메뉴 건너뛰기




Volumn 34, Issue 8, 2006, Pages 771-777

Refractory glaucoma - Tube or diode?

Author keywords

Molteno tube surgery; Refractory glaucoma; Trans scleral cyclodiode laser

Indexed keywords

ACETAZOLAMIDE; ANTIFIBROTIC AGENT; CHLORAMPHENICOL; COLCHICINE; DEXAMETHASONE; PIROXICAM; PREDNISOLONE; STEROID;

EID: 33750463748     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2006.01339.x     Document Type: Article
Times cited : (18)

References (29)
  • 1
    • 0031465059 scopus 로고    scopus 로고
    • Tube-shunt surgery versus Neodymium:YAG cyclophotocoagulation in the management of neovascular glaucoma
    • Eid TE, Katz LJ, Spaeth GL, Augsberger JJ. Tube-shunt surgery versus Neodymium:YAG cyclophotocoagulation in the management of neovascular glaucoma. Ophthalmology 1997; 104: 1692-700.
    • (1997) Ophthalmology , vol.104 , pp. 1692-1700
    • Eid, T.E.1    Katz, L.J.2    Spaeth, G.L.3    Augsberger, J.J.4
  • 2
    • 13144283612 scopus 로고    scopus 로고
    • Comparison of mitomycin C trabeculectomy, glaucoma drainage device implantation, and laser neodymium: YAG cyclophotocoagulation in the management of intractable glaucoma after penetrating keratoplasty
    • Ayyala RS, Pieroth L, Vinals AF et al. Comparison of mitomycin C trabeculectomy, glaucoma drainage device implantation, and laser neodymium: YAG cyclophotocoagulation in the management of intractable glaucoma after penetrating keratoplasty. Ophthalmology 1998; 105: 1550-6.
    • (1998) Ophthalmology , vol.105 , pp. 1550-1556
    • Ayyala, R.S.1    Pieroth, L.2    Vinals, A.F.3
  • 3
    • 0032212570 scopus 로고    scopus 로고
    • A clinical comparison of transscleral cyclophotocoagulation with neodymium: YAG and semiconductor diode lasers
    • Youn J, Cox TA, Herndon LW, Allingham RR, Shields MB. A clinical comparison of transscleral cyclophotocoagulation with neodymium: YAG and semiconductor diode lasers. Am J Ophthalmol 1998; 126: 640-7.
    • (1998) Am J Ophthalmol , vol.126 , pp. 640-647
    • Youn, J.1    Cox, T.A.2    Herndon, L.W.3    Allingham, R.R.4    Shields, M.B.5
  • 4
    • 0036952497 scopus 로고    scopus 로고
    • Transscleral diode laser contact cyclophotocoagulation in the treatment of different glaucomas, also as primary surgery
    • Kramp K, Hans-Peter V, Guthoff R. Transscleral diode laser contact cyclophotocoagulation in the treatment of different glaucomas, also as primary surgery. Graefes Arch Clin Exp Ophthalmol 2002; 240: 698-703.
    • (2002) Graefes Arch Clin Exp Ophthalmol , vol.240 , pp. 698-703
    • Kramp, K.1    Hans-Peter, V.2    Guthoff, R.3
  • 6
    • 0036222147 scopus 로고    scopus 로고
    • Pathology of cyclodiode laser: A series of nine enucleated eyes
    • McKelvie PA, Walland MJ. Pathology of cyclodiode laser: A series of nine enucleated eyes. Br J Ophthalmol 2002; 86: 381-6.
    • (2002) Br J Ophthalmol , vol.86 , pp. 381-386
    • McKelvie, P.A.1    Walland, M.J.2
  • 7
    • 0030433069 scopus 로고    scopus 로고
    • Semiconductor diode laser transscleral cyclophotocoagulation versus filtration surgery with Mitomycin-C
    • Pablo LE, Gomez ML, Pueyo M et al. Semiconductor diode laser transscleral cyclophotocoagulation versus filtration surgery with Mitomycin-C. Int Ophthalmol 1996; 20: 11-4.
    • (1996) Int Ophthalmol , vol.20 , pp. 11-14
    • Pablo, L.E.1    Gomez, M.L.2    Pueyo, M.3
  • 8
    • 0037528736 scopus 로고    scopus 로고
    • Molteno tube insertion avoiding complications
    • Morgan WH. Molteno tube insertion avoiding complications. Asia-Pacific J Ophthalmol 1996; 8: 7-9.
    • (1996) Asia-Pacific J Ophthalmol , vol.8 , pp. 7-9
    • Morgan, W.H.1
  • 9
    • 0037815332 scopus 로고    scopus 로고
    • Mitomycin C eliminates the short-term intraocular pressure rise following Molteno tube implantation
