메뉴 건너뛰기




Volumn 68, Issue 5, 2006, Pages 727-734

Development of a reexpandable covered stent for children

Author keywords

Dipping method; Palmaz stent; Polyurethane membrane; Reexpandable covered stent

Indexed keywords

POLYURETHAN;

EID: 33750877993     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.20788     Document Type: Article
Times cited : (7)

References (22)
  • 2
    • 0031888362 scopus 로고    scopus 로고
    • Pediatric therapeutic cardiac catheterization: A statement for healthcare professionals from the council on cardiovascular disease in the young, American Heart Association
    • Allen HD, Beekman RH III, Garson A Jr, Hijazi ZM, Mullins C, O'Laughlin MP, Taubert KA. Pediatric therapeutic cardiac catheterization: A statement for healthcare professionals from the council on cardiovascular disease in the young, American Heart Association. Circulation 1998;97:609-625.
    • (1998) Circulation , vol.97 , pp. 609-625
    • Allen, H.D.1    Beekman III, R.H.2    Garson Jr., A.3    Hijazi, Z.M.4    Mullins, C.5    O'Laughlin, M.P.6    Taubert, K.A.7
  • 6
    • 0034842677 scopus 로고    scopus 로고
    • Stenting of coarctation of the aorta
    • Cheatham JP. Stenting of coarctation of the aorta. Catheter Cardiovasc Interv 2001;54:112-125.
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 112-125
    • Cheatham, J.P.1
  • 7
    • 0036109735 scopus 로고    scopus 로고
    • Pediatric cardiac catheterization
    • Rocchini AP. Pediatric cardiac catheterization. Curr Opin Cardiol 2002;17:283-288.
    • (2002) Curr Opin Cardiol , vol.17 , pp. 283-288
    • Rocchini, A.P.1
  • 8
    • 0037218933 scopus 로고    scopus 로고
    • Coarctation of the aorta in adults: Do we need surgeons?
    • Mullen MJ. Coarctation of the aorta in adults: Do we need surgeons? Heart 2003;89:3-5.
    • (2003) Heart , vol.89 , pp. 3-5
    • Mullen, M.J.1
  • 9
    • 0030778550 scopus 로고    scopus 로고
    • Use of a self-expanding vascular occluder for embolization during endovascular aortic aneurysm repair
    • Kato N, Semba CP, Dake MD. Use of a self-expanding vascular occluder for embolization during endovascular aortic aneurysm repair. J Vase Interv Radiol 1997;8:27-33.
    • (1997) J Vase Interv Radiol , vol.8 , pp. 27-33
    • Kato, N.1    Semba, C.P.2    Dake, M.D.3
  • 13
    • 0023875003 scopus 로고
    • Balloon-expandable intravascular stent
    • Palmaz JC. Balloon-expandable intravascular stent. AJR Am J Roentgenol 1988;150:1263-1269.
    • (1988) AJR Am J Roentgenol , vol.150 , pp. 1263-1269
    • Palmaz, J.C.1
  • 15
    • 0026042559 scopus 로고
    • Percutaneous implantation of a balloon-expandable endoprosthesis for pulmonary artery stenosis: An experimental study
    • Benson LN, Hamilton F, Dasmahapatra H, Rabinowitch M, Coles JC, Freedom RM. Percutaneous implantation of a balloon-expandable endoprosthesis for pulmonary artery stenosis: An experimental study. J Am Coll Cardiol 1991;18:1303-1308.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1303-1308
    • Benson, L.N.1    Hamilton, F.2    Dasmahapatra, H.3    Rabinowitch, M.4    Coles, J.C.5    Freedom, R.M.6
  • 17
    • 0026530322 scopus 로고
    • Use of balloon-expandable stents to treat experimental peripheral pulmonary artery and superior vena caval stenosis: Preliminary experience
    • Rocchini AP, Meliones JN, Beekman RH, Moorehead C, London M. Use of balloon-expandable stents to treat experimental peripheral pulmonary artery and superior vena caval stenosis: Preliminary experience. Pediatr Cardiol 1992;13:92-96.
    • (1992) Pediatr Cardiol , vol.13 , pp. 92-96
    • Rocchini, A.P.1    Meliones, J.N.2    Beekman, R.H.3    Moorehead, C.4    London, M.5
  • 21
    • 0029147365 scopus 로고
    • Repeat dilation of intravascular stents in congenital heart defects
    • Ing FF, Grifka RG, Nihill MR, Mullins CE. Repeat dilation of intravascular stents in congenital heart defects. Circulation 1995; 92:893-897.
    • (1995) Circulation , vol.92 , pp. 893-897
    • Ing, F.F.1    Grifka, R.G.2    Nihill, M.R.3    Mullins, C.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.