메뉴 건너뛰기




Volumn 53, Issue 5, 2006, Pages 2796-2807

Beam hardening correction for middle-energy industrial computerized tomography

Author keywords

Beam hardening correction; Cupping artifacts; Industrial computerized tomography; Linearization

Indexed keywords

BEAM HARDENING CORRECTION (BHC) METHOD; CUPPING ARTIFACTS; INDUSTRIAL COMPUTERIZED TOMOGRAPHY; SCALING FACTOR;

EID: 33750419609     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.879825     Document Type: Article
Times cited : (36)

References (29)
  • 3
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in X-ray computerized tomography
    • R. E. Alvarez and A. Macovski, "Energy-selective reconstructions in X-ray computerized tomography," Phys. Med. Biol., vol. 21, no. 5, pp. 733-744, 1976.
    • (1976) Phys. Med. Biol. , vol.21 , Issue.5 , pp. 733-744
    • Alvarez, R.E.1    Macovski, A.2
  • 4
    • 0034310513 scopus 로고    scopus 로고
    • Penalized weighted least-squares image reconstruction in single and dual energy X-ray computed tomography
    • Nov.
    • P. Sukovic and N. H. Clinthorne, "Penalized weighted least-squares image reconstruction in single and dual energy X-ray computed tomography," IEEE Trans. Med. Imag., vol. 19, no. 11, pp. 1075-1091, Nov. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.11 , pp. 1075-1091
    • Sukovic, P.1    Clinthorne, N.H.2
  • 6
    • 0017810277 scopus 로고
    • A method for correcting bone induced artifacts in computed tomography scanners
    • P. M. Joseph and R. D. Spital, "A method for correcting bone induced artifacts in computed tomography scanners," J. Comput. Assist. Tomogt., vol. 2, no. 1, pp. 100-108, 1978.
    • (1978) J. Comput. Assist. Tomogt. , vol.2 , Issue.1 , pp. 100-108
    • Joseph, P.M.1    Spital, R.D.2
  • 7
    • 0018404829 scopus 로고
    • Post-reconstruction method for beam hardening in computerized tomography
    • O. Nalcioglu and R. Y. Lou, "Post-reconstruction method for beam hardening in computerized tomography," Phys. Med. Biol., vol. 24, no. 2, pp. 330-340, 1979.
    • (1979) Phys. Med. Biol. , vol.24 , Issue.2 , pp. 330-340
    • Nalcioglu, O.1    Lou, R.Y.2
  • 8
    • 0030867231 scopus 로고    scopus 로고
    • A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine
    • Oct.
    • P. M. Joseph and C. Ruth, "A method for simultaneous correction of spectrum hardening artifacts in CT images containing both bone and iodine," Med. Phys., vol. 24, no. 10, pp. 1629-1634, Oct. 1997.
    • (1997) Med. Phys. , vol.24 , Issue.10 , pp. 1629-1634
    • Joseph, P.M.1    Ruth, C.2
  • 9
    • 0020813766 scopus 로고
    • A comparative study of two postreconstruction beam hardening correction methods
    • Sep.
    • G. T. Herman and S. S. Trivedi, "A comparative study of two postreconstruction beam hardening correction methods," IEEE Trans. Med. Imag., vol. MI-2, no. 3, pp. 128-135, Sep. 1983.
    • (1983) IEEE Trans. Med. Imag. , vol.MI-2 , Issue.3 , pp. 128-135
    • Herman, G.T.1    Trivedi, S.S.2
  • 10
    • 0025478201 scopus 로고
    • CT image correction for beam hardening using simulated projection data
    • Aug.
    • J. M. Meagher, C. D. Mote JR, and H. B. Skinner, "CT image correction for beam hardening using simulated projection data," IEEE Trans. Nucl. Sci., vol. 37, no. 4, pp. 1520-1524, Aug. 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , Issue.4 , pp. 1520-1524
