메뉴 건너뛰기




Volumn 29, Issue 10 SUPPL., 2006, Pages

Minimally invasive orthopedic surgery: First results in navigated total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOVASCULAR DISEASE; CLAMP; CLINICAL ARTICLE; COMPUTER ASSISTED SURGERY; COMPUTER SYSTEM; DISLOCATION; FEMALE; FRACTURE; HEART DISEASE; HEMATOMA; HUMAN; IMAGE ANALYSIS; MINIMALLY INVASIVE SURGERY; NERVE LESION; OPERATION DURATION; ORTHOPEDIC SURGERY; PATIENT POSITIONING; PERIOPERATIVE PERIOD; SKIN FISSURE; SURGICAL APPROACH; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS;

EID: 33750575306     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (20)
  • 1
    • 0020356121 scopus 로고
    • Dislocations after total hip arthroplasty
    • Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982; 64:1295-1306.
    • (1982) J Bone Joint Surg Am. , vol.64 , pp. 1295-1306
    • Woo, R.Y.1    Morrey, B.F.2
  • 2
    • 0027264738 scopus 로고
    • Heterotopic bone after hip arthroplasty. Defining the patient at risk
    • Ahrengart L, Lindgren U. Heterotopic bone after hip arthroplasty. Defining the patient at risk. Clin Orthop Relat Res. 1993; 293:153-159.
    • (1993) Clin Orthop Relat Res. , vol.293 , pp. 153-159
    • Ahrengart, L.1    Lindgren, U.2
  • 3
    • 0020619480 scopus 로고
    • Factor associated with heterotopic bone formation in cemented total hip prostheses
    • Hierton C, Blomgren G, Lindgren U. Factor associated with heterotopic bone formation in cemented total hip prostheses. Acta Orthop Scand. 1983; 54:698-702.
    • (1983) Acta Orthop Scand. , vol.54 , pp. 698-702
    • Hierton, C.1    Blomgren, G.2    Lindgren, U.3
  • 4
    • 0025274452 scopus 로고
    • Integrity of the gluteus medius after the transgluteal approach in total hip arthroplasty
    • Svensson O, Skold S, Blomgren G. Integrity of the gluteus medius after the transgluteal approach in total hip arthroplasty. J Anthroplasty. 1990; 5:57-60.
    • (1990) J Anthroplasty , vol.5 , pp. 57-60
    • Svensson, O.1    Skold, S.2    Blomgren, G.3
  • 5
    • 0029803617 scopus 로고    scopus 로고
    • Damage to the superior gluteal nerve after the Hardinge approach to the hip
    • Ramesh M, O'Byrne JM, McCarthy N, et al. Damage to the superior gluteal nerve after the Hardinge approach to the hip. J Bone Joint Surg Br. 1996; 78:903-906.
    • (1996) J Bone Joint Surg Br. , vol.78 , pp. 903-906
    • Ramesh, M.1    O'Byrne, J.M.2    McCarthy, N.3
  • 8
    • 0242413082 scopus 로고    scopus 로고
    • Total hip arthroplasty through a minimally invasive anterior surgical approach
    • Kennon RE, Keggi JM, Wetmore RS, et al. Total hip arthroplasty through a minimally invasive anterior surgical approach. J Bone Joint Surg Am. 2003; 85(suppl A)4:39-48.
    • (2003) J Bone Joint Surg Am. , vol.85 , Issue.4 SUPPL. A , pp. 39-48
    • Kennon, R.E.1    Keggi, J.M.2    Wetmore, R.S.3
  • 9
    • 3342974412 scopus 로고    scopus 로고
    • Mini-incision for total hip arthroplasty: A prospective, controlled investigation with 5-year follow-up evaluation
    • Wright JM, Crockett HC, Delgado S, et al. Mini-incision for total hip arthroplasty: a prospective, controlled investigation with 5-year follow-up evaluation. J Arthroplasty. 2004; 19:538-545.
    • (2004) J Arthroplasty , vol.19 , pp. 538-545
    • Wright, J.M.1    Crockett, H.C.2    Delgado, S.3
  • 10
    • 0345060421 scopus 로고    scopus 로고
    • Total hip arthroplasty using the minimally invasive two-incision approach
    • Berger RA. Total hip arthroplasty using the minimally invasive two-incision approach. Clin Orthop Relat Res. 2003; 417:232-241.
    • (2003) Clin Orthop Relat Res. , vol.417 , pp. 232-241
    • Berger, R.A.1
