메뉴 건너뛰기




Volumn 52, Issue 9-10, 2006, Pages 457-462

Preanalytic indicators of laboratory performances and quality improvement of laboratory testing

Author keywords

Indicators; Laboratory medicine; Preanalytic variability; Quality

Indexed keywords

CLINICAL LABORATORY; EVIDENCE BASED PRACTICE; HEALTH CARE FINANCING; HEALTH CARE POLICY; HUMAN; LABORATORY TEST; LETTER; MATERIALS HANDLING; MONITORING; OUTCOME ASSESSMENT; PATIENT IDENTIFICATION; PERFORMANCE; QUALITY CONTROL; RELIABILITY; SAMPLING; STANDARDIZATION;

EID: 33750465173     PISSN: 14336510     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Letter
Times cited : (25)

References (39)
  • 1
    • 0029134781 scopus 로고
    • Value added laboratory medicine in an era of managed care
    • McDonald JM, Smith JA. Value added laboratory medicine in an era of managed care. Clin Chem 1995;41:1256-62.
    • (1995) Clin Chem , vol.41 , pp. 1256-1262
    • McDonald, J.M.1    Smith, J.A.2
  • 2
    • 10044229035 scopus 로고    scopus 로고
    • Title 42 CFR Parts 493 to end
    • Code of Federal Regulations. Washington, DC: US Government Printing Office
    • Code of Federal Regulations. Title 42 CFR Parts 493 to end. Washington, DC: US Government Printing Office; 1998.
    • (1998)
  • 4
    • 33744822185 scopus 로고    scopus 로고
    • ISO 15189:2003 - Quality management, evaluation and continual improvement
    • Burnett D. ISO 15189:2003 - Quality management, evaluation and continual improvement. Clin Chem Lab Med 2006;44:733-9
    • (2006) Clin Chem Lab Med , vol.44 , pp. 733-739
    • Burnett, D.1
  • 5
    • 10044282992 scopus 로고    scopus 로고
    • Errors in pathology and laboratory medicine: Consequences and prevention
    • Hollensead SC, Lockwood WB, Elin RJ. Errors in pathology and laboratory medicine: consequences and prevention. J Surg Oncol 2004;88:161-81.
    • (2004) J Surg Oncol , vol.88 , pp. 161-181
    • Hollensead, S.C.1    Lockwood, W.B.2    Elin, R.J.3
  • 6
    • 76549221753 scopus 로고
    • The use of control charts in the clinical laboratory
    • Levey S, Jennings ER. The use of control charts in the clinical laboratory. Am J Clin Pathol 1950;20:l059-66.
    • (1950) Am J Clin Pathol , vol.20
    • Levey, S.1    Jennings, E.R.2
  • 7
    • 0038798574 scopus 로고    scopus 로고
    • Appropriateness in programs for continuous quality improvement in clinical laboratories
    • Plebani M. Appropriateness in programs for continuous quality improvement in clinical laboratories. Clin Chim Acta 2003;333: 131-9.
    • (2003) Clin Chim Acta , vol.333 , pp. 131-139
    • Plebani, M.1
  • 8
    • 28844482257 scopus 로고    scopus 로고
    • The preanalytical phase - Can the requirements of the DIN-EN-ISO 15189 be met practically for all laboratories? A view of the "German situation"
    • Wood WG. The preanalytical phase - can the requirements of the DIN-EN-ISO 15189 be met practically for all laboratories? A view of the "German situation". Clin Lab 2005;51:665-71.
    • (2005) Clin Lab , vol.51 , pp. 665-671
    • Wood, W.G.1
  • 9
    • 0038798572 scopus 로고    scopus 로고
    • Error budget calculations in laboratory medicine: Linking the concepts of biological variation and allowable medical errors
    • Stroobants AK, Goldschmidt HM, Plebani M. Error budget calculations in laboratory medicine: linking the concepts of biological variation and allowable medical errors. Clin Chim Acta 2003;333:169-76.
    • (2003) Clin Chim Acta , vol.333 , pp. 169-176
    • Stroobants, A.K.1    Goldschmidt, H.M.2    Plebani, M.3