    • Meagher, J.M.1    Mote Jr., C.D.2    Skinner, H.B.3
  • 11
    • 0033624949 scopus 로고    scopus 로고
    • Reconstruction algorithm for polychromatic CT imaging: Application to beam hardening correction
    • Jan.
    • C. H. Yan, R. T. Whalen, G. S. Beaupré, S. Y. Yen, and S. Napel, "Reconstruction algorithm for polychromatic CT imaging: Application to beam hardening correction," IEEE Trans. Med. Imag., vol. 19, no. 1, Jan. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.1
    • Yan, C.H.1    Whalen, R.T.2    Beaupré, G.S.3    Yen, S.Y.4    Napel, S.5
  • 12
    • 0035491479 scopus 로고    scopus 로고
    • An iterative maximum-likelihood polychromatic algorithm for CT
    • Oct.
    • B. De Man, J. Nuyts, P. Dupont, G. Marchai, and P. Suetens, "An iterative maximum-likelihood polychromatic algorithm for CT," IEEE Trans. Med. Imag., vol. 20, no. 10, pp. 999-1008, Oct. 2001.
    • (2001) IEEE Trans. Med. Imag. , vol.20 , Issue.10 , pp. 999-1008
    • De Man, B.1    Nuyts, J.2    Dupont, P.3    Marchai, G.4    Suetens, P.5
  • 13
    • 0036462553 scopus 로고    scopus 로고
    • Statistical image reconstruction for polyenergetic X-ray computed tomography
    • Feb.
    • I. A. Elbakri and J. A. Fessler, "Statistical image reconstruction for polyenergetic X-ray computed tomography," IEEE Trans. Med. Imag., vol. 21, no. 2, pp. 89-98, Feb. 2002.
    • (2002) IEEE Trans. Med. Imag. , vol.21 , Issue.2 , pp. 89-98
    • Elbakri, I.A.1    Fessler, J.A.2
  • 14
    • 0042977266 scopus 로고    scopus 로고
    • Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation
    • Aug.
    • I. A. Elbakri and J. A. Fessler, "Segmentation-free statistical image reconstruction for polyenergetic x-ray computed tomography with experimental validation," Phys. Med. Biol., vol. 48, no. 15, pp. 2453-2477, Aug. 2003.
    • (2003) Phys. Med. Biol. , vol.48 , Issue.15 , pp. 2453-2477
    • Elbakri, I.A.1    Fessler, J.A.2
  • 15
    • 15844405835 scopus 로고    scopus 로고
    • Eliminating beam-hardening artifacts in high-energy industrial computed tomography (ICT)
    • K. Kang, Z. Zhao, Z. Chen, and L. Zhang, "Eliminating beam-hardening artifacts in high-energy industrial computed tomography (ICT)," in Proc. SPIE, 2004, vol. 5535, pp. 765-774.
    • (2004) Proc. SPIE , vol.5535 , pp. 765-774
    • Kang, K.1    Zhao, Z.2    Chen, Z.3    Zhang, L.4
  • 16
    • 15844377059 scopus 로고    scopus 로고
    • Beam hardening correction and quantitative micro-CT
    • S. Prevrhal, "Beam hardening correction and quantitative micro-CT," in Proc. SPIE, 2004, vol. 5535, pp. 152-161.
    • (2004) Proc. SPIE , vol.5535 , pp. 152-161
    • Prevrhal, S.1
  • 17
    • 0017195533 scopus 로고
    • Beam hardening in X-ray reconstruction tomography
    • R. A. Brooks and G. D. Chiro, "Beam hardening in X-ray reconstruction tomography," Phys. Med. Biol., vol. 21, no. 3, pp. 390-398, 1976.
    • (1976) Phys. Med. Biol. , vol.21 , Issue.3 , pp. 390-398
    • Brooks, R.A.1    Chiro, G.D.2
  • 18
    • 0018386456 scopus 로고
    • Correction for beam hardening in computed tomography
    • G. T. Herman, "Correction for beam hardening in computed tomography," Phys. Med. Biol., vol. 24, no. 1, pp. 81-106, 1979.
    • (1979) Phys. Med. Biol. , vol.24 , Issue.1 , pp. 81-106
    • Herman, G.T.1
  • 19
    • 0012032351 scopus 로고    scopus 로고
