메뉴 건너뛰기




Volumn 113, Issue 3, 2006, Pages 345-347

Left main coronary artery 'embolectomy' using a novel, straightforward technique

Author keywords

Aspiration thrombectomy; Coronary artery bypass grafting; Embolism

Indexed keywords

ADULT; ANAMNESIS; ANGIOCARDIOGRAPHY; ARTERY EMBOLISM; ARTICLE; ASPIRATION; CASE REPORT; CLINICAL FEATURE; CORONARY ARTERY BYPASS GRAFT; ELECTROCARDIOGRAM; EMBOLECTOMY; HEART CATHETERIZATION; HEMODYNAMIC MONITORING; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; LEFT CORONARY ARTERY; MALE; PRIORITY JOURNAL; THROMBECTOMY;

EID: 33750737085     PISSN: 01675273     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijcard.2005.11.055     Document Type: Article
Times cited : (2)

References (5)
  • 1
    • 0037029354 scopus 로고    scopus 로고
    • Early and midterm outcome after off-pump and on-pump surgery in beating heart against cardioplegic arrest studies (BHACAS 1 and 2): a pooled analysis of two randomised controlled trials
    • Angelini G.D., Taylor F.C., Reeves B.C., and Ascione R. Early and midterm outcome after off-pump and on-pump surgery in beating heart against cardioplegic arrest studies (BHACAS 1 and 2): a pooled analysis of two randomised controlled trials. Lancet 359 9313 (2002) 1194-1199
    • (2002) Lancet , vol.359 , Issue.9313 , pp. 1194-1199
    • Angelini, G.D.1    Taylor, F.C.2    Reeves, B.C.3    Ascione, R.4
  • 2
    • 0036843293 scopus 로고    scopus 로고
    • Coronary artery saddle embolus and myocardial infarction in a patient with prosthetic mitral valve
    • Aslam M.S., Sanghi V., Hersh S., and Lakier J.B. Coronary artery saddle embolus and myocardial infarction in a patient with prosthetic mitral valve. Catheter Cardiovasc Interv 57 3 (2002) 367-370
    • (2002) Catheter Cardiovasc Interv , vol.57 , Issue.3 , pp. 367-370
    • Aslam, M.S.1    Sanghi, V.2    Hersh, S.3    Lakier, J.B.4
  • 3
    • 12244255057 scopus 로고    scopus 로고
    • Preliminary experiences using X-sizer catheter for mechanical thrombectomy of thrombus-containing lesions during acute coronary syndromes
    • Kornowski R., Ayzenberg O., Halon D.A., Kusniec F., and Assali A. Preliminary experiences using X-sizer catheter for mechanical thrombectomy of thrombus-containing lesions during acute coronary syndromes. Catheter Cardiovasc Interv 58 4 (2003) 443-448
    • (2003) Catheter Cardiovasc Interv , vol.58 , Issue.4 , pp. 443-448
    • Kornowski, R.1    Ayzenberg, O.2    Halon, D.A.3    Kusniec, F.4    Assali, A.5
  • 4
    • 0036844114 scopus 로고    scopus 로고
    • Export aspiration catheter thrombosuction before actual angioplasty in primary coronary intervention for acute myocardial infarction
    • Wang H.J., Kao H.L., Liau C.S., and Lee Y.T. Export aspiration catheter thrombosuction before actual angioplasty in primary coronary intervention for acute myocardial infarction. Catheter Cardiovasc Interv 57 3 (2002) 332-339
    • (2002) Catheter Cardiovasc Interv , vol.57 , Issue.3 , pp. 332-339
    • Wang, H.J.1    Kao, H.L.2    Liau, C.S.3    Lee, Y.T.4
  • 5
    • 0032190007 scopus 로고    scopus 로고
    • Intracoronary aspiration thrombectomy for acute myocardial infarction
    • Murakami T., Mizuno S., Takahashi Y., et al. Intracoronary aspiration thrombectomy for acute myocardial infarction. Am J Cardiol 82 7 (1998) 839-844
    • (1998) Am J Cardiol , vol.82 , Issue.7 , pp. 839-844
    • Murakami, T.1    Mizuno, S.2    Takahashi, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.