  • 10
    • 3042740322 scopus 로고    scopus 로고
    • Types and frequency of preanalytical mistakes in the first Thai ISO 9002: 1994 certified clinical laboratory, a 6 - Month monitoring
    • Wiwanitkit V. Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 - month monitoring. BMC Clin Pathol 2001;1:5.
    • (2001) BMC Clin Pathol , vol.1 , pp. 5
    • Wiwanitkit, V.1
  • 12
    • 8844235059 scopus 로고    scopus 로고
    • Identification errors in pathology and laboratory medicine
    • Valenstein PN, Sirota RL. Identification errors in pathology and laboratory medicine. Clin Lab Med 2004,24:979-96.
    • (2004) Clin Lab Med , vol.24 , pp. 979-996
    • Valenstein, P.N.1    Sirota, R.L.2
  • 13
    • 10044255447 scopus 로고    scopus 로고
    • Medical errors: Impact on clinical laboratories and other critical areas
    • Kalra J. Medical errors: impact on clinical laboratories and other critical areas. Clin Biochem 2004;37:1052-62.
    • (2004) Clin Biochem , vol.37 , pp. 1052-1062
    • Kalra, J.1
  • 14
    • 8844271060 scopus 로고    scopus 로고
    • Detecting and preventing the occurrence of errors in the practices of laboratory medicine and anatomic pathology: 15 years' experience with the College of American Pathologists' Q-PROBES and Q-TRACKS programs
    • Novis DA. Detecting and preventing the occurrence of errors in the practices of laboratory medicine and anatomic pathology: 15 years' experience with the College of American Pathologists' Q-PROBES and Q-TRACKS programs. Clin Lab Med 2004;24: 965-67.
    • (2004) Clin Lab Med , vol.24 , pp. 965-967
    • Novis, D.A.1
  • 15
    • 26044440188 scopus 로고    scopus 로고
    • Errors in laboratory medicine: Practical lessons to improve patient safety
    • Howanitz PJ. Errors in laboratory medicine: practical lessons to improve patient safety. Arch Pathol Lab Med 2005;129:1252-61.
    • (2005) Arch Pathol Lab Med , vol.129 , pp. 1252-1261
    • Howanitz, P.J.1
  • 16
    • 26844432302 scopus 로고    scopus 로고
    • Identification of preanalytical mistakes in the stat section of the clinical laboratory
    • Romero A, Munoz M, Ramos JR, Campos A, Ramirez G. Identification of preanalytical mistakes in the stat section of the clinical laboratory. Clin Chem Lab Med 2005;43:974-5.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 974-975
    • Romero, A.1    Munoz, M.2    Ramos, J.R.3    Campos, A.4    Ramirez, G.5
  • 17
    • 33645757592 scopus 로고    scopus 로고
    • Preanalytical variability: The dark side of the moon in laboratory testing
    • Lippi G, Guidi GC, Mattiuzzi C, Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 2006;44:358-65.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 358-365
    • Lippi, G.1    Guidi, G.C.2    Mattiuzzi, C.3    Plebani, M.4
  • 18
    • 33745453893 scopus 로고    scopus 로고
    • Preanalytic errors tracking in a laboratory medicine department. Results of a one-year experience
    • Lippi G, Bassi A, Brocco G, Montagnana M, Salvagno GL, Guidi GC. Preanalytic errors tracking in a laboratory medicine department. Results of a one-year experience. Clin Chem 2006; 52:1442-3.
    • (2006) Clin Chem , vol.52 , pp. 1442-1443
    • Lippi, G.1    Bassi, A.2    Brocco, G.3    Montagnana, M.4    Salvagno, G.L.5    Guidi, G.C.6
  • 19
    • 10644278795 scopus 로고    scopus 로고
    • Patient safety and the preanalytic phase of testing
    • Garon JE. Patient safety and the preanalytic phase of testing. Clin Leadersh Manag Rev 2004;18:322-7.
