메뉴 건너뛰기




Volumn 47, Issue 6, 2006, Pages 553-562

Image fusion of computed tomographic and magnetic resonance images for the development of a three-dimensional musculoskeletal model of the equine forelimb

Author keywords

Computed tomography; Equine musculoskeletal model; Image fusion; Magnetic resonance (MR); Multimodality registration

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; BIOLOGICAL MODEL; COMPUTER ASSISTED TOMOGRAPHY; EVALUATION; FEMALE; FORELIMB; HISTOLOGY; HORSE; MUSCULOSKELETAL SYSTEM; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; RADIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 33750557006     PISSN: 10588183     EISSN: 17408261     Source Type: Journal    
DOI: 10.1111/j.1740-8261.2006.00185.x     Document Type: Article
Times cited : (19)

References (34)
  • 1
    • 0025470348 scopus 로고
    • An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
    • Delp SL, Loan JP, Hoy GM, et al. An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans Biomed Eng 1990;37:757-767.
    • (1990) IEEE Trans Biomed Eng , vol.37 , pp. 757-767
    • Delp, S.L.1    Loan, J.P.2    Hoy, G.M.3
  • 2
    • 0034086751 scopus 로고    scopus 로고
    • Accuracy of muscle moment arms estimated from MRI-based musculoskeletal models of the lower extremity
    • Arnold A, Salinas S, Asakawa D, Delp S. Accuracy of muscle moment arms estimated from MRI-based musculoskeletal models of the lower extremity. Comput Aided Surg 2000;5:108-119.
    • (2000) Comput Aided Surg , vol.5 , pp. 108-119
    • Arnold, A.1    Salinas, S.2    Asakawa, D.3    Delp, S.4
  • 4
    • 0035259913 scopus 로고    scopus 로고
    • A musculoskeletal model of the upper limb based on the visible human male dataset
    • Garner BA, Pandy MG. A musculoskeletal model of the upper limb based on the visible human male dataset. Comput Meth Biomech Biomed Eng 2001;4:93-126.
    • (2001) Comput Meth Biomech Biomed Eng , vol.4 , pp. 93-126
    • Garner, B.A.1    Pandy, M.G.2
  • 5
    • 0002851901 scopus 로고    scopus 로고
    • A computational framework for simulating and analyzing human and animal movement
    • Delp SL. A computational framework for simulating and analyzing human and animal movement. IEEE Comput Sci Eng 2000;2:46-55.
    • (2000) IEEE Comput Sci Eng , vol.2 , pp. 46-55
    • Delp, S.L.1
  • 6
    • 0025425217 scopus 로고
    • Variation in conformation of Swedish Warmblood horses and conformational characteristics of elite sport horses
    • Holmstrom M, Magnusson LE, Philipsson J. Variation in conformation of Swedish Warmblood horses and conformational characteristics of elite sport horses. Equine Vet J 1990;22:186-193.
    • (1990) Equine Vet J , vol.22 , pp. 186-193
    • Holmstrom, M.1    Magnusson, L.E.2    Philipsson, J.3
  • 7
    • 3042572066 scopus 로고    scopus 로고
    • Conformation and movement
    • Stashak TS (ed): Philadelphia, PA: Lippincott Williams & Wilkins
    • Stashak TS, Hill C. Conformation and movement. In: Stashak TS (ed): Adams' lameness in horses. Philadelphia, PA: Lippincott Williams & Wilkins, 2002;73-111.
    • (2002) Adams' Lameness in Horses , pp. 73-111
    • Stashak, T.S.1    Hill, C.2
  • 10
    • 0001965026 scopus 로고    scopus 로고
    • The ANALYZE software system for visualization and analysis in surgery simulation
    • Taylor RH, Lavallee S, Burdea GC, Mosges R (eds): Cambridge, MA: The MIT Press
    • Robb RA, Hanson DP. The ANALYZE software system for visualization and analysis in surgery simulation. In: Taylor RH, Lavallee S, Burdea GC, Mosges R (eds): Computer-integrated surgery technology and clinical applications. Cambridge, MA: The MIT Press, 1996;175-189.
    • (1996) Computer-integrated Surgery Technology and Clinical Applications , pp. 175-189
    • Robb, R.A.1    Hanson, D.P.2
  • 12
    • 3042581207 scopus 로고    scopus 로고
    • Determination of muscle architecture and fiber characteristics of the superficial and deep digital flexor muscles in the forelimbs of adult horses
    • Zarucco L, Taylor KT, Stover SM. Determination of muscle architecture and fiber characteristics of the superficial and deep digital flexor muscles in the forelimbs of adult horses. Am J Vet Res 2004;65:819-828.
    • (2004) Am J Vet Res , vol.65 , pp. 819-828
    • Zarucco, L.1    Taylor, K.T.2    Stover, S.M.3
  • 14
    • 0034140301 scopus 로고    scopus 로고
    • Interpolation artefacts in mutual information-based image registration
