Volumn 53, Issue 5, 2006, Pages 3021-3027

New readout electronics for 3-D position sensitive CdZnTe/HgI2 detector arrays

Author keywords

Array; CdZnTe; CZT; Position sensitive; Readout; Spectrometer; Three dimensional (3 D)

Indexed keywords

APPLICATION SPECIFIC INTEGRATED CIRCUITS; MICROPROCESSOR CHIPS; RADIATION DETECTORS; SPECTROMETERS; THREE DIMENSIONAL;

EID: 33750386608     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.879761     Document Type: Article
Times cited : (43)

References (12)
  • 1
    • 0029357607 scopus 로고
    • Unipolar charge sensing with coplanar electrodes - Application to semiconductor detectors
    • P. N. Luke, "Unipolar charge sensing with coplanar electrodes - Application to semiconductor detectors," IEEE Trans. Nucl, Sci., vol. 42, pp. 207-213, 1995.
    • (1995) IEEE Trans. Nucl, Sci. , vol.42 , pp. 207-213
    • Luke, P.N.1
  • 3
    • 4244180299 scopus 로고
    • Charge transport in arrays of semiconductor gamma-ray detectors
    • H. H. Barrett, J. D. Eskin, and H. B. Barber, "Charge transport in arrays of semiconductor gamma-ray detectors." Phys. Rev. Lett., vol. 75, pp. 156-159, 1995.
    • (1995) Phys. Rev. Lett. , vol.75 , pp. 156-159
    • Barrett, H.H.1    Eskin, J.D.2    Barber, H.B.3
  • 4
    • 0041424861 scopus 로고    scopus 로고
    • Spectroscopy on thick HgI2 detectors: A comparison between planar and pixelated electrodes
    • J. E. Baciak and Z. He, "Spectroscopy on thick HgI2 detectors: A comparison between planar and pixelated electrodes." IEEE Trans. Nucl. Sci., vol. 50, pp. 1220-1224, 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 1220-1224
    • Baciak, J.E.1    He, Z.2
  • 5
    • 0033314607 scopus 로고    scopus 로고
    • A data acquisition and processing system for 3-D position sensitive CZT gamma-ray spectrometers
    • W. Li, Z. He, G. F. Knoll, D. K. Wehe, and J. E. Berry, "A data acquisition and processing system for 3-D position sensitive CZT gamma-ray spectrometers," IEEE Trans. Nucl. Sci., vol. 46, pp. 1989-1994, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 1989-1994
    • Li, W.1    He, Z.2    Knoll, G.F.3    Wehe, D.K.4    Berry, J.E.5
  • 7
    • 8344265385 scopus 로고    scopus 로고
    • Improved resolution for 3D position sensitive CdZnTe spectrometers
    • F. Zhang, Z. He, D. Xu, G. F. Knoll, D. K. Wehe, and J. E. Berry, "Improved resolution for 3D position sensitive CdZnTe spectrometers," IEEE Trans. Nucl. Sci., vol. 51, pp. 2427-2431, 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2427-2431
    • Zhang, F.1    He, Z.2    Xu, D.3    Knoll, G.F.4    Wehe, D.K.5    Berry, J.E.6
  • 8
    • 15844397625 scopus 로고    scopus 로고
    • 3D position sensitive CdZnTe gamma-ray spectrometers - Improved performance with new ASICs
    • F. Zhang and Z. He, "3D position sensitive CdZnTe gamma-ray spectrometers - improved performance with new ASICs," in Proc. SPIE, 2004, vol. 5540.
    • (2004) Proc. SPIE , vol.5540
    • Zhang, F.1    He, Z.2
  • 9
    • 29144508741 scopus 로고    scopus 로고
    • 3D position sensitive CdZnTe spectrometer performance using third generation VAS/TAT readout electronics
    • F. Zhang, Z. He, G. F. Knoll, D. K. Wehe, and J. E. Berry, "3D position sensitive CdZnTe spectrometer performance using third generation VAS/TAT readout electronics," IEEE Trans. Nucl. Sci., vol. 52, pp. 2009-2016, 2005.
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , pp. 2009-2016
    • Zhang, F.1    He, Z.2    Knoll, G.F.3    Wehe, D.K.4    Berry, J.E.5
  • 10
    • 0042928055 scopus 로고    scopus 로고
    • Intelligent gamma-ray spectroscopy using 3-D position-sensitive detectors
    • C. E. Lehner, Z. He, and G. F. Knoll, "Intelligent gamma-ray spectroscopy using 3-D position-sensitive detectors," IEEE Trans. Nucl. Sci., vol. 50, pp. 1090-1097, 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 1090-1097
    • Lehner, C.E.1    He, Z.2    Knoll, G.F.3
  • 11
    • 4444249595 scopus 로고    scopus 로고
    • 4π compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood
    • C. E. Lehner, Z. He, and F. Zhang, "4π compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood," IEEE Trans. Nucl. Sci., vol. 51, pp. 1618-1624, 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 1618-1624
    • Lehner, C.E.1    He, Z.2    Zhang, F.3
  • 12
    • 15844414532 scopus 로고    scopus 로고
    • 4-pi Compton imaging with single 3D position sensitive CdZnTe detector
    • D. Xu, Z. He, C. E. Lehner, and F. Zhang, "4-pi Compton imaging with single 3D position sensitive CdZnTe detector," in Proc. SPIE, 2004, vol. 5540.
    • (2004) Proc. SPIE , vol.5540
    • Xu, D.1    He, Z.2    Lehner, C.E.3    Zhang, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.