    • (2004) Clin Leadersh Manag Rev , vol.18 , pp. 322-327
    • Garon, J.E.1
  • 20
    • 4844220810 scopus 로고    scopus 로고
    • An improved failure mode effects analysis for hospitals
    • Krouwer JS. An improved failure mode effects analysis for hospitals. Arch Pathol Lab Med 2004;128:663-7.
    • (2004) Arch Pathol Lab Med , vol.128 , pp. 663-667
    • Krouwer, J.S.1
  • 21
    • 0036827342 scopus 로고    scopus 로고
    • Using a learning curve approach to reduce laboratory error
    • Krouwer JS. Using a learning curve approach to reduce laboratory error. Accred Qual Assur 2002;7:461-7.
    • (2002) Accred Qual Assur , vol.7 , pp. 461-467
    • Krouwer, J.S.1
  • 22
    • 0003666239 scopus 로고
    • Application of risk analysis to food standard issues
    • HACCP. Geneva: World Health Organization; WHO/FNU/FOS/95.3
    • HACCP. Application of risk analysis to food standard issues. Geneva: World Health Organization; 1995. WHO/FNU/FOS/95.3.
    • (1995)
  • 23
  • 24
    • 3242755976 scopus 로고    scopus 로고
    • Quality indicators and specifications for the extra-analytical phases in clinical laboratory management
    • Ricos C, Garcia-Victoria M, de la Fuente B. Quality indicators and specifications for the extra-analytical phases in clinical laboratory management. Clin Chem Lab Med 2004;42:578-82.
    • (2004) Clin Chem Lab Med , vol.42 , pp. 578-582
    • Ricos, C.1    Garcia-Victoria, M.2    de la Fuente, B.3
  • 25
    • 33646564378 scopus 로고    scopus 로고
    • Beyond analytical quality control
    • Hagemann P. Beyond analytical quality control. J Lab Med 2006;30:51-7.
    • (2006) J Lab Med , vol.30 , pp. 51-57
    • Hagemann, P.1
  • 26
    • 33745008882 scopus 로고    scopus 로고
    • Experience of implementing a quality management system in an Ontario hospital laboratory
    • Ho DK. Experience of implementing a quality management system in an Ontario hospital laboratory. Clin Leadersh Manag Rev 2005;19:E3.
    • (2005) Clin Leadersh Manag Rev , vol.19
    • Ho, D.K.1
  • 27
    • 30644478102 scopus 로고    scopus 로고
    • Improving preanalytic processes using the principles of lean production (Toyota Production System)
    • Persoon TJ, Zaleski S, Frerichs J. Improving preanalytic processes using the principles of lean production (Toyota Production System). Am J Clin Pathol 2006;125:16-25.
    • (2006) Am J Clin Pathol , vol.125 , pp. 16-25
    • Persoon, T.J.1    Zaleski, S.2    Frerichs, J.3
  • 29
    • 9144219910 scopus 로고    scopus 로고
    • The laboratory is a key partner in assuring patient safety
    • Stankovic AK. The laboratory is a key partner in assuring patient safety. Clin Lab Med 2004;24:1023-35.
    • (2004) Clin Lab Med , vol.24 , pp. 1023-1035
    • Stankovic, A.K.1
  • 30
    • 23244457645 scopus 로고    scopus 로고
    • Six Sigma project reduces analytical errors in an automated lab
    • Riebling N, Tria L. Six Sigma project reduces analytical errors in an automated lab. MLO Med Lab Obs 2005;37:22-3.
    • (2005) MLO Med Lab Obs , vol.37 , pp. 22-23
    • Riebling, N.1    Tria, L.2
  • 31
    • 0041311220 scopus 로고    scopus 로고
    • Six Sigma: Not for the faint of heart
    • Benedetto AR. Six Sigma: not for the faint of heart. Radiol Manage 2003;25:40-53.
    • (2003) Radiol Manage , vol.25 , pp. 40-53
    • Benedetto, A.R.1
  • 32
    • 10844254632 scopus 로고    scopus 로고
    • Lean Management and Six-Sigma yield big gains in hospital's immediate response laboratory. Quality improvement techniques save more than $400,000
