephrol 10:209, 1999 [Abstract].
    • (1999) J Am Soc Nephrol , vol.10 , pp. 209
    • Levine, M.I.1    Wallach, J.D.2
  • 4
    • 4243280087 scopus 로고    scopus 로고
    • Inflow (IF) stenosis (S), and coexisting (CoX) if and outflow (OF) S of arteriovenous access (AV) occur frequently and can be detected measuring static pressure (SP) during percutaneous interventions
    • [Abstract]
    • Levine MI, Asif A, Rismeyer AE, Wallach J: Inflow (IF) stenosis (S), and coexisting (CoX) IF and outflow (OF) S of arteriovenous access (AV) occur frequently and can be detected measuring static pressure (SP) during percutaneous interventions. J Am Soc Nephrol 13:234, 2002 [Abstract].
    • (2002) J Am Soc Nephrol , vol.13 , pp. 234
    • Levine, M.I.1    Asif, A.2    Rismeyer, A.E.3    Wallach, J.4
  • 5
    • 0029048657 scopus 로고
    • Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis
    • Besarab A, Sullivan KL, Ross RP, Mortiz MJ: Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. Kidney Int 47:1364-1373, 1995
    • (1995) Kidney Int , vol.47 , pp. 1364-1373
    • Besarab, A.1    Sullivan, K.L.2    Ross, R.P.3    Mortiz, M.J.4
  • 9
    • 0034821259 scopus 로고    scopus 로고
    • Effects of systemic hemodynamics on flow within vascular accesses used for hemodialysis
    • Besarab A, Lubkowski T, Vu A, Aslam A, Frinak S: Effects of systemic hemodynamics on flow within vascular accesses used for hemodialysis. ASAIO J 47:501-506, 2001
    • (2001) ASAIO J , vol.47 , pp. 501-506
    • Besarab, A.1    Lubkowski, T.2    Vu, A.3    Aslam, A.4    Frinak, S.5
  • 10
    • 0031239513 scopus 로고    scopus 로고
    • Detection of access strictures and outlet stenoses in vascular accesses. Which test is best?
    • Besarab A, Lubkowski T, Frinak S, Ramanathan S, Escobar F: Detection of access strictures and outlet stenoses in vascular accesses. Which test is best? ASAIO J 43:M543-M547, 1997
    • (1997) ASAIO J , vol.43
    • Besarab, A.1    Lubkowski, T.2    Frinak, S.3    Ramanathan, S.4    Escobar, F.5
  • 12
    • 0035228229 scopus 로고    scopus 로고
    • NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: Update 2000
    • NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: update 2000. Am J Kidney Dis 37(Suppl. 1):S137-S181, 2001
    • (2001) Am J Kidney Dis , vol.37 , Issue.SUPPL. 1
  • 13
    • 0026484859 scopus 로고
    • Percutaneous transvenous angioplasty in the treatment of vascular access stenosis
    • Beathard GA: Percutaneous transvenous angioplasty in the treatment of vascular access stenosis. Kidney Int 42:1390-1397, 1992
    • (1992) Kidney Int , vol.42 , pp. 1390-1397
    • Beathard, G.A.1
  • 14
    • 0033643668 scopus 로고    scopus 로고
    • Access monitoring methods
    • Besarab A: Access monitoring methods. Blood Purif 18:255-259, 2000
    • (2000) Blood Purif , vol.18 , pp. 255-259
    • Besarab, A.1
  • 15
    • 4444355635 scopus 로고    scopus 로고
    • Pressure measurements in the surveillance of vascular accesses
    • Gray R (ed). Philadelphia, PA: Lippencott, Williams & Wilkins
    • Besarab A, Frinak S, Aslam M: Pressure measurements in the surveillance of vascular accesses. In: Gray R (ed). A Multidisciplinary Approach for Hemodialysis Access. Philadelphia, PA: Lippencott, Williams & Wilkins, 2002:137-150
    • (2002) A Multidisciplinary Approach for Hemodialysis Access , pp. 137-150
    • Besarab, A.1    Frinak, S.2    Aslam, M.3
  • 16
    • 0036526671 scopus 로고    scopus 로고
    • Endovascular intervention for the failing vascular access
    • Vesely TM: Endovascular intervention for the failing vascular access. Adv Ren Replace Ther 9:99-108, 2002
    • (2002) Adv Ren Replace Ther , vol.9 , pp. 99-108
    • Vesely, T.M.1
  • 18
    • 0036218217 scopus 로고    scopus 로고
    • Use of a catheter-based system to measure blood flow in hemodialysis grafts during angioplasty procedures
    • Vesely TM, Gherardini D, Gleed RD, Kislukhin V, Krivitski NM: Use of a catheter-based system to measure blood flow in hemodialysis grafts during angioplasty procedures. J Vasc Interv Radiol 13:371-378, 2002
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 371-378
    • Vesely, T.M.1    Gherardini, D.2    Gleed, R.D.3    Kislukhin, V.4    Krivitski, N.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.