1
-
-
0035409221
-
Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks
-
Jang K.S., Youn S.J., and Kim Y.S. Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks. J Prosthet Dent 86 (2001) 93-98
-
(2001)
J Prosthet Dent
, vol.86
, pp. 93-98
-
-
Jang, K.S.1
Youn, S.J.2
Kim, Y.S.3
-
2
-
-
0027661397
-
A simple method for inspection of porosity in titanium castings
-
Wang R.R., and Boyle A.M. A simple method for inspection of porosity in titanium castings. J Prosthet Dent 70 (1993) 275-276
-
(1993)
J Prosthet Dent
, vol.70
, pp. 275-276
-
-
Wang, R.R.1
Boyle, A.M.2
-
3
-
-
0029382149
-
Casting of Ti-6Al-4V alloy compared with pure Ti in an Ar-arc casting machine
-
Syverud M., Okabe T., and Hero H. Casting of Ti-6Al-4V alloy compared with pure Ti in an Ar-arc casting machine. Eur J Oral Sci 103 (1995) 327-330
-
(1995)
Eur J Oral Sci
, vol.103
, pp. 327-330
-
-
Syverud, M.1
Okabe, T.2
Hero, H.3
-
5
-
-
0033985882
-
The machinability of cast titanium and Ti-6Al-4V
-
Ohkubo C., Watanabe I., Ford J.P., Nakajima H., Hosoi T., and Okabe T. The machinability of cast titanium and Ti-6Al-4V. Biomaterials 21 (2000) 421-428
-
(2000)
Biomaterials
, vol.21
, pp. 421-428
-
-
Ohkubo, C.1
Watanabe, I.2
Ford, J.P.3
Nakajima, H.4
Hosoi, T.5
Okabe, T.6
-
6
-
-
0024345249
-
Studies of Ti alloys for dental casting
-
Taira M., Moser J.B., and Greener E.H. Studies of Ti alloys for dental casting. Dent Mater 5 (1989) 45-50
-
(1989)
Dent Mater
, vol.5
, pp. 45-50
-
-
Taira, M.1
Moser, J.B.2
Greener, E.H.3
-
7
-
-
0034329977
-
Effect of pressure of helium, argon, krypton, and xenon on the porosity, microstructure, and mechanical properties of commercially pure titanium castings
-
Zinelis S. Effect of pressure of helium, argon, krypton, and xenon on the porosity, microstructure, and mechanical properties of commercially pure titanium castings. J Prosthet Dent 84 (2000) 575-582
-
(2000)
J Prosthet Dent
, vol.84
, pp. 575-582
-
-
Zinelis, S.1
-
8
-
-
0020339536
-
Effect of magnesia investments in the dental casting of pure titanium or titanium alloys
-
Ida K., Togaya T., Tsutsumi S., and Takeuchi M. Effect of magnesia investments in the dental casting of pure titanium or titanium alloys. Dent Mater J 1 (1982) 8-21
-
(1982)
Dent Mater J
, vol.1
, pp. 8-21
-
-
Ida, K.1
Togaya, T.2
Tsutsumi, S.3
Takeuchi, M.4
-
9
-
-
0032654546
-
A metallurgical study of the contamination zone at the surface of dental Ti castings, due to the phosphate-bonded investment material: the protection efficacy of a ceramic coating
-
Papadopoulos T., Zinelis S., and Vardavoulias M. A metallurgical study of the contamination zone at the surface of dental Ti castings, due to the phosphate-bonded investment material: the protection efficacy of a ceramic coating. J Mater Sci 34 (1999) 3639-3646
-
(1999)
J Mater Sci
, vol.34
, pp. 3639-3646
-
-
Papadopoulos, T.1
Zinelis, S.2
Vardavoulias, M.3
-
10
-
-
0031617238
-
Interfacial reactions of cast titanium with mold materials
-
Wang R.R., Welsch G.E., and Castro-Cedeno M. Interfacial reactions of cast titanium with mold materials. Int J Prosthodont 11 (1998) 33-43
-
(1998)
Int J Prosthodont
, vol.11
, pp. 33-43