    • Pluim J, Maintz A, Viergever M. Interpolation artefacts in mutual information-based image registration. Comput Vision Image Understanding 2000;77:211-232.
    • (2000) Comput Vision Image Understanding , vol.77 , pp. 211-232
    • Pluim, J.1    Maintz, A.2    Viergever, M.3
  • 15
    • 0002701132 scopus 로고
    • A review of medical image registration
    • Maciunas RJ (ed): Parkridge, IL: American Association of Neurological Surgeons
    • Maurer CR, Fitzpatrick JM. A review of medical image registration. In: Maciunas RJ (ed): Interactive image-guided neurosurgery. Parkridge, IL: American Association of Neurological Surgeons, 1993;17-44.
    • (1993) Interactive Image-guided Neurosurgery , pp. 17-44
    • Maurer, C.R.1    Fitzpatrick, J.M.2
  • 16
    • 0028213621 scopus 로고
    • Image fusion for stereotactic radiotherapy and radiosurgery treatment planning
    • Kooy HM, van Herk M, Barnes PD, et al. Image fusion for stereotactic radiotherapy and radiosurgery treatment planning. Int J Radiat Oncol Biol Phys 1994;28:1229-1234.
    • (1994) Int J Radiat Oncol Biol Phys , vol.28 , pp. 1229-1234
    • Kooy, H.M.1    Van Herk, M.2    Barnes, P.D.3
  • 17
    • 0030868628 scopus 로고    scopus 로고
    • Computed tomography-magnetic resonance image fusion: A clinical evaluation of an innovative approach for improved tumor localization in primary central nervous system lesions
    • Lattanzi J, Fein D, McNeeley S, et al. Computed tomography-magnetic resonance image fusion: a clinical evaluation of an innovative approach for improved tumor localization in primary central nervous system lesions. Radiat Oncol Invest 1997;5:195-205.
    • (1997) Radiat Oncol Invest , vol.5 , pp. 195-205
    • Lattanzi, J.1    Fein, D.2    McNeeley, S.3
  • 18
    • 0036980953 scopus 로고    scopus 로고
    • Automatic 3D registration for interventional MRI-guided treatment of prostate cancer
    • Fei B, Duerk J, Wilson D. Automatic 3D registration for interventional MRI-guided treatment of prostate cancer. Comput Aided Surg 2002;7:257-267.
    • (2002) Comput Aided Surg , vol.7 , pp. 257-267
    • Fei, B.1    Duerk, J.2    Wilson, D.3
  • 19
    • 0036134928 scopus 로고    scopus 로고
    • Digital image fusion of early and delayed CT scans: How to achieve optimal opacification of vessels and squamous cell carcinomas of the head and neck
    • Groell R, Wiltgen M, Wolf G, Habermann W. Digital image fusion of early and delayed CT scans: how to achieve optimal opacification of vessels and squamous cell carcinomas of the head and neck. Am J Roentgenol 2002;178:211.
    • (2002) Am J Roentgenol , vol.178 , pp. 211
    • Groell, R.1    Wiltgen, M.2    Wolf, G.3    Habermann, W.4
  • 22
    • 0026370529 scopus 로고
    • A computer-assisted system for 3-D frameless localization in stereotaxic MRI
    • Clarysse P, Gibon D, Rousseau J, et al. A computer-assisted system for 3-D frameless localization in stereotaxic MRI. IEEE Trans Med Imag 1991;10:523-525.
    • (1991) IEEE Trans Med Imag , vol.10 , pp. 523-525
    • Clarysse, P.1    Gibon, D.2    Rousseau, J.3
  • 23
    • 0030175675 scopus 로고    scopus 로고
    • An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head
    • Wang MY, Maurer CR, Fitzpatrick JM, Maciunas RJ. An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head. IEEE Trans Biomed Eng 1996;43:627-637.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 627-637
    • Wang, M.Y.1    Maurer, C.R.2    Fitzpatrick, J.M.3    Maciunas, R.J.4
  • 24
    • 0032129160 scopus 로고    scopus 로고
    • Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain
    • Fitzpatrick JM, Hill DLG, Shyr Y, et al. Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain. IEEE Trans Med lmag 1998;17:571-585.
    • (1998) IEEE Trans Med Lmag , vol.17 , pp. 571-585
    • Fitzpatrick, J.M.1    Hill, D.L.G.2    Shyr, Y.3
  • 25
    • 0035133708 scopus 로고    scopus 로고
    • A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data
    • Fischer KT, Manson TT, Pfaeffle HJ, Tomaino MM, Woo SLY. A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data. J Biomech 2001;34:377-383.
    • (2001) J Biomech , vol.34 , pp. 377-383
    • Fischer, K.T.1    Manson, T.T.2    Pfaeffle, H.J.3    Tomaino, M.M.4    Woo, S.L.Y.5
  • 26
    • 18644376601 scopus 로고    scopus 로고
    • Musculoskeletal modeling and dynamic simulation of the thoroughbred equine forelimb during stance phase of the gallop
