-
2
-
-
0035143138
-
Impaction technique and graft treatment in revisions of the femoral component: laboratory studies and clinical validation
-
Hostner J., Hultmark P., Karrholm J., Malchau H., and Tveit M. Impaction technique and graft treatment in revisions of the femoral component: laboratory studies and clinical validation. J Arthroplasty 16 (2001) 76-82
-
(2001)
J Arthroplasty
, vol.16
, pp. 76-82
-
-
Hostner, J.1
Hultmark, P.2
Karrholm, J.3
Malchau, H.4
Tveit, M.5
-
3
-
-
0033622796
-
Mechanical validation of whole bone composite tibia models
-
Cristofolini L., and Viceconti M. Mechanical validation of whole bone composite tibia models. J Biomech 33 (2000) 279-288
-
(2000)
J Biomech
, vol.33
, pp. 279-288
-
-
Cristofolini, L.1
Viceconti, M.2
-
4
-
-
0037820585
-
Experimental investigation of bone remodelling using composite femurs
-
Waide V., Cristofolini L., Stolk J., Verdonschot N., and Toni A. Experimental investigation of bone remodelling using composite femurs. Clin Biomech 18 (2003) 523-536
-
(2003)
Clin Biomech
, vol.18
, pp. 523-536
-
-
Waide, V.1
Cristofolini, L.2
Stolk, J.3
Verdonschot, N.4
Toni, A.5
-
5
-
-
4344618352
-
The use of rapid prototyping in the preoperative planning of distraction osteogenesis of the cranio-maxillofacial skeleton
-
Poukens J., Haex J., and Riediger D. The use of rapid prototyping in the preoperative planning of distraction osteogenesis of the cranio-maxillofacial skeleton. Comput Aided Surg 8 3 (2003) 146-154
-
(2003)
Comput Aided Surg
, vol.8
, Issue.3
, pp. 146-154
-
-
Poukens, J.1
Haex, J.2
Riediger, D.3
-
6
-
-
0036096602
-
Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases
-
Brown G.A., Milner B., and Firoozbakhsh K. Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases. J Orthop Trauma 16 5 (May 2002) 347-352
-
(2002)
J Orthop Trauma
, vol.16
, Issue.5
, pp. 347-352
-
-
Brown, G.A.1
Milner, B.2
Firoozbakhsh, K.3
-
7
-
-
31544443577
-
The use of rapid prototyping to assist medical applications
-
Gibson I., Cheung L.K., Chow S.P., Cheung W.L., Beh S.L., Savalani M., et al. The use of rapid prototyping to assist medical applications. Rapid Prototyping J 12 (2006) 53-58
-
(2006)
Rapid Prototyping J
, vol.12
, pp. 53-58
-
-
Gibson, I.1
Cheung, L.K.2
Chow, S.P.3
Cheung, W.L.4
Beh, S.L.5
Savalani, M.6
-
8
-
-
33750579479
-
-
Greer B, Wang E. Whole_tibia.igs. The ISB Finite Element Repository, Instituti Rizzoli, Bologna, 1999. http://www.cineca.it/hosted/LTM/back2net/ISB_mesh (Accessed in 2003).
-
-
-
-
9
-
-
33750585812
-
-
Shellabear, M. Model manufacturing processes-state of the art in rapid prototyping. Brite/Euram project BE-2051, 1999, RAPTEC task 4.2, report 1.
-
-
-
-
11
-
-
18944374771
-
Mechanical testing of impaction bone grafting in the tibia: initial stability and design of the stem
-
Toms A.D., McClelland D., Chua L., de Waal Malefijt M., Verdonschot N., Jones R.S., et al. Mechanical testing of impaction bone grafting in the tibia: initial stability and design of the stem. J Bone Joint Surg Br 87B (2005) 656-663
-
(2005)
J Bone Joint Surg Br
, vol.87 B
, pp. 656-663
-
-
Toms, A.D.1
McClelland, D.2
Chua, L.3
de Waal Malefijt, M.4
Verdonschot, N.5
Jones, R.S.6
-
12
-
-
0022356106
-
Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth
-
Cheal E.J., Lee C.H., Synder B.D., and Miller J. Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth. J Orthop Res 3 (1985) 424-434
-
(1985)
J Orthop Res
, vol.3
, pp. 424-434
-
-
Cheal, E.J.1
Lee, C.H.2
Synder, B.D.3
Miller, J.4
-
13
-
-
0024549669
-
Load transfer characteristics of a noncemented total knee arthroplasty
-
Whiteside L.A., and Pafford J. Load transfer characteristics of a noncemented total knee arthroplasty. Clin Orthop Relat Res 239 (1989) 168-177
-
(1989)
Clin Orthop Relat Res
, vol.239
, pp. 168-177
-
-
Whiteside, L.A.1
Pafford, J.2
-
14
-
-
0037388823
-
Tibial component fixation with cement: full versus surface-cementation techniques
-
Peters C.L., Craig M.A., Mohr R.A., and Bachus K.N. Tibial component fixation with cement: full versus surface-cementation techniques. Clin Orthop Relat Res 409 (2003) 158-168
-
(2003)
Clin Orthop Relat Res
, vol.409
, pp. 158-168
-
-
Peters, C.L.1
Craig, M.A.2
Mohr, R.A.3
Bachus, K.N.4
-
15
-
-
0030804819
-
Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
-
Lee S.C., Coan B.S., and Bouxsein M.L. Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone. Bone 21 (1997) 119-125
-
(1997)
Bone
, vol.21
, pp. 119-125
-
-
Lee, S.C.1
Coan, B.S.2
Bouxsein, M.L.3
|