    • Correction for beam hardening artefacts in computerised tomography
    • P. Hammersberg and M. Mangard, "Correction for beam hardening artefacts in computerised tomography," J. X-ray Sci. Technol., vol. 8, no. 1, pp. 75-93, 1998.
    • (1998) J. X-ray Sci. Technol. , vol.8 , Issue.1 , pp. 75-93
    • Hammersberg, P.1    Mangard, M.2
  • 20
    • 0033983855 scopus 로고    scopus 로고
    • An iterative approach to the beam hardening correction in cone beam CT
    • Jan.
    • J. Hsieh, R. C. Molthen, C. A. Dawson, and R. H. Johnson, "An iterative approach to the beam hardening correction in cone beam CT," Med. Phys., vol. 27, no. 1, pp. 23-29, Jan. 2000.
    • (2000) Med. Phys. , vol.27 , Issue.1 , pp. 23-29
    • Hsieh, J.1    Molthen, R.C.2    Dawson, C.A.3    Johnson, R.H.4
  • 21
    • 0037038947 scopus 로고    scopus 로고
    • An energy-based beam hardening model in tomography
    • Dec.
    • E. V. de Casteele, D. V. Dyck, J. Sijbers, and E. Raman, "An energy-based beam hardening model in tomography," Phys, Med, Biol., vol. 47, no. 7, pp. 4181-4190, Dec. 2002.
    • (2002) Phys, Med, Biol. , vol.47 , Issue.7 , pp. 4181-4190
    • De Casteele, E.V.1    Dyck, D.V.2    Sijbers, J.3    Raman, E.4
  • 22
    • 2542464481 scopus 로고    scopus 로고
    • A model-based correction method for beam hardening artefacts in X-ray micro-tomography
    • E. V. de Casteele, D. V. Dyck, J. Sijbers, and E. Raman, "A model-based correction method for beam hardening artefacts in X-ray micro-tomography," J. X-ray Sci. Technol., vol. 12, no. 1, pp. 43-57, 2004.
    • (2004) J. X-ray Sci. Technol. , vol.12 , Issue.1 , pp. 43-57
    • De Casteele, E.V.1    Dyck, D.V.2    Sijbers, J.3    Raman, E.4
  • 24
    • 0019496952 scopus 로고
    • Definitions of effective energy in computed tomography
    • P. S. Tofts, "Definitions of effective energy in computed tomography," Phys. Med. Biol., vol. 26, no. 2, pp. 313-317, 1981.
    • (1981) Phys. Med. Biol. , vol.26 , Issue.2 , pp. 313-317
    • Tofts, P.S.1
  • 26
    • 0021445363 scopus 로고
    • Practical cone-beam algorithm
    • Jun.
    • L. A. Feldkamp, L. C. Davis, and J. W. Kress, "Practical cone-beam algorithm," J. Opt. Soc. Amer., vol. 1, no. 6, pp. 612-619, Jun. 1984.
    • (1984) J. Opt. Soc. Amer. , vol.1 , Issue.6 , pp. 612-619
    • Feldkamp, L.A.1    Davis, L.C.2    Kress, J.W.3
  • 27
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • May
    • R. Ning and X. Tang, "X-ray scatter correction algorithm for cone beam CT imaging," Med. Phys., vol. 31, no. 5, pp. 1195-1202, May 2004.
    • (2004) Med. Phys. , vol.31 , Issue.5 , pp. 1195-1202
    • Ning, R.1    Tang, X.2
  • 28
    • 33645655309 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    • to be published
    • S. Li, L. Zhang, Z. Chen, and H. Gao, "X-ray scatter correction algorithm for 450 KeV cone-beam CT system," Nucl. Electron. Detection Technol., to be published.
    • Nucl. Electron. Detection Technol.
    • Li, S.1    Zhang, L.2    Chen, Z.3    Gao, H.4
  • 29
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses
    • Dec.
    • S. Zhao, D. D. Robertson, G. Wang, B. Whiting, and K. T. Bae, "X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses," IEEE Trans. Med. Imag., vol. 19, no. 12, pp. 1238-1247, Dec. 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.12 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.