메뉴 건너뛰기




Volumn 30, Issue 6, 2006, Pages 873-876

Vacuum-assisted apical suction devices induce passive electrical changes consistent with myocardial ischemia during off-pump coronary artery bypass graft surgery

Author keywords

Apical suction devices; Myocardial electrical impedance; Myocardial ischemia; Off pump coronary artery bypass surgery

Indexed keywords

ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY DISEASE; HEART MUSCLE ISCHEMIA; HUMAN; IMPEDANCE; LEFT ANTERIOR DESCENDING CORONARY ARTERY; OFF PUMP CORONARY SURGERY; PRIORITY JOURNAL; REVASCULARIZATION; ST SEGMENT; VACUUM;

EID: 33750948822     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2006.09.005     Document Type: Article
Times cited : (7)

References (15)
  • 2
    • 2942735498 scopus 로고    scopus 로고
    • Will off-pump coronary artery surgery replace conventional coronary artery surgery?
    • Raja S.G., and Dreyfus G.D. Will off-pump coronary artery surgery replace conventional coronary artery surgery?. J Royal Soc Med 97 (2004) 275-278
    • (2004) J Royal Soc Med , vol.97 , pp. 275-278
    • Raja, S.G.1    Dreyfus, G.D.2
  • 3
    • 0034794962 scopus 로고    scopus 로고
    • Coronary artery exposure in off-pump cabg: a word of caution
    • discussion [245-6]
    • D'Ancona G., Karamanoukian H., Kawaguchi A., and Bergsland J. Coronary artery exposure in off-pump cabg: a word of caution. Heart Surg Forum 4 3 (2001) 243-245 discussion [245-6]
    • (2001) Heart Surg Forum , vol.4 , Issue.3 , pp. 243-245
    • D'Ancona, G.1    Karamanoukian, H.2    Kawaguchi, A.3    Bergsland, J.4
  • 6
    • 29544446755 scopus 로고    scopus 로고
    • Early time course of myocardial electrical impedance during acute coronary artery occlusion in pigs, dogs, and humans
    • del Rio C.L., McConnell P.I., Clymer B.D., Dzwonczyk R., Michler R.E., Billman G.E., and Howie M.B. Early time course of myocardial electrical impedance during acute coronary artery occlusion in pigs, dogs, and humans. J Appl Physiol 99 4 (2005) 1576-1581
    • (2005) J Appl Physiol , vol.99 , Issue.4 , pp. 1576-1581
    • del Rio, C.L.1    McConnell, P.I.2    Clymer, B.D.3    Dzwonczyk, R.4    Michler, R.E.5    Billman, G.E.6    Howie, M.B.7
  • 7
    • 0035169389 scopus 로고    scopus 로고
    • An evaluation of a new two-electrode myocardial electrical pedance monitor for detecting myocardial ischemia
    • Howie M.B., Dzwonczyk R., and McSweeney T.D. An evaluation of a new two-electrode myocardial electrical pedance monitor for detecting myocardial ischemia. Anesth Analg 92 (2001) 12-18
    • (2001) Anesth Analg , vol.92 , pp. 12-18
    • Howie, M.B.1    Dzwonczyk, R.2    McSweeney, T.D.3
  • 8
    • 0029666022 scopus 로고    scopus 로고
    • 2+, intercellular electrical coupling, and mechanical activity in ischemic rabbit papillary muscle. Effects of preconditioning and metabolic blockade
    • 2+, intercellular electrical coupling, and mechanical activity in ischemic rabbit papillary muscle. Effects of preconditioning and metabolic blockade. Circ Res 79 2 (1996) 237-246
    • (1996) Circ Res , vol.79 , Issue.2 , pp. 237-246
    • Dekker, L.R.1    Fiolet, J.W.2    VanBavel, E.3    Coronel, R.4    Opthof, T.5    Spaan, J.A.6    Janse, M.J.7
  • 9
    • 28444483979 scopus 로고    scopus 로고
    • Very low cost real-time recording of intra-operative cardio-respiratory data over the internet: a definite reality?
    • del Rio C.L., and Howie M.B. Very low cost real-time recording of intra-operative cardio-respiratory data over the internet: a definite reality?. Anesthesiology 95 (2001) A520
    • (2001) Anesthesiology , vol.95
    • del Rio, C.L.1    Howie, M.B.2
  • 11
    • 85025492781 scopus 로고    scopus 로고
    • Anonymous. Guidelines and indications for coronary artery bypass graft surgery. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Coronary Artery Bypass Graft Surgery). J Am Coll Cardiol 1991;17(3):543-89.
  • 12
    • 0026591910 scopus 로고
    • A comparison of methods for the detection of myocardial ischemia during noncardiac surgery: automated ST-segment analysis systems, electrocardiography and transesophageal echocardiography
    • Ellis J.E., Shah M.N., Briller J.E., Roizen M.F., Aronson S., and Feinstein S.B. A comparison of methods for the detection of myocardial ischemia during noncardiac surgery: automated ST-segment analysis systems, electrocardiography and transesophageal echocardiography. Anesth Analg 75 (1992) 764-772
    • (1992) Anesth Analg , vol.75 , pp. 764-772
    • Ellis, J.E.1    Shah, M.N.2    Briller, J.E.3    Roizen, M.F.4    Aronson, S.5    Feinstein, S.B.6
  • 13
    • 0029878908 scopus 로고    scopus 로고
    • Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device ('Octopus')
    • Borst C., Jansen E.W., Tulleken C.A., Grundeman P.F., Mansvelt Beck H.J., van Dongen J.W., Hodde K.C., and Bredee J.J. Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device ('Octopus'). J Am Coll Cardiol 27 6 (1996) 1356-1364
    • (1996) J Am Coll Cardiol , vol.27 , Issue.6 , pp. 1356-1364
    • Borst, C.1    Jansen, E.W.2    Tulleken, C.A.3    Grundeman, P.F.4    Mansvelt Beck, H.J.5    van Dongen, J.W.6    Hodde, K.C.7    Bredee, J.J.8
  • 15
    • 9344257286 scopus 로고    scopus 로고
    • Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device
    • Chang W.I., Kim K.B., Kim J.H., Ham B.M., and Kim Y.L. Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device. Ann Thorac Surg 78 6 (2004) 2057-2062
    • (2004) Ann Thorac Surg , vol.78 , Issue.6 , pp. 2057-2062
    • Chang, W.I.1    Kim, K.B.2    Kim, J.H.3    Ham, B.M.4    Kim, Y.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.