메뉴 건너뛰기




Volumn 29, Issue 4, 2006, Pages 168-175

Fabrication of low-field water-cooled resistive magnets for small animal magnetic resonance imaging

Author keywords

Construction technique; Magnetic resonance imaging; Resistive magnets

Indexed keywords


EID: 33750877511     PISSN: 15525031     EISSN: 1552504X     Source Type: Journal    
DOI: 10.1002/cmr.b.20072     Document Type: Article
Times cited : (4)

References (17)
  • 2
    • 0008429580 scopus 로고    scopus 로고
    • Compact low field magnetic resonance imaging magnet: Design and optimization
    • Sciandrone M, Placidi G, Testa L, Sotgiu A. 2000. Compact low field magnetic resonance imaging magnet: design and optimization. Rev Sci Instrum 71:1534-1538.
    • (2000) Rev Sci Instrum , vol.71 , pp. 1534-1538
    • Sciandrone, M.1    Placidi, G.2    Testa, L.3    Sotgiu, A.4
  • 4
    • 12844279813 scopus 로고    scopus 로고
    • Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs
    • Parra-Robles J, Cross AR, Santyr GE. 2005. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs. Med Phys 32:221-229.
    • (2005) Med Phys , vol.32 , pp. 221-229
    • Parra-Robles, J.1    Cross, A.R.2    Santyr, G.E.3
  • 6
    • 79956054321 scopus 로고    scopus 로고
    • Low readout field magnetic resonance imaging of hyperpolarized xenon and water in a single system
    • Shao W, Guodong W, Fuzesy R, Hughes EW, Chronik BA, Scott GC, et al. 2002. Low readout field magnetic resonance imaging of hyperpolarized xenon and water in a single system. Appl Phys Lett 80:2032-2034.
    • (2002) Appl Phys Lett , vol.80 , pp. 2032-2034
    • Shao, W.1    Guodong, W.2    Fuzesy, R.3    Hughes, E.W.4    Chronik, B.A.5    Scott, G.C.6
  • 9
    • 0031813421 scopus 로고    scopus 로고
    • Design, construction and use of a large-sample field-cycled PEDRI imager
    • Lurie DJ, Foster MA, Yeung D, Hutchison JMS. 1998. Design, construction and use of a large-sample field-cycled PEDRI imager. Phys Med Biol 43:1877-1886.
    • (1998) Phys Med Biol , vol.43 , pp. 1877-1886
    • Lurie, D.J.1    Foster, M.A.2    Yeung, D.3    Hutchison, J.M.S.4
  • 13
    • 0027200495 scopus 로고
    • Novel approaches to low-cost MRI
    • Macovski A, Conolly S. 1993. Novel approaches to low-cost MRI. Magn Reson Med 30:221-230.
    • (1993) Magn Reson Med , vol.30 , pp. 221-230
    • Macovski, A.1    Conolly, S.2
  • 15
    • 0035440480 scopus 로고    scopus 로고
    • Optimal design and construction of a lightweight minimum-power solenoid magnet
    • Morgan PN. 2001. Optimal design and construction of a lightweight minimum-power solenoid magnet. IEEE Trans Magn 37:3814-3817.
    • (2001) IEEE Trans Magn , vol.37 , pp. 3814-3817
    • Morgan, P.N.1
  • 16
    • 25444432875 scopus 로고    scopus 로고
    • Thermal modeling of resistive magnets for field-cycled MRI
    • Gilbert KM, Handler WB, Chronik BA. 2005. Thermal modeling of resistive magnets for field-cycled MRI. Magn Reson Eng 26B:56-66.
    • (2005) Magn Reson Eng , vol.26 B , pp. 56-66
    • Gilbert, K.M.1    Handler, W.B.2    Chronik, B.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.