메뉴 건너뛰기




Volumn 6319, Issue , 2006, Pages

Super-characteristic x-ray generator utilizing a pipe and rod target

Author keywords

Cone beam; Demountable x ray tube; Electron impact source; K series characteristic x rays; Line beam; Quasi monochromatic x rays; Sommerfeld's theory

Indexed keywords

ELECTRON BEAMS; POWER SUPPLY CIRCUITS; RADIOGRAPHY; STAINLESS STEEL; X RAY TUBES;

EID: 33750716858     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.679243     Document Type: Conference Paper
Times cited : (2)

References (16)
  • 4
    • 0035767184 scopus 로고    scopus 로고
    • Free-electron laser at the TESLA test facility at DESY: Toward a tunable short-pulsed soft x-ray source
    • C. Gerth, "Free-electron laser at the TESLA test facility at DESY: toward a tunable short-pulsed soft x-ray source," SPIE, 4505, 131-145, 2001.
    • (2001) SPIE , vol.4505 , pp. 131-145
    • Gerth, C.1
  • 7
    • 22944465716 scopus 로고    scopus 로고
    • Clean monochromatic x-ray irradiation from weakly ionized linear copper plasma
    • E. Sato, E. Tanaka, H. Mori, T. Kawai, S. Sato and K. Takayama, "Clean monochromatic x-ray irradiation from weakly ionized linear copper plasma," Opt. Eng., 44, 049002-1-6, 2005.
    • (2005) Opt. Eng. , vol.44
    • Sato, E.1    Tanaka, E.2    Mori, H.3    Kawai, T.4    Sato, S.5    Takayama, K.6
  • 10
    • 12844255717 scopus 로고    scopus 로고
    • Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube
    • E. Sato, E. Tanaka, H. Mori, T. Kawai, T. Ichimaru, S. Sato, K. Takayama and H. Ido, "Compact monochromatic flash x-ray generator utilizing a disk-cathode molybdenum tube," Med. Phys., 32, 49-54, 2005.
    • (2005) Med. Phys. , vol.32 , pp. 49-54
    • Sato, E.1    Tanaka, E.2    Mori, H.3    Kawai, T.4    Ichimaru, T.5    Sato, S.6    Takayama, K.7    Ido, H.8
  • 13
    • 0032381609 scopus 로고    scopus 로고
    • Development of a two-dimensional imaging system for clinical applications of intravenous coronary angiography using intense synchrotron radiation produced by a multipole wiggler
    • K. Hyodo, M. Ando, Y. Oku, S. Yamamoto, T. Takeda, Y. Itai, S. Ohtsuka, Y. Sugishita and J. Tada, "Development of a two-dimensional imaging system for clinical applications of intravenous coronary angiography using intense synchrotron radiation produced by a multipole wiggler," J. Synchrotron Radiat., S, 1123-1126, 1998.
    • (1998) J. Synchrotron Radiat. , vol.5 , pp. 1123-1126
    • Hyodo, K.1    Ando, M.2    Oku, Y.3    Yamamoto, S.4    Takeda, T.5    Itai, Y.6    Ohtsuka, S.7    Sugishita, Y.8    Tada, J.9
  • 14
    • 9244231786 scopus 로고    scopus 로고
    • Demonstration of enhanced K-edge angiography using a cerium target x-ray generator
    • E. Sato, E. Tanaka, H. Mori, T. Kawai, T. Ichimaru, S. Sato, K. Takayama and H. Ido, "Demonstration of enhanced K-edge angiography using a cerium target x-ray generator," Med. Phys, 31, 3017-3021, 2004.
    • (2004) Med. Phys , vol.31 , pp. 3017-3021
    • Sato, E.1    Tanaka, E.2    Mori, H.3    Kawai, T.4    Ichimaru, T.5    Sato, S.6    Takayama, K.7    Ido, H.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.