-
-
Wang, R.R.1
Welsch, G.E.2
Castro-Cedeno, M.3
-
12
-
-
0027874365
-
Effect of casting methods on castability of pure titanium
-
Takahashi J., Zhang J.Z., and Okazaki M. Effect of casting methods on castability of pure titanium. Dent Mater J 12 (1993) 245-252
-
(1993)
Dent Mater J
, vol.12
, pp. 245-252
-
-
Takahashi, J.1
Zhang, J.Z.2
Okazaki, M.3
-
13
-
-
0030202385
-
Surface reaction between titanium castings and investments
-
Oda Y., Kudoh Y., Kawada E., Yoshinari M., and Hasegawa K. Surface reaction between titanium castings and investments. Bull Tokyo Dent Coll 37 (1996) 129-136
-
(1996)
Bull Tokyo Dent Coll
, vol.37
, pp. 129-136
-
-
Oda, Y.1
Kudoh, Y.2
Kawada, E.3
Yoshinari, M.4
Hasegawa, K.5
-
14
-
-
0024869554
-
Layered structure of cast titanium surface
-
Miyakawa O., Watanabe K., Okawa S., Nakano S., Kobayachi M., and Shiokawa N. Layered structure of cast titanium surface. Dent Mater J 8 (1989) 175-185
-
(1989)
Dent Mater J
, vol.8
, pp. 175-185
-
-
Miyakawa, O.1
Watanabe, K.2
Okawa, S.3
Nakano, S.4
Kobayachi, M.5
Shiokawa, N.6
-
15
-
-
0024762179
-
Dental casting of titanium and Ni-Ti alloys by a new casting machine
-
Hamanaka H., Doi H., Yoneyama T., and Okuno O. Dental casting of titanium and Ni-Ti alloys by a new casting machine. J Dent Res 68 (1989) 1529-1533
-
(1989)
J Dent Res
, vol.68
, pp. 1529-1533
-
-
Hamanaka, H.1
Doi, H.2
Yoneyama, T.3
Okuno, O.4
-
16
-
-
0027862659
-
Castability and surface hardness of titanium cast obtained from experimental phosphate-bonded investment molds
-
Takahashi J., Zhang J.Z., and Okazaki M. Castability and surface hardness of titanium cast obtained from experimental phosphate-bonded investment molds. Dent Mater J 12 (1993) 238-244
-
(1993)
Dent Mater J
, vol.12
, pp. 238-244
-
-
Takahashi, J.1
Zhang, J.Z.2
Okazaki, M.3
-
17
-
-
0036832414
-
Titanium casting into phosphate bonded investment with zirconite
-
Luo X.P., Guo T.W., Ou Y.G., and Liu Q. Titanium casting into phosphate bonded investment with zirconite. Dent Mater 18 (2002) 512-515
-
(2002)
Dent Mater
, vol.18
, pp. 512-515
-
-
Luo, X.P.1
Guo, T.W.2
Ou, Y.G.3
Liu, Q.4
-
18
-
-
0027142077
-
Mold filling and porosity in castings of titanium
-
Hero H., Syverud M., and Waarli M. Mold filling and porosity in castings of titanium. Dent Mater 9 (1993) 15-18
-
(1993)
Dent Mater
, vol.9
, pp. 15-18
-
-
Hero, H.1
Syverud, M.2
Waarli, M.3
-
19
-
-
0031255468
-
The effect of sprue design on the roughness and porosity of titanium castings
-
Chan D., Guillory V., Blackman R., and Chung K. The effect of sprue design on the roughness and porosity of titanium castings. J Prosthet Dent 78 (1997) 400-404
-
(1997)
J Prosthet Dent
, vol.78
, pp. 400-404
-
-
Chan, D.1
Guillory, V.2
Blackman, R.3
Chung, K.4
-
20
-
-
0028711948
-
The effect of investment type on the fit of cast titanium crowns
-
Mori T., Jean-Lous M., Yabugami M., and Togaya T. The effect of investment type on the fit of cast titanium crowns. Aust Dent J 39 (1994) 348-352
-
(1994)
Aust Dent J
, vol.39
, pp. 348-352
-
-
Mori, T.1
Jean-Lous, M.2
Yabugami, M.3
Togaya, T.4
-
21
-
-
84989591899
-
Effect of vaccum and supertemperature on mold filling during casting
