-
3
-
-
0032295098
-
Test results of the Readout Electronics for Nuclear Applications (RENA) chip developed for position-sensitive solid state detectors
-
S.D. Kravis, D.G. Maeding , T.O. Tüer, G. Visser, S. Yin, "Test results of the Readout Electronics for Nuclear Applications (RENA) chip developed for position-sensitive solid state detectors," SPIE Symp. Proc. 3445, 374 (1998). See: http://www.novarad.com/pages/documents/ RENA__test_results_SPIE_1998.PDF
-
(1998)
SPIE Symp. Proc.
, vol.3445
, pp. 374
-
-
Kravis, S.D.1
Maeding, D.G.2
Tüer, T.O.3
Visser, G.4
Yin, S.5
-
4
-
-
0034594133
-
Front-End Electronics for Spectroscopy Applications (FESA) IC
-
contribution to the Lyon, France, October 15-20
-
M. Clajus, T.O. Türner, G.J. Visser, S. Yin, P.D. Willson, and D.G. Maeding, "Front-End Electronics for Spectroscopy Applications (FESA) IC," contribution to the IEEE Nuclear Science Symposium 2000, Lyon, France, October 15-20, 2000.
-
(2000)
IEEE Nuclear Science Symposium 2000
-
-
Clajus, M.1
Türner, T.O.2
Visser, G.J.3
Yin, S.4
Willson, P.D.5
Maeding, D.G.6
-
5
-
-
23844549905
-
Multi-energy x-ray imaging with linear CZT arrays and integrated electronics
-
Rome
-
V.B. Cajipe, M. Clajus, O. Yossifor, R. Jayaraman, B. Grattan, S. Hayakawa, R.F. Calderwood and T.O. Turner, "Multi-energy x-ray imaging with linear CZT arrays and integrated electronics", IEEE RTSD conference record, Rome, 2004.
-
(2004)
IEEE RTSD Conference Record
-
-
Cajipe, V.B.1
Clajus, M.2
Yossifor, O.3
Jayaraman, R.4
Grattan, B.5
Hayakawa, S.6
Calderwood, R.F.7
Turner, T.O.8
-
6
-
-
0033347287
-
Hybrid direct conversion detectors for digital mammography
-
Shi Yin et al, "Hybrid direct conversion detectors for digital mammography," IEEE Transactions on Nuclear Science, Vol. 46, No. 6 (1999) 2093-2097.
-
(1999)
IEEE Transactions on Nuclear Science
, vol.46
, Issue.6
, pp. 2093-2097
-
-
Yin, S.1
-
7
-
-
23844436344
-
Compact detector modules for high resolution PET imaging with LYSO and avalanche photodiode arrays
-
Rome
-
This paper focuses on readout chips for direct conversion detectors. NOVA also has ICs designed for applications using scintillator crystals and PMTs or APDs. See for example, M. Clajus et al, "Compact detector modules for high resolution PET imaging with LYSO and avalanche photodiode arrays" IEEE MIC conference record, Rome, 2004.
-
(2004)
IEEE MIC Conference Record
-
-
Clajus, M.1
-
8
-
-
33750739092
-
Test results of a CdZnTe pixel detector read out by RENA-2 IC
-
Presented at the Rome, Italy (October 2004) and submitted to IEEE Trans. Nucl. Sci.
-
T.O. Tümer, V.B. Cajipe, M. Clajus, F. Duttweiler, S. Hayakawa, J.L. Matteson, A. Shirley, O. Yossifor. "Test results of a CdZnTe pixel detector read out by RENA-2 IC," Presented at the 4th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors, Rome, Italy (October 2004) and submitted to IEEE Trans. Nucl. Sci.
-
4th International Workshop on Room-temperature Semiconductor X-ray and Gamma-ray Detectors
-
-
Tümer, T.O.1
Cajipe, V.B.2
Clajus, M.3
Duttweiler, F.4
Hayakawa, S.5
Matteson, J.L.6
Shirley, A.7
Yossifor, O.8
-
9
-
-
0034452180
-
Preliminary test results of pixel detectors developed for the All-sky X-ray & Gamma-ray Astronomy Monitor (AXGAM)
-
Dec.
-
T.O. Tümer, et al., "Preliminary test results of pixel detectors developed for the All-sky X-ray & Gamma-ray Astronomy Monitor (AXGAM)," Trans. of Nucl. Science, 47, 1938-1944 (Dec. 2000).
-
(2000)
Trans. of Nucl. Science
, vol.47
, pp. 1938-1944
-
-
Tümer, T.O.1
|