메뉴 건너뛰기




Volumn 6297, Issue , 2006, Pages

Variable and fixed-point blackbody sources developed at VNIIOFI for precision measurements in radiometry and thermometry within 100K...3500K temperature range

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; EUTECTICS; INFRARED DEVICES; PRECISION ENGINEERING; TEMPERATURE MEASUREMENT; THERMAL EFFECTS;

EID: 33750553600     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.684053     Document Type: Conference Paper
Times cited : (3)

References (20)
  • 1
    • 0025212765 scopus 로고
    • National primary radiometric standards of the USSR
    • Sapritski V.I. National Primary Radiometric Standards of the USSR, Metrologia, 1990, v.27, No. 1, p. 53-60.
    • (1990) Metrologia , vol.27 , Issue.1 , pp. 53-60
    • Sapritski, V.I.1
  • 2
    • 0030146430 scopus 로고
    • Black-body radiometry
    • Sapritsky V.I. Black-body radiometry. Metrologia, 32, pp. 411-417, 1995/1996.
    • (1995) Metrologia , vol.32 , pp. 411-417
    • Sapritsky, V.I.1
  • 3
    • 85113654670 scopus 로고    scopus 로고
    • Spectral radiance comparison of two blackbodies with temperatures determined using absolute detectors and ITS-90 techniques
    • edited by Dean C. Ripple, AIP Conference Proceedings 684, Chicago, IL, USA
    • Yoon H.W., Gibson C.E., Gardner J.L., Spectral radiance comparison of two blackbodies with temperatures determined using absolute detectors and ITS-90 techniques, Proceedings of the 8th International Temperature Symposium, edited by Dean C. Ripple, AIP Conference Proceedings 684, vol.7, Chicago, IL, USA, 2003, pp. 601-606
    • (2003) Proceedings of the 8th International Temperature Symposium , vol.7 , pp. 601-606
    • Yoon, H.W.1    Gibson, C.E.2    Gardner, J.L.3
  • 5
    • 0034474404 scopus 로고    scopus 로고
    • Preliminary results of the investigation of a 3500 K black body
    • E.R. Woolliams, N.J. Harrison, N.P. Fox. Preliminary results of the investigation of a 3500 K black body. Metrologia, 2000, v. 37, p. 501-504.
    • (2000) Metrologia , vol.37 , pp. 501-504
    • Woolliams, E.R.1    Harrison, N.J.2    Fox, N.P.3
  • 6
    • 0034473339 scopus 로고    scopus 로고
    • New spectral radiance scale from 220 to 2500 nm
    • R. Friedrich and J. Fischer, New spectral radiance scale from 220 to 2500 nm. Metrologia, 2000, v. 37, p. 539-542.
    • (2000) Metrologia , vol.37 , pp. 539-542
    • Friedrich, R.1    Fischer, J.2
  • 8
    • 33750568751 scopus 로고    scopus 로고
    • High-temperature reference black bodies for precision radiometry of optical radiation
    • in Russian
    • B.B.Khlevnoy High-temperature reference black bodies for precision radiometry of optical radiation. Metrologia, 2001, No 6, p.3-16, (in Russian).
    • (2001) Metrologia , Issue.6 , pp. 3-16
    • Khlevnoy, B.B.1
  • 10
    • 0038643586 scopus 로고    scopus 로고
    • Dissemination of ultra-precise measurements in radiometry and remote sensing within 100...3500K temperature range on the base of blackbody sources developed in VNIIOFI
    • (10-11 July 2002, Seattle, WA, USA), edited by M.Strojnik, B.Andresen, SPIE, Bellingham, WA
    • Sapritsky V.I., Ogarev S.A., Khlevnoy B.B., Samoylov M.L., Khromchenko V.B., Morozova S.P. Dissemination of Ultra-Precise Measurements in Radiometry and Remote Sensing within 100...3500K Temperature Range on the Base of Blackbody Sources developed in VNIIOFI, Proc. of SPIE Vol. 4818 "IR Spaceborne remote sensing X" (10-11 July 2002, Seattle, WA, USA), edited by M.Strojnik, B.Andresen, (SPIE, Bellingham, WA, 2002), pp.127-136.
    • (2002) Proc. of SPIE Vol. 4818 "IR Spaceborne Remote Sensing X" , pp. 127-136
    • Sapritsky, V.I.1    Ogarev, S.A.2    Khlevnoy, B.B.3    Samoylov, M.L.4    Khromchenko, V.B.5    Morozova, S.P.6
  • 14
    • 0026846739 scopus 로고
    • Calculation of the effective emissivities of specular-diffuse cavities by the Monte Carlo method
    • Sapritsky V.I. and Prokhorov A.V. Calculation of the Effective Emissivities of Specular-Diffuse Cavities by the Monte Carlo Method,1992 Metrologia, v.29, pp.9-14
    • (1992) Metrologia , vol.29 , pp. 9-14
    • Sapritsky, V.I.1    Prokhorov, A.V.2
  • 19
    • 0037228593 scopus 로고    scopus 로고
    • Development of metal-carbon high-temperature fixed-point blackbodies for precision photometry and radiometry
    • V.I. Sapristky, S.A. Ogarev, B.B. Khlevnoy, M.L. Samoylov, V.B. Khromchenko Development of metal-carbon high-temperature fixed-point blackbodies for precision photometry and radiometry. Metrologia, 40 (2003), No.1, S128-S131.
    • (2003) Metrologia , vol.40 , Issue.1
    • Sapristky, V.I.1    Ogarev, S.A.2    Khlevnoy, B.B.3    Samoylov, M.L.4    Khromchenko, V.B.5
  • 20
    • 59349115794 scopus 로고    scopus 로고
    • Precision extended-area low temperature blackbody BB100-VI for IR calibrations in medium background environment
    • paper 083, Davos, Switzerland
    • S. Ogarev, M. Samoylov, V. Sapritsky, A. Panfilov, S. Koichi, T. Kawashima Precision Extended-Area Low Temperature Blackbody BB100-VI for IR Calibrations in Medium Background Environment, NEWRAD'2005, paper 083, Davos, Switzerland, 2005
    • (2005) NEWRAD'2005
    • Ogarev, S.1    Samoylov, M.2    Sapritsky, V.3    Panfilov, A.4    Koichi, S.5    Kawashima, T.6