메뉴 건너뛰기




Volumn 75, Issue 12, 2006, Pages 2182-2185

Clinical count rate performance of an LSO PET/CT scanner utilizing a new front-end electronics architecture with sub-nanosecond intrinsic timing resolution

Author keywords

Cancer imaging; Multi modality; PET CT

Indexed keywords

COMPUTERIZED TOMOGRAPHY; ELECTRONIC EQUIPMENT; IMAGING SYSTEMS; PHOSPHORS; SPURIOUS SIGNAL NOISE; TUMORS;

EID: 33750693411     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2006.02.011     Document Type: Article
Times cited : (5)

References (13)
  • 1
    • 0032761238 scopus 로고    scopus 로고
    • Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations
    • Adam L.-E., Karp J.S., and Brix G. Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations. Phys. Med. Biol. 44 (1999) 2879-2895
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2879-2895
    • Adam, L.-E.1    Karp, J.S.2    Brix, G.3
  • 3
    • 4344604152 scopus 로고    scopus 로고
    • PET count rate performance and CT image quality of a 16-slice LSO PET/CT for clinical whole-body imaging
    • Carney J.P.J., Yap J.T., and Townsend D.W. PET count rate performance and CT image quality of a 16-slice LSO PET/CT for clinical whole-body imaging. Radiat. Phys. Chem. 71 (2004) 963-965
    • (2004) Radiat. Phys. Chem. , vol.71 , pp. 963-965
    • Carney, J.P.J.1    Yap, J.T.2    Townsend, D.W.3
  • 4
    • 0034092414 scopus 로고    scopus 로고
    • Scintillation crystals for PET
    • Melcher C.L. Scintillation crystals for PET. J. Nucl. Med. 41 (2000) 1051-1055
    • (2000) J. Nucl. Med. , vol.41 , pp. 1051-1055
    • Melcher, C.L.1
  • 5
    • 0142126690 scopus 로고    scopus 로고
    • Time of flight in PET revisited
    • Moses W.W. Time of flight in PET revisited. IEEE Trans. Nucl. Sci. 50 (2003) 1325-1330
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 1325-1330
    • Moses, W.W.1
  • 7
    • 33750742083 scopus 로고    scopus 로고
    • National Electrical Manufacturers Association, 2001. Performance measurement of positron emission tomographs. NEMA Standards Publication NU 2-2001, Rosslyn, VA.
  • 8
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalent counts
    • Strother S.C., Casey M.E., and Hoffman E.J. Measuring PET scanner sensitivity: relating count rates to image signal-to-noise ratios using noise equivalent counts. IEEE Trans. Nucl. Sci. 37 (1990) 783-788
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 11
    • 8344228611 scopus 로고    scopus 로고
    • Count rate dependence of local signal-to-noise ratio in positron emission tomography
    • Watson C.C. Count rate dependence of local signal-to-noise ratio in positron emission tomography. IEEE Trans. Nucl. Sci. 51 (2004) 2670-2680
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2670-2680
    • Watson, C.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.