메뉴 건너뛰기




Volumn 77, Issue 3-4, 2007, Pages 361-370

A real time fault analysis tool for monitoring operation of transmission line protective relay

Author keywords

Fault analysis; Fault location; Neural networks; Power system protection; Synchronized sampling

Indexed keywords

COMPUTER SIMULATION; ELECTRIC FAULT CURRENTS; ELECTRIC FAULT LOCATION; ELECTRIC LINES; NEURAL NETWORKS; REAL TIME SYSTEMS;

EID: 33750814700     PISSN: 03787796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.epsr.2006.03.015     Document Type: Article
Times cited : (38)

References (26)
  • 1
    • 0030189082 scopus 로고    scopus 로고
    • Expose hidden failures to prevent cascading outages
    • Phadke A.G., and Thorp J.S. Expose hidden failures to prevent cascading outages. IEEE Comput. Appl. Power 9 3 (1996) 20-23
    • (1996) IEEE Comput. Appl. Power , vol.9 , Issue.3 , pp. 20-23
    • Phadke, A.G.1    Thorp, J.S.2
  • 3
    • 34250824795 scopus 로고    scopus 로고
    • A hybrid expert system for faulted section identification, fault type classification and selection of fault location algorithms
    • Girgis A.A., and Johns M.B. A hybrid expert system for faulted section identification, fault type classification and selection of fault location algorithms. IEEE Trans. Power Delivery 4 2 (1996) 978-985
    • (1996) IEEE Trans. Power Delivery , vol.4 , Issue.2 , pp. 978-985
    • Girgis, A.A.1    Johns, M.B.2
  • 4
    • 0037249753 scopus 로고    scopus 로고
    • A new protection scheme for fault detection, direction discrimination, classification, and location in transmission lines
    • Jiang J., Chen C., and Liu C. A new protection scheme for fault detection, direction discrimination, classification, and location in transmission lines. IEEE Trans. Power Delivery 18 1 (2003) 34-42
    • (2003) IEEE Trans. Power Delivery , vol.18 , Issue.1 , pp. 34-42
    • Jiang, J.1    Chen, C.2    Liu, C.3
  • 5
    • 27144452336 scopus 로고    scopus 로고
    • A complete scheme for fault detection, classification and location in transmission lines using neural networks, Developments in Power System Protection, 2001
    • Oleskovicz M., Coury D.V., and Aggarwal R.K. A complete scheme for fault detection, classification and location in transmission lines using neural networks, Developments in Power System Protection, 2001. Proceedings of the 7th International Conference on (IEE) (2001) 335-338
    • (2001) Proceedings of the 7th International Conference on (IEE) , pp. 335-338
    • Oleskovicz, M.1    Coury, D.V.2    Aggarwal, R.K.3
  • 6
    • 0030086222 scopus 로고    scopus 로고
    • Automated transmission line fault analysis using synchronized sampling at two ends
    • Kezunovic M., and Perunicic B. Automated transmission line fault analysis using synchronized sampling at two ends. IEEE Trans. Power Syst. 11 1 (1996) 441-447
    • (1996) IEEE Trans. Power Syst. , vol.11 , Issue.1 , pp. 441-447
    • Kezunovic, M.1    Perunicic, B.2
  • 7
    • 84954452818 scopus 로고    scopus 로고
    • Z.Q. Bo, F. Jiang, Z. Chen, Transient based protection for power transmission systems, IEEE PES Winter Meeting, (3) 2000, pp. 1832-1837.
  • 8
    • 0018038509 scopus 로고
    • Ultra high speed relay for EHV/UHV transmission lines - development, design and application
    • Chamia M., and Liberman S. Ultra high speed relay for EHV/UHV transmission lines - development, design and application. IEEE Trans. PAS 97 (1978) 2104-2112
    • (1978) IEEE Trans. PAS , vol.97 , pp. 2104-2112
    • Chamia, M.1    Liberman, S.2
  • 9
    • 0023844455 scopus 로고
    • Scheme, based on traveling waves for the protection of major transmission lines
    • Christopoulos C., Thomas D., and Wright A. Scheme, based on traveling waves for the protection of major transmission lines. IEE Proc. Part C 135 (1988) 63-73
    • (1988) IEE Proc. Part C , vol.135 , pp. 63-73
    • Christopoulos, C.1    Thomas, D.2    Wright, A.3
  • 10
    • 0028384045 scopus 로고
    • A novel non-unit protection technique for EHV transmission systems based on fault-generated noise. Part 1. Signal measurement
    • Johns A.T., Aggarwal R.K., and Bo Z.Q. A novel non-unit protection technique for EHV transmission systems based on fault-generated noise. Part 1. Signal measurement. IEE Proc. Gener. Trans. Distrib. 141 2 (1994) 133-140
    • (1994) IEE Proc. Gener. Trans. Distrib. , vol.141 , Issue.2 , pp. 133-140
