메뉴 건너뛰기




Volumn 73, Issue 5, 2006, Pages 350-352

Our experience with an image guided navigation system for accurate alignment in total hip replacement by minimally invasive posterolateral surgery;Zkušenosti s navigací jamky TEP kyčelního kloubu při posterolaterálním miniinvazivním přístupu

Author keywords

Cementless acetabular component; Kinematic navigation system; Minimally invasive technique; Posterolateral approach

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CLINICAL ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; CONTROLLED STUDY; FEMALE; HIP MALFORMATION; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; MALE; MINIMALLY INVASIVE SURGERY; SURGICAL APPROACH; TOTAL HIP PROSTHESIS; HIP ARTHROPLASTY; MIDDLE AGED;

EID: 33750733283     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (22)
  • 1
    • 0022489328 scopus 로고
    • Anteversion of the Acetabular cup: Measurement of Angle after Total Hip Replacement
    • ACKLAND, M. K., BOURNE, W. B., UHTHOFF, H. K.: Anteversion of the Acetabular cup: Measurement of Angle after Total Hip Replacement. J. Bone Jt Surg., 68-B: 409-413, 1986
    • (1986) J. Bone Jt Surg. , vol.68 B , pp. 409-413
    • Ackland, M.K.1    Bourne, W.B.2    Uhthoff, H.K.3
  • 2
    • 0034945667 scopus 로고    scopus 로고
    • The Effects of Implant Position, Design and Wear on the Range of Motion after Total Hip Arthroplasty
    • BADER, R. J., STEINHAUSER, E., WILLMANN, G., GRADINGER, R.: The Effects of Implant Position, Design and Wear on the Range of Motion after Total Hip Arthroplasty. Hip International, 11: 80-90, 2001.
    • (2001) Hip International , vol.11 , pp. 80-90
    • Bader, R.J.1    Steinhauser, E.2    Willmann, G.3    Gradinger, R.4
  • 3
    • 0037822087 scopus 로고    scopus 로고
    • Dislocation After Total Hip Artrhoplasty: Implant Design and Orientation
    • BARRACK, R. L.: Dislocation After Total Hip Artrhoplasty: Implant Design and Orientation. J. Amer. Acad. Orthop. Surg., 11: 89-99, 2003.
    • (2003) J. Amer. Acad. Orthop. Surg. , vol.11 , pp. 89-99
    • Barrack, R.L.1
  • 4
    • 0345060421 scopus 로고    scopus 로고
    • Total Hip Arthroplasty Using the Minimally Invasive Two-incision Approach
    • BERGER, R. A.: Total Hip Arthroplasty Using the Minimally Invasive Two-incision Approach. Clin. Orthop., 417: 232-241, 2003.
    • (2003) Clin. Orthop. , vol.417 , pp. 232-241
    • Berger, R.A.1
  • 5
    • 20844454380 scopus 로고    scopus 로고
    • Reducing the Risk of Dislocation after Total Hip Arthroplasty: Effect of Orientation of the Acetabular Component
    • BEEDERMANN, R., TONIN, A., KRISMER, M., RACHBAUER, F. Reducing the Risk of Dislocation after Total Hip Arthroplasty: Effect of Orientation of the Acetabular Component. J. Bone Jt Surg., 87-B: 762-769, 2005.
    • (2005) J. Bone Jt Surg. , vol.87 B , pp. 762-769
    • Beedermann, R.1    Tonin, A.2    Krismer, M.3    Rachbauer, F.4
  • 6
    • 17644380275 scopus 로고    scopus 로고
    • The European School of Total Hip Arthroplasty and 35 Years of Total Hip Arthroplasty in the Czech Republic
    • ČECH, O., DŽUPA, V.:The European School of Total Hip Arthroplasty and 35 Years of Total Hip Arthroplasty in the Czech Republic. Acta Chir. orthop. Traum.čech., 72: 57-76, 2005.
    • (2005) Acta Chir. Orthop. Traum.čech. , vol.72 , pp. 57-76
    • Čech, O.1    Džupa, V.2
  • 7
    • 3543068018 scopus 로고
    • Aloplastika kyčelního kloubu
    • Praha, Avicenum
    • ČECH, O., PAVLANSKÝ, R..: Aloplastika kyčelního kloubu. Praha, Avicenum 1983.
    • (1983)
    • Čech, O.1    Pavlanský, R.2
  • 8
    • 0032178167 scopus 로고    scopus 로고
    • Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Aligment
    • DiGIOIA, A. M., JARAMAZ, B., BLACKWELL M.: Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Aligment. Clin. Orthop., 355: 8-22, 1998.
    • (1998) Clin. Orthop. , vol.355 , pp. 8-22
    • Digioia, A.M.1    Jaramaz, B.2    Blackwell, M.3
  • 10
    • 0019057926 scopus 로고