    • Sunyog M. Lean Management and Six-Sigma yield big gains in hospital's immediate response laboratory. Quality improvement techniques save more than $400,000. Clin Leadersh Manag Rev 2004;18:255-8.
    • (2004) Clin Leadersh Manag Rev , vol.18 , pp. 255-258
    • Sunyog, M.1
  • 33
    • 3242784954 scopus 로고    scopus 로고
    • Towards quality specifications in extra-analytical phases of laboratory activity
    • Plebani M. Towards quality specifications in extra-analytical phases of laboratory activity. Clin Chem Lab Med 2004;42:576-7.
    • (2004) Clin Chem Lab Med , vol.42 , pp. 576-577
    • Plebani, M.1
  • 34
    • 0029393769 scopus 로고
    • The commercialization of lab services ... or, make no mistake about it, lab testing is big business
    • Statland BE. The commercialization of lab services ... or, make no mistake about it, lab testing is big business. MLO Med Lab Obs 1995;27:32-7.
    • (1995) MLO Med Lab Obs , vol.27 , pp. 32-37
    • Statland, B.E.1
  • 35
    • 0033658248 scopus 로고    scopus 로고
    • Usefulness of EC4 essential criteria for quality systems of medical laboratories as guideline to the ISO 15189 and ISO 17025 documents
    • European Community Confederation of Clinical Chemistry (EC4) Working Group on Harmonisation of Quality Systems and Accreditation
    • Jansen RT, Kenny D, Blaton V, Burnett D, Huisman W, Plebani M, Queralto SM, Zerah S, van Lieshout J. Usefulness of EC4 essential criteria for quality systems of medical laboratories as guideline to the ISO 15189 and ISO 17025 documents. European Community Confederation of Clinical Chemistry (EC4) Working Group on Harmonisation of Quality Systems and Accreditation. Clin Chem Lab Med 2000;38:1057-64.
    • (2000) Clin Chem Lab Med , vol.38 , pp. 1057-1064
    • Jansen, R.T.1    Kenny, D.2    Blaton, V.3    Burnett, D.4    Huisman, W.5    Plebani, M.6    Queralto, S.M.7    Zerah, S.8    van Lieshout, J.9
  • 36
    • 0003684842 scopus 로고    scopus 로고
    • Samples: From the patient to the laboratory: The impact of preanalytical variables on the quality of laboratory results
    • 3rd Revised Edition Whiley-VCH Verlag GmbH & Co Editor. Weinheim; 2003
    • Guder WG, Narayanan S, Wisser H, Zawta B. Samples: From the patient to the laboratory: the impact of preanalytical variables on the quality of laboratory results, 3rd Revised Edition 2003. Whiley-VCH Verlag GmbH & Co Editor. Weinheim; 2003.
    • (2003)
    • Guder, W.G.1    Narayanan, S.2    Wisser, H.3    Zawta, B.4
  • 37
    • 33745875319 scopus 로고    scopus 로고
    • Phlebotomy issues and quality improvement in results of laboratory testing
    • Lippi G, Salvagno GL, Montagnana M, Franchini M, Guidi GC. Phlebotomy issues and quality improvement in results of laboratory testing. Clin Lab 2006;52:217-30.
    • (2006) Clin Lab , vol.52 , pp. 217-230
    • Lippi, G.1    Salvagno, G.L.2    Montagnana, M.3    Franchini, M.4    Guidi, G.C.5
  • 38
    • 1542542075 scopus 로고    scopus 로고
    • Doing more with less in the lab
    • Craig E. Doing more with less in the lab. MLO Med Lab Obs 2003;35:20-1.
    • (2003) MLO Med Lab Obs , vol.35 , pp. 20-21
    • Craig, E.1
  • 39
    • 0032162099 scopus 로고    scopus 로고
    • Robotics, automation, and the new role of process control
    • McPherson RA. Robotics, automation, and the new role of process control. Clin Lab Manage Rev 1998;12:339-46.
    • (1998) Clin Lab Manage Rev , vol.12 , pp. 339-346
    • McPherson, R.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.