-
Hero H., and Waarli M. Effect of vaccum and supertemperature on mold filling during casting. Scand J Dent J 99 (1991) 55-59
-
(1991)
Scand J Dent J
, vol.99
, pp. 55-59
-
-
Hero, H.1
Waarli, M.2
-
22
-
-
0020163840
-
A study of the effect of an increased mold temperature on the casting ability of some nonprecious alloys for porcelain veneers
-
Thomson D.V. A study of the effect of an increased mold temperature on the casting ability of some nonprecious alloys for porcelain veneers. J Prosthet Dent 48 (1982) 52-58
-
(1982)
J Prosthet Dent
, vol.48
, pp. 52-58
-
-
Thomson, D.V.1
-
23
-
-
0023512809
-
Casting of dental alloys: mold and alloy temperature effects
-
Hirano S., Tesk J.A., Hinman R.W., Argentar H., and Gregory T.M. Casting of dental alloys: mold and alloy temperature effects. Dent Mater 3 (1987) 307-314
-
(1987)
Dent Mater
, vol.3
, pp. 307-314
-
-
Hirano, S.1
Tesk, J.A.2
Hinman, R.W.3
Argentar, H.4
Gregory, T.M.5
-
25
-
-
16144367589
-
Mold filling of Ti casting using investments with different gas permeability
-
Syverud M., and Hero H. Mold filling of Ti casting using investments with different gas permeability. Dent Mater 11 (1995) 14-18
-
(1995)
Dent Mater
, vol.11
, pp. 14-18
-
-
Syverud, M.1
Hero, H.2
-
26
-
-
0037405702
-
Casting behavior of titanium alloys in a centrifugal casting machine
-
Watanabe K., Miyakawa O., Takada Y., Okuno O., and Okabe T. Casting behavior of titanium alloys in a centrifugal casting machine. Biomaterials 24 (2003) 1737-1743
-
(2003)
Biomaterials
, vol.24
, pp. 1737-1743
-
-
Watanabe, K.1
Miyakawa, O.2
Takada, Y.3
Okuno, O.4
Okabe, T.5
-
27
-
-
0026311511
-
Molten titanium flow in a mesh cavity by the flow visualization technique
-
Watanabe K., Okawa S., Miyakawa O., Nakano S., Shiokawa N., and Kobayashi M. Molten titanium flow in a mesh cavity by the flow visualization technique. Dent Mater J 10 (1991) 128-137
-
(1991)
Dent Mater J
, vol.10
, pp. 128-137
-
-
Watanabe, K.1
Okawa, S.2
Miyakawa, O.3
Nakano, S.4
Shiokawa, N.5
Kobayashi, M.6
-
28
-
-
0034282189
-
Effect of casting method on castability of titanium and dental alloys
-
Watanabe I., Moldu M., Watanabe K., and Okabe T. Effect of casting method on castability of titanium and dental alloys. J Mater Sci Mater Med 11 (2000) 547-553
-
(2000)
J Mater Sci Mater Med
, vol.11
, pp. 547-553
-
-
Watanabe, I.1
Moldu, M.2
Watanabe, K.3
Okabe, T.4
-
29
-
-
0017521529
-
The effect of variations in mould temperature, metal temperature and mould size on the development of internal porosity in cast structures
-
Lewis A.J. The effect of variations in mould temperature, metal temperature and mould size on the development of internal porosity in cast structures. Aust Dent J 22 (1977) 243-246
-
(1977)
Aust Dent J
, vol.22
, pp. 243-246
-
-
Lewis, A.J.1
-
30
-
-
4644297571
-
Pure titanium casting into zirconia-modified magnesia-based investment molds
-
Hung C.C., Hou G.L., Tsai C.C., and Huang C.C. Pure titanium casting into zirconia-modified magnesia-based investment molds. Dent Mater 20 (2004) 846-851
-
(2004)
Dent Mater
, vol.20
, pp. 846-851
-
-
Hung, C.C.1
Hou, G.L.2
Tsai, C.C.3
Huang, C.C.4
|