-
2
-
-
9844266626
-
Demonstration der Nernstspaltlampe
-
Gullstrand A. Demonstration der Nernstspaltlampe. Ber Deutsch Ophthalmol Ges 37 (1911) 374-376
-
(1911)
Ber Deutsch Ophthalmol Ges
, vol.37
, pp. 374-376
-
-
Gullstrand, A.1
-
4
-
-
0035192810
-
Effect of acute biomechanical changes on corneal curvature after photokeratectomy
-
Dupps Jr. W.J., and Roberts C. Effect of acute biomechanical changes on corneal curvature after photokeratectomy. J Refract Surg 17 (2001) 658-669
-
(2001)
J Refract Surg
, vol.17
, pp. 658-669
-
-
Dupps Jr., W.J.1
Roberts, C.2
-
5
-
-
0026781152
-
The enigma of the corneal contour; Everett Kinsey Lecture
-
Mandell R.B. The enigma of the corneal contour; Everett Kinsey Lecture. CLAO J 18 (1992) 267-273
-
(1992)
CLAO J
, vol.18
, pp. 267-273
-
-
Mandell, R.B.1
-
6
-
-
0000695054
-
Measurements of the thickness of the cornea
-
discussion 265-266
-
von Bahr G. Measurements of the thickness of the cornea. Acta Ophthalmol 26 (1948) 247-265 discussion 265-266
-
(1948)
Acta Ophthalmol
, vol.26
, pp. 247-265
-
-
von Bahr, G.1
-
8
-
-
16344395137
-
Evaluation of apparent ectasia of the posterior surface of the cornea after keratorefractive surgery
-
Nawa Y., Masuda K., Ueda T., et al. Evaluation of apparent ectasia of the posterior surface of the cornea after keratorefractive surgery. J Cataract Refract Surg 31 (2005) 571-573
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 571-573
-
-
Nawa, Y.1
Masuda, K.2
Ueda, T.3
-
9
-
-
0027943021
-
The accuracy of 'power' maps to display curvature data in corneal topography systems
-
Roberts C. The accuracy of 'power' maps to display curvature data in corneal topography systems. Invest Ophthalmol Vis Sci 35 (1994) 3525-3532
-
(1994)
Invest Ophthalmol Vis Sci
, vol.35
, pp. 3525-3532
-
-
Roberts, C.1
-
10
-
-
0028397737
-
Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface
-
discussion by RB Mandell, RA Applegate, and reply by C Roberts, 112-116
-
Roberts C. Characterization of the inherent error in a spherically-biased corneal topography system in mapping a radially aspheric surface. J Refract Corneal Surg 10 (1994) 103-111 discussion by RB Mandell, RA Applegate, and reply by C Roberts, 112-116
-
(1994)
J Refract Corneal Surg
, vol.10
, pp. 103-111
-
-
Roberts, C.1
-
11
-
-
0028901048
-
Analysis of the inherent error of the TMS-1 Topographic Modeling System in mapping a radially aspheric surface
-
Roberts C. Analysis of the inherent error of the TMS-1 Topographic Modeling System in mapping a radially aspheric surface. Cornea 14 (1995) 258-265
-
(1995)
Cornea
, vol.14
, pp. 258-265
-
-
Roberts, C.1
-
12
-
-
0028880539
-
Accuracy of videokeratography for instantaneous radius in keratoconus
-
Chan J.S., Mandell R.B., Burger D.S., and Fusaro R.E. Accuracy of videokeratography for instantaneous radius in keratoconus. Optom Vis Sci 72 (1995) 793-799
-
(1995)
Optom Vis Sci
, vol.72
, pp. 793-799
-
-
Chan, J.S.1
Mandell, R.B.2
Burger, D.S.3
Fusaro, R.E.4
-
13
-
-
0029128440
-
Axial and instantaneous power conversion in corneal topography
-
Klein S.A., and Mandell R.B. Axial and instantaneous power conversion in corneal topography. Invest Ophthalmol Vis Sci 36 (1995) 2155-2159
-
(1995)
Invest Ophthalmol Vis Sci
, vol.36
, pp. 2155-2159
-
-
Klein, S.A.1
Mandell, R.B.2
-
14
-
-
0014561875
-
Keratoconus: spatial variation of corneal thickness as a diagnostic test
-
Mandell R.B., and Polse K.A. Keratoconus: spatial variation of corneal thickness as a diagnostic test. Arch Ophthalmol 82 (1969) 182-188
-
(1969)
Arch Ophthalmol
, vol.82
, pp. 182-188
-
-
Mandell, R.B.1
Polse, K.A.2
-
15
-
-
29344464132
-
Automated decision tree classification of corneal shape
-
Twa M.D., Parthasarathy S., Roberts C., et al. Automated decision tree classification of corneal shape. Optom Vis Sci 82 (2005) 1038-1046
-
(2005)
Optom Vis Sci
, vol.82
, pp. 1038-1046
-
-
Twa, M.D.1
Parthasarathy, S.2
Roberts, C.3
-
16
-
-
22144437405
-
Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye
-
Carvalho L.A. Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye. Invest Ophthalmol Vis Sci 46 (2005) 1915-1926
-
(2005)
Invest Ophthalmol Vis Sci
, vol.46
, pp. 1915-1926
-
-
Carvalho, L.A.1
-
17
-
-
33745428048
-
-
Ford M, Dupps WJ Jr, Huprikar N, et al. OCT corneal elastography by pressure-induced optical feature flow. In: Manns F, Söderberg PG, Ho A, eds, Ophthalmic Technologies XVI. Proceedings SPIE 6138. Bellingham WA, SPIE, 2006; 6138OP1-6138OP-7 (CID 6138OP. Abstract online at =http://spie.org/app/Publications/index.cfm?fuseaction=proceedings. Accessed March 7, 2006
-
-
-
|