    • Dislocation in Total Hip Arthroplasties
    • FACKLER, C. D., POSS, R.: Dislocation in Total Hip Arthroplasties. Clin. Orthop., 151: 169-178, 1980.
    • (1980) Clin. Orthop. , vol.151 , pp. 169-178
    • Fackler, C.D.1    Poss, R.2
  • 11
    • 14844303965 scopus 로고    scopus 로고
    • Component Position Following Total Hip Arthroplasty through a Miniinvasive Posterolateral Approach
    • HART, R., ŠTIPČÁK, V., JANEČEK, M., VIŠŇA, R: Component Position Following Total Hip Arthroplasty through a Miniinvasive Posterolateral Approach. Acta orthop. belg., 71: 60-64, 2005.
    • (2005) Acta Orthop. Belg. , vol.71 , pp. 60-64
    • Hart, R.1    Štipčák, V.2    Janeček, M.3    Višňa, R.4
  • 13
    • 4444305327 scopus 로고    scopus 로고
    • Computer-assisted Cup Placement Techniques in Total Hip Arthroplasty Improve Accuracy of Placement
    • JOLLES, D. M., GENOUD, R, HOFFMEYER, P.:Computer-assisted Cup Placement Techniques in Total Hip Arthroplasty Improve Accuracy of Placement. Clin. Orthop., 426: 174-179, 2004.
    • (2004) Clin. Orthop. , vol.426 , pp. 174-179
    • Jolles, D.M.1    Genoud, R.2    Hoffmeyer, P.3
  • 14
    • 0031855096 scopus 로고    scopus 로고
    • Effect of Acetabular Component Orientation on Reccurent Dislocation, Pelvic Osteolysis, Polyethylen Wear, and Component Migration
    • KENNEDY, J. G., ROGERS, W. B., SOFFE, K. E., et al.: Effect of Acetabular Component Orientation on Reccurent Dislocation, Pelvic Osteolysis, Polyethylen Wear, and Component Migration. J. Arthroplasty, 13: 530-534, 1998.
    • (1998) J. Arthroplasty , vol.13 , pp. 530-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3
  • 15
    • 0038686676 scopus 로고    scopus 로고
    • OrthoPilot Cup Navigation
    • KIEFER, H.: OrthoPilot Cup Navigation. Int. Ortop., 27: S37-42, 2003.
    • (2003) Int. Ortop. , vol.27
    • Kiefer, H.1
  • 17
    • 0025679123 scopus 로고
    • Dislocation after Total Hip Arthroplasty: Causes and Prevention
    • McCOLLUM, D. E., GRAY, W. J.: Dislocation after Total Hip Arthroplasty: Causes and Prevention. Clin. Orthop., 261: 159-170, 1990.
    • (1990) Clin. Orthop. , vol.261 , pp. 159-170
    • Mccollum, D.E.1    Gray, W.J.2
  • 18
  • 19
    • 16844378626 scopus 로고    scopus 로고
    • A Minimal-Incision Technique in Total Hip Arthroplasty Does Not Improve Early Postoperative Outcomes. A Prospective Randomized, Controled Trial
    • OGONDA, L., WILSON, R., ARCHBOLD, P., LAWLOR, M., HUMPHREYS, P., O BRIEN, S., BEVERLAND, D.: A Minimal-Incision Technique in Total Hip Arthroplasty Does Not Improve Early Postoperative Outcomes. A Prospective Randomized, Controled Trial. J. Bone Jt Surg., 87-A: 701-710, 2005.
    • (2005) J. Bone Jt Surg. , vol.87 A , pp. 701-710
    • Ogonda, L.1    Wilson, R.2    Archbold, P.3    Lawlor, M.4    Humphreys, P.5    O Brien, S.6    Beverland, D.7
  • 20
    • 0030836574 scopus 로고    scopus 로고
    • The Influence of Patient-related Factors and the Position of the Acetabular Component on the Rate of Dislocation after Total Hip Replacement
    • PATERNO, S. A., LACHIEWICZ, P. F., KELLEY, S. S.: The Influence of Patient-related Factors and the Position of the Acetabular Component on the Rate of Dislocation after Total Hip Replacement. J. Bone Jt Surg., 79-A: 1202-1210, 1997.
    • (1997) J. Bone Jt Surg. , vol.79 A , pp. 1202-1210
    • Paterno, S.A.1    Lachiewicz, P.F.2    Kelley, S.S.3
  • 22
    • 3042784998 scopus 로고    scopus 로고
    • Comparison of Primary Total Hip Replacements with a Standart Incision or a Mini-Incision
    • WOOLSON, S. T., MOW, CH. S., SYQUIA, J. F., LANNIN, J. V., SCHURMAN, D. J.: Comparison of Primary Total Hip Replacements with a Standart Incision or a Mini-Incision. J. Bone Jt Surg., 86-A: 1353-1358, 2004.
    • (2004) J. Bone Jt Surg. , vol.86 A , pp. 1353-1358
    • Woolson, S.T.1    Mow, C.H.S.2    Syquia, J.F.3    Lannin, J.V.4    Schurman, D.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.