  • 11
    • 0242407408 scopus 로고    scopus 로고
    • Minimally invasive total hip arthroplasty. Development, early results, and a critical analysis
    • Berry DJ, Berger RA, Callaghan JJ, et al. Minimally invasive total hip arthroplasty. Development, early results, and a critical analysis. J Bone Joint Surg Am. 2003; 85:2235-2246.
    • (2003) J Bone Joint Surg Am. , vol.85 , pp. 2235-2246
    • Berry, D.J.1    Berger, R.A.2    Callaghan, J.J.3
  • 12
    • 33750586532 scopus 로고    scopus 로고
    • Minimal invasive implantation of total hip arthroplasty using a modified antero-lateral approach. Technique and intraoperative results
    • Paper presented at: October 19-22, Berlin, Germany
    • Walde TA, Kuttler W, Blattgerste D, Walde HJ. Minimal invasive implantation of total hip arthroplasty using a modified antero-lateral approach. Technique and intraoperative results. Paper presented at: Annual meeting of Joint German Congress of Orthopedics and Trauma Surgery; October 19-22, 2005; Berlin, Germany.
    • (2005) Annual Meeting of Joint German Congress of Orthopedics and Trauma Surgery
    • Walde, T.A.1    Kuttler, W.2    Blattgerste, D.3    Walde, H.J.4
  • 13
    • 0038686676 scopus 로고    scopus 로고
    • OrthoPilot cup navigation - How to optimize cup positioning?
    • Kiefer H. OrthoPilot cup navigation - how to optimize cup positioning? Int Orthop. 2003; 27: S37-S42.
    • (2003) Int Orthop. , vol.27
    • Kiefer, H.1
  • 14
    • 0036220612 scopus 로고    scopus 로고
    • Comparison of a mechanical acetabular alignment guide with computer placement of the socket
    • Digioia AM III Jaramaz B, Plakseychuk AY, et al. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty. 2002; 17:359-364.
    • (2002) J Arthroplasty , vol.17 , pp. 359-364
    • Digioia III, A.M.1    Jaramaz, B.2    Plakseychuk, A.Y.3
  • 15
    • 2442431775 scopus 로고    scopus 로고
    • CT-based and fluoroscopy-based navigation for cup implantation in total hip arthroplasty (THA)
    • Hube R, Birke A, Hein W, Klima S. CT-based and fluoroscopy-based navigation for cup implantation in total hip arthroplasty (THA). Surg Technol Int. 2003; 11:275-280.
    • (2003) Surg Technol Int. , vol.11 , pp. 275-280
    • Hube, R.1    Birke, A.2    Hein, W.3    Klima, S.4
  • 16
    • 26444484481 scopus 로고    scopus 로고
    • Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation
    • Wixson RL, MacDonald MA. Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty. 2005; 20:51-56.
    • (2005) J Arthroplasty , vol.20 , pp. 51-56
    • Wixson, R.L.1    MacDonald, M.A.2
  • 17
    • 33644902628 scopus 로고    scopus 로고
    • Navigation-assisted minimally invasive two-incision total hip arthoplasty
    • Weil Y, Mattan Y, Kandel L, Eisenberg O, Liebergall M. Navigation-assisted minimally invasive two-incision total hip arthoplasty. Orthopedics. 2006; 29:200-206.
    • (2006) Orthopedics , vol.29 , pp. 200-206
    • Weil, Y.1    Mattan, Y.2    Kandel, L.3    Eisenberg, O.4    Liebergall, M.5
  • 19
    • 27744556693 scopus 로고    scopus 로고
    • OrthoPilot total hip arthroplasty workflow and surgery
    • Kiefer H, Othman A. OrthoPilot total hip arthroplasty workflow and surgery. Orthopedics. 2005; 28(10 suppl):S1221-S1226.
    • (2005) Orthopedics , vol.28 , Issue.10 SUPPL.
    • Kiefer, H.1    Othman, A.2
  • 20
    • 27744556692 scopus 로고    scopus 로고
    • Results with navigated bicontact total hip arthroplasty
    • Lazovic D, Kaib N. Results with navigated bicontact total hip arthroplasty. Orthopedics. 2005; 28: S1227-S1233.
    • (2005) Orthopedics , vol.28
    • Lazovic, D.1    Kaib, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.