메뉴 건너뛰기




Volumn 79, Issue 2, 2006, Pages 263-267

Digital photogrammetry for quantitative wear analysis of retrieved TKA components

Author keywords

Arthroplasty; Knee prosthesis; Polyethylene (UHMWPE); Wear; Wear debris

Indexed keywords

ALGORITHMS; BIOMECHANICS; COMPUTER SOFTWARE; JOINTS (ANATOMY); PHOTOGRAMMETRY; PROSTHETICS; UNCERTAIN SYSTEMS;

EID: 33750487508     PISSN: 00219304     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.30537     Document Type: Article
Times cited : (19)

References (13)
  • 2
    • 13844280464 scopus 로고    scopus 로고
    • Failure risk assessment of TKA designs incorporating highly crosslinked UHMWPE
    • Sydney, Australia. Victoria, Australia: Australian Society for Biomaterials
    • Kurtz, SM, Bergstrom JS, Harrigan T, Rimnac CM. Failure risk assessment of TKA designs incorporating highly crosslinked UHMWPE. Transactions of the 7th World Biomaterials Conference, Sydney, Australia. Victoria, Australia: Australian Society for Biomaterials; 2004.
    • (2004) Transactions of the 7th World Biomaterials Conference
    • Kurtz, S.M.1    Bergstrom, J.S.2    Harrigan, T.3    Rimnac, C.M.4
  • 4
    • 0038743250 scopus 로고    scopus 로고
    • Polyethylene damage on the nonarticular surface of modular total knee prostheses
    • Cuckler JM, Lemons J, Tamarapalli JR, Beck P. Polyethylene damage on the nonarticular surface of modular total knee prostheses. Clin Orthop 2003;410:248-253.
    • (2003) Clin Orthop , vol.410 , pp. 248-253
    • Cuckler, J.M.1    Lemons, J.2    Tamarapalli, J.R.3    Beck, P.4
  • 5
    • 0017755054 scopus 로고
    • A scanning electron microscopic study of wear in the plastic components of prosthetic knee and hip joints
    • Cullen JC, Tietjens BR, Poon J, Gavin JB. A scanning electron microscopic study of wear in the plastic components of prosthetic knee and hip joints. Aust N Z J Surg 1977;47:189-192.
    • (1977) Aust N Z J Surg , vol.47 , pp. 189-192
    • Cullen, J.C.1    Tietjens, B.R.2    Poon, J.3    Gavin, J.B.4
  • 6
    • 10444233545 scopus 로고    scopus 로고
    • Analysis of wear asymmetry in a series of 94 retrieved polyethylene tibial bearings
    • Currier JH, Bill MA, Mayor MB. Analysis of wear asymmetry in a series of 94 retrieved polyethylene tibial bearings. J Biomech 2005;38:367-375.
    • (2005) J Biomech , vol.38 , pp. 367-375
    • Currier, J.H.1    Bill, M.A.2    Mayor, M.B.3
  • 7
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
    • Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses. J Biomed Mater Res 1983;17:829-842.
    • (1983) J Biomed Mater Res , vol.17 , pp. 829-842
    • Hood, R.W.1    Wright, T.M.2    Burstein, A.H.3
  • 8
    • 0035100880 scopus 로고    scopus 로고
    • Loosening and osteolysis with the press-fit condylar posterior-cruciate- substituting total knee replacement
    • Mikulak SA, Mahoney OM, dela Rosa MA, Schmalzried TP. Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement. J Bone Joint Surg Am 2001;83-A:398-403.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 398-403
    • Mikulak, S.A.1    Mahoney, O.M.2    Dela Rosa, M.A.3    Schmalzried, T.P.4
  • 12
    • 33750481054 scopus 로고    scopus 로고
    • http://www.univie.ac.at/Luftbildarchiv/wgv/intro.htm
  • 13
    • 0035103906 scopus 로고    scopus 로고
    • Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris
    • Puloski, SK, McCalden, RW, MacDonald, SJ, Rorabeck, CH, Bourne, RB. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am 2001;83-A:390-397.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 390-397
    • Puloski, S.K.1    McCalden, R.W.2    MacDonald, S.J.3    Rorabeck, C.H.4    Bourne, R.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.