    • Swanstrom MD, Zarucco L, Hubbard M, Stover SM, Hawkins DA. Musculoskeletal modeling and dynamic simulation of the thoroughbred equine forelimb during stance phase of the gallop. J Biomech Eng 2005;127:318-328.
    • (2005) J Biomech Eng , vol.127 , pp. 318-328
    • Swanstrom, M.D.1    Zarucco, L.2    Hubbard, M.3    Stover, S.M.4    Hawkins, D.A.5
  • 27
    • 0242285655 scopus 로고    scopus 로고
    • An in vivo equine forelimb model for short-term recording of peak isometric force in the superficial and deep digital flexor muscles
    • Zarucco L, Swanstrom MD, Driessen B, et al. An in vivo equine forelimb model for short-term recording of peak isometric force in the superficial and deep digital flexor muscles. Vet Surg 2003;32:439-450 .
    • (2003) Vet Surg , vol.32 , pp. 439-450
    • Zarucco, L.1    Swanstrom, M.D.2    Driessen, B.3
  • 28
    • 12344264878 scopus 로고    scopus 로고
    • Passive and active mechanical properties of the superficial and deep digital flexor muscles in the forelimbs of anesthetized thoroughbred horses
    • Swanstrom MD, Zarucco L, Stover SM, et al. Passive and active mechanical properties of the superficial and deep digital flexor muscles in the forelimbs of anesthetized thoroughbred horses. J Biomech 2005;38:579-586.
    • (2005) J Biomech , vol.38 , pp. 579-586
    • Swanstrom, M.D.1    Zarucco, L.2    Stover, S.M.3
  • 29
    • 1542300820 scopus 로고    scopus 로고
    • Determination of passive mechanical properties of the superficial and deep digital flexor muscle-ligament-tendon complexes in the forelimbs of horses
    • Swanstrom MD, Stover SM, Hubbard M, Hawkins D. Determination of passive mechanical properties of the superficial and deep digital flexor muscle-ligament-tendon complexes in the forelimbs of horses. Am J Vet Res 2004;65:188-197.
    • (2004) Am J Vet Res , vol.65 , pp. 188-197
    • Swanstrom, M.D.1    Stover, S.M.2    Hubbard, M.3    Hawkins, D.4
  • 30
    • 14844283155 scopus 로고    scopus 로고
    • Lameness associated with foot pain: Results of magnetic resonance imaging in 199 horses (January 2001-December 2003) and response to treatment
    • Dyson S, Murray R, Schramme MC. Lameness associated with foot pain: results of magnetic resonance imaging in 199 horses (January 2001-December 2003) and response to treatment. Equine Vet J 2005;37:113-121.
    • (2005) Equine Vet J , vol.37 , pp. 113-121
    • Dyson, S.1    Murray, R.2    Schramme, M.C.3
  • 31
    • 5644257281 scopus 로고    scopus 로고
    • Use of computed tomography angiography to evaluate the vascular anatomy of the distal portion of the forelimb of horses
    • Collins JN, Galuppo LD, Thomas HL, Wisner ER, Hornof WJ. Use of computed tomography angiography to evaluate the vascular anatomy of the distal portion of the forelimb of horses. J Am Vet Med Assoc 2004;65:1409-1420.
    • (2004) J Am Vet Med Assoc , vol.65 , pp. 1409-1420
    • Collins, J.N.1    Galuppo, L.D.2    Thomas, H.L.3    Wisner, E.R.4    Hornof, W.J.5
  • 32
    • 0942298530 scopus 로고    scopus 로고
    • Use of magnetic resonance imaging for identifying subchondral bone damage in horses: 11 cases
    • Zubrod CJ, Schneider RK, Tucker RL, et al. Use of magnetic resonance imaging for identifying subchondral bone damage in horses: 11 cases. J Am Vet Med Assoc 2004;224:411-418.
    • (2004) J Am Vet Med Assoc , vol.224 , pp. 411-418
    • Zubrod, C.J.1    Schneider, R.K.2    Tucker, R.L.3
  • 33
    • 0032062764 scopus 로고    scopus 로고
    • The diagnosis of lameness associated with distal limb pathology in the horse; a comparison of radiography, computed tomography and magnetic resonance imaging
    • Whitton RC, Buckley C, Donovan T, Wales AD, Dennis R. The diagnosis of lameness associated with distal limb pathology in the horse; a comparison of radiography, computed tomography and magnetic resonance imaging. Vet J 1998;155:223-229.
    • (1998) Vet J , vol.155 , pp. 223-229
    • Whitton, R.C.1    Buckley, C.2    Donovan, T.3    Wales, A.D.4    Dennis, R.5
  • 34
    • 23044500916 scopus 로고    scopus 로고
    • Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: An in vitro study
    • Andritzky J, Rossol M, Lischer C, Auer JA. Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: an in vitro study. Vet Surg 2005;34:120-127.
    • (2005) Vet Surg , vol.34 , pp. 120-127
    • Andritzky, J.1    Rossol, M.2    Lischer, C.3    Auer, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.