메뉴 건너뛰기




Volumn 33, Issue 11, 2006, Pages 4379-4383

Accurate calibration of a stereo-vision system in image-guided radiotherapy

Author keywords

Calibration; Patient positioning; Radiotherapy; Stereo vision

Indexed keywords

CALIBRATION; LEAST SQUARES APPROXIMATIONS; RADIOTHERAPY; STEREO VISION;

EID: 33750534995     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2362873     Document Type: Article
Times cited : (9)

References (11)
  • 1
    • 0032965071 scopus 로고    scopus 로고
    • Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy
    • R. Rogus, R. Stern, and H. Pedotti, " Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy., " Med. Phys. 26, 712-728 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 712-728
    • Rogus, R.1    Stern, R.2    Pedotti, H.3
  • 2
    • 31844450232 scopus 로고    scopus 로고
    • Real-time three-dimensional video image-guided radiation therapy: Emerging technology
    • edited by A. J.Mundt, and J. C.Roeske (B. C. Decker, Inc
    • S. Li and J. Geng, " Real-time three-dimensional video image-guided radiation therapy: Emerging technology., " in Intensity Modulated Radiation Therapy: A Clinical Perspective, edited by, A. J. Mundt,, and, J. C. Roeske, (B. C. Decker, Inc, 2005).
    • (2005) Intensity Modulated Radiation Therapy: A Clinical Perspective
    • Li, S.1    Geng, J.2
  • 3
    • 12844249330 scopus 로고    scopus 로고
    • Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer
    • D. Djajaputra and S. Li, " Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer., " Med. Phys. 32, 65-75 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 65-75
    • Djajaputra, D.1    Li, S.2
  • 4
    • 25644432884 scopus 로고    scopus 로고
    • A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
    • C. Bert, K. G. Metheany, K. Doppka, and G. T. Y. Chen, " A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup., " Med. Phys. 32, 2753-2762 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 2753-2762
    • Bert, C.1    Metheany, K.G.2    Doppka, K.3    Chen, G.T.Y.4
  • 5
    • 31844437062 scopus 로고    scopus 로고
    • Real-time surface-image-guided head refixation in fractionated stereotactic radiotherapy
    • S. Li, D. Liu, G. Yin, and J. Geng, " Real-time surface-image-guided head refixation in fractionated stereotactic radiotherapy., " Med. Phys. 33, 492-503 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 492-503
    • Li, S.1    Liu, D.2    Yin, G.3    Geng, J.4
  • 7
    • 33645512814 scopus 로고    scopus 로고
    • Video-surface-guided respiratory motion correction for 3D static CT images
    • D. Liu, J. Geng, G. Yin, and S. Li, " Video-surface-guided respiratory motion correction for 3D static CT images., " Med. Phys. 32, 1927 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 1927
    • Liu, D.1    Geng, J.2    Yin, G.3    Li, S.4
  • 8
    • 0007798308 scopus 로고    scopus 로고
    • Rainbow 3-D camera: New concept of high-speed three dimensional vision system
    • Z. J. Geng, " Rainbow 3-D camera: New concept of high-speed three dimensional vision system., " Opt. Eng. (Bellingham) 35, 376-383 (1996).
    • (1996) Opt. Eng. (Bellingham) , vol.35 , pp. 376-383
    • Geng, Z.J.1
  • 11
    • 0026137964 scopus 로고
    • Least-squares estimation of transformation parameters between two point patterns
    • S. Umeyama, " Least-squares estimation of transformation parameters between two point patterns., " IEEE Trans. Pattern Anal. Mach. Intell. 13 (4), 376-380 (1991).
    • (1991) IEEE Trans. Pattern Anal. Mach. Intell. , vol.13 , Issue.4 , pp. 376-380
    • Umeyama, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.