-
1
-
-
0034256544
-
Effects of different ventilation modes on respiratory mechanics and gas exchange of severe steam inhalation injury
-
Li G., Guo G., Xu C., et al. Effects of different ventilation modes on respiratory mechanics and gas exchange of severe steam inhalation injury. Zhong hua shao shang za zhi 16 3 (2000) 234-236
-
(2000)
Zhong hua shao shang za zhi
, vol.16
, Issue.3
, pp. 234-236
-
-
Li, G.1
Guo, G.2
Xu, C.3
-
2
-
-
0036594001
-
High frequency jet ventilation for treatment of severe burns accompanied by inhalation injury with ALI
-
Guo G., Li Y., Li Z., et al. High frequency jet ventilation for treatment of severe burns accompanied by inhalation injury with ALI. Zhong hua shao shang za zhi 18 6 (2002) 155-158
-
(2002)
Zhong hua shao shang za zhi
, vol.18
, Issue.6
, pp. 155-158
-
-
Guo, G.1
Li, Y.2
Li, Z.3
-
3
-
-
0031942649
-
Ventilator-induced lung injury: lessons from experimental studies
-
Dreyfess D., and Saumon G. Ventilator-induced lung injury: lessons from experimental studies. Am J Respir Crit Care Med 157 (1998) 294-323
-
(1998)
Am J Respir Crit Care Med
, vol.157
, pp. 294-323
-
-
Dreyfess, D.1
Saumon, G.2
-
5
-
-
0032772434
-
Lung injury caused by mechanical ventilation
-
Slutsky A.S. Lung injury caused by mechanical ventilation. Chest 116 (1999) 9s-15s
-
(1999)
Chest
, vol.116
-
-
Slutsky, A.S.1
-
6
-
-
0343893748
-
-
Acute Respiratory Distress syndrome Network. Ventilation with lower tidal volume compared with traditional tidal volumes for acute lung injury, and the acute respiratory distress syndrome. N Eng J Med 2000;342:1301-8.
-
-
-
-
7
-
-
0023268986
-
Ventilatory management of infant baboons with hyaline membrane disease: the use of high frequency ventilation
-
Delemos R.S., Coalson J.J., Gerstmann D.R., et al. Ventilatory management of infant baboons with hyaline membrane disease: the use of high frequency ventilation. Pediatr Res 21 (1987) 594-602
-
(1987)
Pediatr Res
, vol.21
, pp. 594-602
-
-
Delemos, R.S.1
Coalson, J.J.2
Gerstmann, D.R.3
-
8
-
-
0022382374
-
Effect of high frequency ventilation on gas exchange and pulmonary vascular resistance in lambs
-
Truog W.E., and Standaert T.A. Effect of high frequency ventilation on gas exchange and pulmonary vascular resistance in lambs. J Appl Physiol 59 (1985) 1104-1109
-
(1985)
J Appl Physiol
, vol.59
, pp. 1104-1109
-
-
Truog, W.E.1
Standaert, T.A.2
-
9
-
-
0001954641
-
High frequency oscillatory ventilation attenuates the activation of alveolar macrophages and neutrophils in lung injury
-
Shimaoka M., Fujino Y., Taenaka T., et al. High frequency oscillatory ventilation attenuates the activation of alveolar macrophages and neutrophils in lung injury. Crit Care 2 (1998) 35-39
-
(1998)
Crit Care
, vol.2
, pp. 35-39
-
-
Shimaoka, M.1
Fujino, Y.2
Taenaka, T.3
-
10
-
-
0028148259
-
Inflammatory chemical mediators during conventional ventilation and during high frequency oscillatory ventilation
-
Imai Y., Kawano T., Miyasaka K., et al. Inflammatory chemical mediators during conventional ventilation and during high frequency oscillatory ventilation. Am J Respir Crit Care Med 150 (1994) 1550-1554
-
(1994)
Am J Respir Crit Care Med
, vol.150
, pp. 1550-1554
-
-
Imai, Y.1
Kawano, T.2
Miyasaka, K.3
-
11
-
-
1642555875
-
High frequency oscillatory ventilation suppress inflammatory response in lung tissue and microdissected alveolar macrophages in surfactant depleted piglets
-
Vonder Hardt K., Kandler M.A., Fink L., et al. High frequency oscillatory ventilation suppress inflammatory response in lung tissue and microdissected alveolar macrophages in surfactant depleted piglets. Pediatr Res 55 2 (2004) 339-346
-
(2004)
Pediatr Res
, vol.55
, Issue.2
, pp. 339-346
-
-
Vonder Hardt, K.1
Kandler, M.A.2
Fink, L.3
-
12
-
-
33750455234
-
Introduction of a new steam scalding device with controlled thermal and pressure
-
Wang L., Liu D., Li G., et al. Introduction of a new steam scalding device with controlled thermal and pressure. J Jiangxi Med Coll 4 1 (2000) 7
-
(2000)
J Jiangxi Med Coll
, vol.4
, Issue.1
, pp. 7
-
-
Wang, L.1
Liu, D.2
Li, G.3
-
13
-
-
0032880553
-
The open lung during small tidal volume ventilation: concepts of recruitment and "optimal" positive end-expiratory pressure
-
Rimensberger Pc., Cxo P.N., Frndona H., et al. The open lung during small tidal volume ventilation: concepts of recruitment and "optimal" positive end-expiratory pressure. Crit Care Med 27 (1999) 1946-1952
-
(1999)
Crit Care Med
, vol.27
, pp. 1946-1952
-
-
Rimensberger, Pc.1
Cxo, P.N.2
Frndona, H.3
-
14
-
-
0036367257
-
Oxygenation index, an indicator of optimal distending pressure during high-frequency ventilation?
-
Huibert R., Johannus A., Jos R.C., et al. Oxygenation index, an indicator of optimal distending pressure during high-frequency ventilation?. Intensive Care Med 28 (2002) 1151-1156
-
(2002)
Intensive Care Med
, vol.28
, pp. 1151-1156
-
-
Huibert, R.1
Johannus, A.2
Jos, R.C.3
-
15
-
-
0035671010
-
Identification of optimal lung volume during high-frequency oscillatory ventilation using respiratory inductive plethysmography
-
Thomas B., Kenneth F., Maryanne Murphy B.A., et al. Identification of optimal lung volume during high-frequency oscillatory ventilation using respiratory inductive plethysmography. Crit Care Med 29 12 (2001) 2350-2360
-
(2001)
Crit Care Med
, vol.29
, Issue.12
, pp. 2350-2360
-
-
Thomas, B.1
Kenneth, F.2
Maryanne Murphy, B.A.3
-
16
-
-
0345283300
-
Setting mean airway pressure during high-frequency oscillatory ventilation according to the static pressure-volume curve in surfactant deficient lung injury
-
Thomas L., Juergen P., Peter H., et al. Setting mean airway pressure during high-frequency oscillatory ventilation according to the static pressure-volume curve in surfactant deficient lung injury. Anaesthesiology 99 6 (2003) 1313-1322
-
(2003)
Anaesthesiology
, vol.99
, Issue.6
, pp. 1313-1322
-
-
Thomas, L.1
Juergen, P.2
Peter, H.3
|