Volumn 20, Issue 5, 2006, Pages 305-309

Effect of peripheral vasoconstriction on pulse oximetry

Author keywords

Human; Oxygen saturation; Pulse oximetry; Temperature; Vasoconstriction; Vasodilation

Indexed keywords

ANESTHETICS; HEMODYNAMICS; HEMOGLOBIN OXYGEN SATURATION; LIGHT TRANSMISSION; TEMPERATURE;

EID: 33750542967     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-006-9022-3     Document Type: Article
Times cited : (44)

References (8)
  • 1
    • 0023000494 scopus 로고
    • Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography
    • Kim JM, Arakawa K, Benson KT, Fox DK. Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography. Anesth Analg 1986; 65: 1333-1339.
    • (1986) Anesth Analg , vol.65 , pp. 1333-1339
    • Kim, J.M.1    Arakawa, K.2    Benson, K.T.3    Fox, D.K.4
  • 2
    • 0024414277 scopus 로고
    • The penumbra effect: Vasomotion-dependent pulse oximeter artifact due to probe malposition
    • Kelleher JF, Ruff RH. The penumbra effect: Vasomotion-dependent pulse oximeter artifact due to probe malposition. Anesthesiology 1989; 71: 787-791.
    • (1989) Anesthesiology , vol.71 , pp. 787-791
    • Kelleher, J.F.1    Ruff, R.H.2
  • 3
    • 0026520756 scopus 로고
    • Thermoregulatory vasoconstriction during isoflurane anesthesia minimally decreases cutaneous heat loss
    • Sessler Dl, McGuire J, Hynson J, Moayeri A, Heier T. Thermoregulatory vasoconstriction during isoflurane anesthesia minimally decreases cutaneous heat loss. Anesthesiology 1992; 76: 670-675.
    • (1992) Anesthesiology , vol.76 , pp. 670-675
    • Sessler, D.L.1    McGuire, J.2    Hynson, J.3    Moayeri, A.4    Heier, T.5
  • 5
    • 0030951656 scopus 로고    scopus 로고
    • Effect of local limb temperature on pulse oximetry and the plethysmographic pulse wave
    • Schramm WM, Bartunek A, Gilly H. Effect of local limb temperature on pulse oximetry and the plethysmographic pulse wave. Int J Clin Monit Comput 1997; 14: 17-22.
    • (1997) Int J Clin Monit Comput , vol.14 , pp. 17-22
    • Schramm, W.M.1    Bartunek, A.2    Gilly, H.3
  • 6
    • 0026245735 scopus 로고
    • Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry
    • Sami HM, Kleinman BS, Lonchyna VA. Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry. J Clin Monit 1991; 7: 309-312.
    • (1991) J Clin Monit , vol.7 , pp. 309-312
    • Sami, H.M.1    Kleinman, B.S.2    Lonchyna, V.A.3