    • Ellingham RB, Morgan WH, Westlake W, House PH. Mitomycin C eliminates the short-term intraocular pressure rise following Molteno tube implantation. Clin Exp Ophthalmol 2003; 31: 191-8.
    • (2003) Clin Exp Ophthalmol , vol.31 , pp. 191-198
    • Ellingham, R.B.1    Morgan, W.H.2    Westlake, W.3    House, P.H.4
  • 10
    • 0031430961 scopus 로고    scopus 로고
    • 'Cyclodiode'. Trans-scleral diode laser cyclophotocoagulation in the treatment of advanced refractory glaucoma
    • Bloom PA, Tsai JC, Sharma K et al. 'Cyclodiode'. Trans-scleral diode laser cyclophotocoagulation in the treatment of advanced refractory glaucoma. Ophthalmology 1996; 104: 1508-20.
    • (1996) Ophthalmology , vol.104 , pp. 1508-1520
    • Bloom, P.A.1    Tsai, J.C.2    Sharma, K.3
  • 11
    • 0030793587 scopus 로고    scopus 로고
    • Transscleral diode laser cyclophotocoagulation for refractory paediatric glaucomas
    • Bock CJ, Freedman SF, Buckley EG, Shields MB. Transscleral diode laser cyclophotocoagulation for refractory paediatric glaucomas. J Paediatr Strabismus 1997; 34: 235-9.
    • (1997) J Paediatr Strabismus , vol.34 , pp. 235-239
    • Bock, C.J.1    Freedman, S.F.2    Buckley, E.G.3    Shields, M.B.4
  • 12
    • 0036151411 scopus 로고    scopus 로고
    • Diode laser cyclophotocoagulation: Role in the management of refractory paediatric glaucomas
    • Kirwan JF, Shah P, Khaw PT. Diode laser cyclophotocoagulation: Role in the management of refractory paediatric glaucomas. Ophthalmology 2002; 109: 316-23.
    • (2002) Ophthalmology , vol.109 , pp. 316-323
    • Kirwan, J.F.1    Shah, P.2    Khaw, P.T.3
  • 13
    • 0029841073 scopus 로고
    • Long-term outcome of initial ciliary ablation with contact diode transscleral cyclophotocoagulation for severe glaucoma
    • Kosoko O, Gaasterland DE, Pollack IP, Enger CL, the Diode Laser Ciliary Ablation Group. Long-term outcome of initial ciliary ablation with contact diode transscleral cyclophotocoagulation for severe glaucoma. Ophthalmology 1995; 103: 1294-302.
    • (1995) Ophthalmology , vol.103 , pp. 1294-1302
    • Kosoko, O.1    Gaasterland, D.E.2    Pollack, I.P.3    Enger, C.L.4
  • 14
    • 0034865133 scopus 로고    scopus 로고
    • Efficacy and safety of contact transscleral diode laser cycophotocoagulation for advanced glaucoma
    • Schlote T, Derse M, Rassmann K, Nicaeus T, Dietz K, Thiel HJ. Efficacy and safety of contact transscleral diode laser cycophotocoagulation for advanced glaucoma. J Glaucoma 2002; 10: 294-301.
    • (2002) J Glaucoma , vol.10 , pp. 294-301
    • Schlote, T.1    Derse, M.2    Rassmann, K.3    Nicaeus, T.4    Dietz, K.5    Thiel, H.J.6
  • 15
    • 0034767731 scopus 로고    scopus 로고
    • Cyclodiode photocoagulation for refractory glaucoma after penetrating keratoplasty
    • Shah P, Lee GA, Kirwan JK et al. Cyclodiode photocoagulation for refractory glaucoma after penetrating keratoplasty. Ophthalmology 2001; 108: 1986-91.
    • (2001) Ophthalmology , vol.108 , pp. 1986-1991
    • Shah, P.1    Lee, G.A.2    Kirwan, J.K.3
  • 16
    • 0033057148 scopus 로고    scopus 로고
    • 'Cyclodiode': Results of a standard protocol
    • Spencer AF, Vernon SA. 'Cyclodiode': Results of a standard protocol. Br J Ophthalmol 1999; 83: 311-6.
    • (1999) Br J Ophthalmol , vol.83 , pp. 311-316
    • Spencer, A.F.1    Vernon, S.A.2
  • 17
    • 0032471739 scopus 로고    scopus 로고
    • Intraocular pressure control after contact transscleral diode cyclophotocoagulation in eyes with intractable glaucoma
    • Yap-Veloso MIR, Simmons RB, Echelman DA, Gonzales TK, Veira WJ, Simmons RJ. Intraocular pressure control after contact transscleral diode cyclophotocoagulation in eyes with intractable glaucoma. J Glaucoma 1997; 7: 319-28.