    • Johns, A.T.1    Aggarwal, R.K.2    Bo, Z.Q.3
  • 11
    • 0028384045 scopus 로고
    • A novel non-unit protection technique for EHV transmission systems based on fault-generated noise. Part 2. Signal processing
    • Aggarwal R.K., Johns A.T., and Bo Z.Q. A novel non-unit protection technique for EHV transmission systems based on fault-generated noise. Part 2. Signal processing. IEE Proc. Gener. Trans. Distrib. 141 2 (1994) 133-140
    • (1994) IEE Proc. Gener. Trans. Distrib. , vol.141 , Issue.2 , pp. 133-140
    • Aggarwal, R.K.1    Johns, A.T.2    Bo, Z.Q.3
  • 12
    • 0034223831 scopus 로고    scopus 로고
    • Positional protection of transmission line using fault generated high frequency transient signals
    • Bo Z.Q., Redfern M.A., and Weller G.C. Positional protection of transmission line using fault generated high frequency transient signals. IEEE Trans. Power Delivery 15 3 (2000) 888-894
    • (2000) IEEE Trans. Power Delivery , vol.15 , Issue.3 , pp. 888-894
    • Bo, Z.Q.1    Redfern, M.A.2    Weller, G.C.3
  • 13
    • 17744393875 scopus 로고    scopus 로고
    • Fuzzy ART neural network algorithm for classifying the power system faults
    • Vasilic S., and Kezunovic M. Fuzzy ART neural network algorithm for classifying the power system faults. IEEE Trans. Power Delivery 20 2 (2005) 1306-1314
    • (2005) IEEE Trans. Power Delivery , vol.20 , Issue.2 , pp. 1306-1314
    • Vasilic, S.1    Kezunovic, M.2
  • 14
    • 0028426833 scopus 로고
    • An accurate fault location algorithm using synchronized sampling
    • Kezunovic M., Perunicic B., and Mrkic J. An accurate fault location algorithm using synchronized sampling. Electric Power Syst. Res. 29 3 (1994) 161-169
    • (1994) Electric Power Syst. Res. , vol.29 , Issue.3 , pp. 161-169
    • Kezunovic, M.1    Perunicic, B.2    Mrkic, J.3
  • 15
    • 84973857317 scopus 로고
    • ART2: self-organization of stable category recognition codes for analog input patterns
    • Carpenter G.A., and Grossberg S. ART2: self-organization of stable category recognition codes for analog input patterns. Appl. Opt. 26 23 (1987) 4919-4930
    • (1987) Appl. Opt. , vol.26 , Issue.23 , pp. 4919-4930
    • Carpenter, G.A.1    Grossberg, S.2
  • 17
    • 33750807990 scopus 로고    scopus 로고
    • Working Group C6 of the System Protection Subcommittee of the IEEE Power System Relaying Committee, Wide area protection and emergency control, Techical Report, 2002 [Online] Available: http://www.pes-psrc.org/.
  • 19
    • 33750835412 scopus 로고    scopus 로고
    • Technical reference manual: Phasor measurement terminal RES 521*1.0, ABB, [Online] Available: http://www.abb.com.
  • 20
    • 33750803530 scopus 로고    scopus 로고
    • TR-2000 multi-function recorder brochure, Ametek power instrument, [Online] Available: http://www.ametekpower.com.
  • 21
    • 33750842723 scopus 로고    scopus 로고
    • CanAm EMTP User Group, Alternative Transient Program (ATP) Rule Book, Portland, 1992.
  • 22
    • 33750796726 scopus 로고    scopus 로고
    • The MathWorks Inc., Using MATLAB, Natick, 2002.
  • 23
    • 33746486060 scopus 로고    scopus 로고
    • Design and implementation of scenarios for evaluating and testing distance relays
    • College Station, TX
    • Ristanovic D., Vasilic S., and Kezunovic M. Design and implementation of scenarios for evaluating and testing distance relays. North American Power Symposium - NAPS. College Station, TX (2001)
    • (2001) North American Power Symposium - NAPS
    • Ristanovic, D.1    Vasilic, S.2    Kezunovic, M.3
  • 25
    • 51549112506 scopus 로고    scopus 로고
    • A study of synchronized sampling based fault location algorithm performance under power swing and out-of-step conditions
    • St. Petersburg, Russia, June
    • Zhang N., and Kezunovic M. A study of synchronized sampling based fault location algorithm performance under power swing and out-of-step conditions. 2005 IEEE St. Petersburg PowerTech'05. St. Petersburg, Russia, June (2005)
    • (2005) 2005 IEEE St. Petersburg PowerTech'05
    • Zhang, N.1    Kezunovic, M.2
  • 26
    • 0005685695 scopus 로고
    • Fundamental basis for distance relaying on 3-phase systems
    • Lewis W.A., and Tippet S. Fundamental basis for distance relaying on 3-phase systems. AIEE Trans. 66 (1947) 694-708
    • (1947) AIEE Trans. , vol.66 , pp. 694-708
    • Lewis, W.A.1    Tippet, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.