메뉴 건너뛰기




Volumn 34, Issue 8, 2006, Pages 751-754

Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography

Author keywords

Cornea; Optical coherence tomography; Pachymetry; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; DIAGNOSTIC IMAGING; ECHOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; OPTICAL COHERENCE TOMOGRAPHY; RELIABILITY; ULTRASOUND PACHYMETRY;

EID: 33750455818     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2006.01343.x     Document Type: Article
Times cited : (52)

References (18)
  • 1
    • 0033759092 scopus 로고    scopus 로고
    • The repeatability of corneal thickness measures
    • Marsich MW, Bullimore MA. The repeatability of corneal thickness measures. Cornea 2000; 19: 792-5.
    • (2000) Cornea , vol.19 , pp. 792-795
    • Marsich, M.W.1    Bullimore, M.A.2
  • 2
    • 0032767869 scopus 로고    scopus 로고
    • Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system
    • Liu Z, Huang AJ, Pfugfelder SC. Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system. Br J Ophthalmol 1999; 83: 774-8.
    • (1999) Br J Ophthalmol , vol.83 , pp. 774-778
    • Liu, Z.1    Huang, A.J.2    Pfugfelder, S.C.3
  • 3
    • 0035171269 scopus 로고    scopus 로고
    • Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    • Bechman M, Thiel MJ, Neubauer AS et al. Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry. Cornea 2001; 20: 50-4.
    • (2001) Cornea , vol.20 , pp. 50-54
    • Bechman, M.1    Thiel, M.J.2    Neubauer, A.S.3
  • 4
    • 0030732383 scopus 로고    scopus 로고
    • Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes
    • Avitrabile T, Marano F, Uva MG et al. Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes. Cornea 1997; 16: 639-44.
    • (1997) Cornea , vol.16 , pp. 639-644
    • Avitrabile, T.1    Marano, F.2    Uva, M.G.3
  • 5
    • 0000816056 scopus 로고
    • Confocal microscopy of the eye
    • In: Masters BR, ed. New York, NY: Springer-Verlag NY Inc
    • Masters BR, Kino G. Confocal microscopy of the eye. In: Masters BR, ed. Noninvasive Diagnostic Techniques in Ophthalmology. New York, NY: Springer-Verlag NY Inc, 1990; 152-71.
    • (1990) Noninvasive Diagnostic Techniques in Ophthalmology , pp. 152-171
    • Masters, B.R.1    Kino, G.2
  • 6
    • 0034038860 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism
    • Maldonado MJ, Ruiz-Oblitas L, Munuera JM et al. Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism. Ophthalmology 2000; 107: 81-8.
    • (2000) Ophthalmology , vol.107 , pp. 81-88
    • Maldonado, M.J.1    Ruiz-Oblitas, L.2    Munuera, J.M.3
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 0030596840 scopus 로고    scopus 로고
    • Statistics notes: Measurement error
    • Bland JM, Altman DG. Statistics notes: Measurement error. BMJ 1996; 313: 744.
    • (1996) BMJ , vol.313 , pp. 744
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 4444279897 scopus 로고    scopus 로고
    • Clinical significance of central corneal thickness in the management of glaucoma
    • Shih CY, Graff Zivin JS, Trokel SL, Tsai JC. Clinical significance of central corneal thickness in the management of glaucoma. Arch Ophthalmol 2004; 122: 1270-5.
    • (2004) Arch Ophthalmol , vol.122 , pp. 1270-1275
    • Shih, C.Y.1    Graff Zivin, J.S.2    Trokel, S.L.3    Tsai, J.C.4
  • 11
    • 0035097379 scopus 로고    scopus 로고
    • Increased corneal thickness in patients with ocular hypertension
    • Herman DC, Hodge DO, Bourne WM et al. Increased corneal thickness in patients with ocular hypertension. Arch Ophthalmol 2001; 119: 334-6.
    • (2001) Arch Ophthalmol , vol.119 , pp. 334-336
    • Herman, D.C.1    Hodge, D.O.2    Bourne, W.M.3
  • 12
    • 0032006955 scopus 로고    scopus 로고
    • Corneal thickness and curvature in normal-tension glaucoma
    • Morad Y, Sharon E, Hefetz L et al. Corneal thickness and curvature in normal-tension glaucoma. Am J Ophthalmol 1998; 125: 164-8.
    • (1998) Am J Ophthalmol , vol.125 , pp. 164-168
    • Morad, Y.1    Sharon, E.2    Hefetz, L.3
  • 13
    • 7444237542 scopus 로고    scopus 로고
    • Central corneal pachymetry and visual field progression in patients with open-angle glaucoma
    • Kim JW, Chen PP. Central corneal pachymetry and visual field progression in patients with open-angle glaucoma. Ophthalmology 2004; 111: 2126-32.
    • (2004) Ophthalmology , vol.111 , pp. 2126-2132
    • Kim, J.W.1    Chen, P.P.2
  • 14
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the ocular hypertension treatment study (OHTS)
    • Brandt JD, Beiser JA, Kass MA et al. Central corneal thickness in the ocular hypertension treatment study (OHTS). Ophthalmology 2001; 108: 1779-88.
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Kass, M.A.3
  • 16
    • 0002999448 scopus 로고
    • Differences among ultrasonic pachymeters in measuring corneal thickness
    • Reader AL, Salz JJ. Differences among ultrasonic pachymeters in measuring corneal thickness. J Refract Surg 1987; 3: 7-11.
    • (1987) J Refract Surg , vol.3 , pp. 7-11
    • Reader, A.L.1    Salz, J.J.2
  • 17
    • 0036862048 scopus 로고    scopus 로고
    • Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    • Wong AC, Wong CC, Yuen NS et al. Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry. Eye 2002; 16: 715-21.
    • (2002) Eye , vol.16 , pp. 715-721
    • Wong, A.C.1    Wong, C.C.2    Yuen, N.S.3
  • 18
    • 19344369632 scopus 로고    scopus 로고
    • Assessment of central corneal thickness using optical coherence tomography
    • Fishman GR, Pons ME, Seedor JA et al. Assessment of central corneal thickness using optical coherence tomography. J Cataract Refract Surg 2005; 31: 707-11.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 707-711
    • Fishman, G.R.1    Pons, M.E.2    Seedor, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.