    • (1997) J Glaucoma , vol.7 , pp. 319-328
    • Yap-Veloso, M.I.R.1    Simmons, R.B.2    Echelman, D.A.3    Gonzales, T.K.4    Veira, W.J.5    Simmons, R.J.6
  • 18
    • 0036022744 scopus 로고    scopus 로고
    • Influence of total energy delivery on success rate after contact diode laser transscleral cyclophotocoagulation: A retrospective case review and meta-analysis
    • Hauber FA, Scherer WJ. Influence of total energy delivery on success rate after contact diode laser transscleral cyclophotocoagulation: A retrospective case review and meta-analysis. J Glaucoma 2002; 11: 329-33.
    • (2002) J Glaucoma , vol.11 , pp. 329-333
    • Hauber, F.A.1    Scherer, W.J.2
  • 19
    • 0034979619 scopus 로고    scopus 로고
    • Survival analysis for success of Molteno tube implants
    • Broadway DC, Lester M, Schulzer M et al. Survival analysis for success of Molteno tube implants. Br J Ophthalmol 2001; 85: 689.
    • (2001) Br J Ophthalmol , vol.85 , pp. 689
    • Broadway, D.C.1    Lester, M.2    Schulzer, M.3
  • 20
    • 0027238059 scopus 로고
    • Molteno tube implantation for neovascular glaucoma: Long-term results and factors influencing outcome
    • Mermoud A, Salmon JF, Alexander P, Straker C, Murray AD. Molteno tube implantation for neovascular glaucoma: Long-term results and factors influencing outcome. Ophthalmology 1992; 100: 897-902.
    • (1992) Ophthalmology , vol.100 , pp. 897-902
    • Mermoud, A.1    Salmon, J.F.2    Alexander, P.3    Straker, C.4    Murray, A.D.5
  • 24
    • 0026771229 scopus 로고
    • Clinical experience with the single-plate Molteno implant in complicated glaucomas. Update of a pilot study
    • Lloyd MA, Sedlak T, Heuer DK et al. Clinical experience with the single-plate Molteno implant in complicated glaucomas. Update of a pilot study. Ophthalmology 1992; 99: 679-87.
    • (1992) Ophthalmology , vol.99 , pp. 679-687
    • Lloyd, M.A.1    Sedlak, T.2    Heuer, D.K.3
  • 25
    • 0000436514 scopus 로고    scopus 로고
    • Use of Molteno implants to treat secondary glaucoma
    • In: Cairns JE, ed. London: Grune & Stratton
    • Molteno ACB. Use of Molteno implants to treat secondary glaucoma. In: Cairns JE, ed. Glaucoma. London: Grune & Stratton, 1996; 221-38.
    • (1996) Glaucoma , pp. 221-238
    • Molteno, A.C.B.1
  • 26
    • 0029741013 scopus 로고    scopus 로고
    • Histolopathologic and immunohistochemical analysis of the filtration bleb after unsuccessful glaucoma Seton implantation
    • Classen L, Kivela T, Tarkkanen A. Histolopathologic and immunohistochemical analysis of the filtration bleb after unsuccessful glaucoma Seton implantation. Am J Ophthalmol 1996; 122: 205-12.
    • (1996) Am J Ophthalmol , vol.122 , pp. 205-212
    • Classen, L.1    Kivela, T.2    Tarkkanen, A.3
  • 27
    • 0028928217 scopus 로고
    • Contact transscleral cyclophotocoagulation with diode laser in refractory glaucoma
    • Brancato R, Carassa RG, Bettin P, Fiori M, Trabucchi G. Contact transscleral cyclophotocoagulation with diode laser in refractory glaucoma. Eur J Ophthalmol 1995; 5: 32-9.
    • (1995) Eur J Ophthalmol , vol.5 , pp. 32-39
    • Brancato, R.1    Carassa, R.G.2    Bettin, P.3    Fiori, M.4    Trabucchi, G.5
  • 29
    • 0032956965 scopus 로고    scopus 로고
    • Assessment of corneal decompensation in eyes having undergone Molteno shunt procedures compared to eyes having undergone trabeculectomy
    • Zalloum JN, Ahuja RM, Shin D, Weiss JS. Assessment of corneal decompensation in eyes having undergone Molteno shunt procedures compared to eyes having undergone trabeculectomy. CLAO J 1999; 25: 57-60.
    • (1999) CLAO J , vol.25 , pp. 57-60
    • Zalloum, J.N.1    Ahuja, R.M.2    Shin, D.3    Weiss, J.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.