-
1
-
-
0019523331
-
In vivo neutron activation analysis: State of the art and future prospects
-
S. H. Cohn, "In vivo neutron activation analysis: State of the art and future prospects," Med. Phys., vol. 8, pp. 145-154, 1981.
-
(1981)
Med. Phys.
, vol.8
, pp. 145-154
-
-
Cohn, S.H.1
-
2
-
-
0021637916
-
Techniques of in vivo neutron activation analysis
-
D. R. Chettle and J. H. Fremlin, 'Techniques of in vivo neutron activation analysis," Phys. Med. Biol., vol. 29, pp. 1011-1043, 1984.
-
(1984)
Phys. Med. Biol.
, vol.29
, pp. 1011-1043
-
-
Chettle, D.R.1
Fremlin, J.H.2
-
3
-
-
0023722668
-
In vivo monitoring of skeletal aluminum burden in patients with renal failure
-
K. J. Ellis, S. Kelleher, A. Raciti, J. Savory, and M. Wills, "In vivo monitoring of skeletal aluminum burden in patients with renal failure," J. Radioanal. Nucl. Chem. Artic., vol. 124, pp. 85-95, 1988.
-
(1988)
J. Radioanal. Nucl. Chem. Artic.
, vol.124
, pp. 85-95
-
-
Ellis, K.J.1
Kelleher, S.2
Raciti, A.3
Savory, J.4
Wills, M.5
-
4
-
-
0026678475
-
A feasibility study of the in vivo measurement of aluminium in peripheral bone
-
S. Green and D. R. Chettle, "A feasibility study of the in vivo measurement of aluminium in peripheral bone," Phys. Med. Biol., vol. 37, pp. 2287-2296, 1992.
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 2287-2296
-
-
Green, S.1
Chettle, D.R.2
-
5
-
-
0027359448
-
The development of a technique to measure bone aluminium content using neutron activation analysis
-
R. M. Wyatt, S. J. S. Ryde, W. D. Morgan, E. A. McNeil, I. R. Hainsworth, and A. J. Williams, "The development of a technique to measure bone aluminium content using neutron activation analysis," Physiol. Meas., vol. 14, pp. 327-335, 1993.
-
(1993)
Physiol. Meas.
, vol.14
, pp. 327-335
-
-
Wyatt, R.M.1
Ryde, S.J.S.2
Morgan, W.D.3
McNeil, E.A.4
Hainsworth, I.R.5
Williams, A.J.6
-
6
-
-
0032080034
-
Development of an accelerator based determination of aluminum burden in peripheral bone by neutron activation analysis
-
A. Pejović-Milić, F. E. McNeill, W. V. Prestwich, A. J. Waker, and D. R. Chettle, "Development of an accelerator based determination of aluminum burden in peripheral bone by neutron activation analysis," Appl. Radiat. Isot., vol. 49, pp. 717-719, 1998.
-
(1998)
Appl. Radiat. Isot.
, vol.49
, pp. 717-719
-
-
Pejović-Milić, A.1
McNeill, F.E.2
Prestwich, W.V.3
Waker, A.J.4
Chettle, D.R.5
-
7
-
-
0036852644
-
An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones
-
M. L. Arnold, F. E. McNeill, I. M. Stronach, A. Pejović- Milić, D. R. Chettle, and A. J. Waker, "An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones," Med. Phys., vol. 29, pp. 2718-2724, 2002.
-
(2002)
Med. Phys.
, vol.29
, pp. 2718-2724
-
-
Arnold, M.L.1
McNeill, F.E.2
Stronach, I.M.3
Pejović-Milić, A.4
Chettle, D.R.5
Waker, A.J.6
-
8
-
-
4544242409
-
Application of spectral decomposition analysis to in vivo quantification of aluminum by neutron activation analysis
-
D. C. Comsa, W. V. Prestwich, F. E. McNeill, and S. H. Byun, "Application of spectral decomposition analysis to in vivo quantification of aluminum by neutron activation analysis," Appl. Radiat. Isot., vol. 61, pp. 1353-1360, 2004.
-
(2004)
Appl. Radiat. Isot.
, vol.61
, pp. 1353-1360
-
-
Comsa, D.C.1
Prestwich, W.V.2
McNeill, F.E.3
Byun, S.H.4
-
9
-
-
9944239288
-
Efficiency calibration and coincidence summing correction for a 4 π NaI(Tl) detector array
-
S. H. Byun, W. V. Prestwich, K. Chin, F. E. McNeill, and D. R. Chettle, "Efficiency calibration and coincidence summing correction for a 4 π NaI(Tl) detector array," Nucl. Intstrum. Methods Phys. Res. A, vol. A535, pp. 674-685, 2004.
-
(2004)
Nucl. Intstrum. Methods Phys. Res. A
, vol.A535
, pp. 674-685
-
-
Byun, S.H.1
Prestwich, W.V.2
Chin, K.3
McNeill, F.E.4
Chettle, D.R.5
-
11
-
-
0037118483
-
Energy resolution and light yield non-proportionality of pure NaI scintillator studied with large area avalanche photodiodes at liquid nitrogen temperatures
-
M. Moszyński, W. Czarnacki, M. Kapusta, M. Szawlowski, W. Klamra, and P. Schotanus, "Energy resolution and light yield non-proportionality of pure NaI scintillator studied with large area avalanche photodiodes at liquid nitrogen temperatures," Nucl. Intstrum. Methods Phys. Res. A, vol. 486, pp. 13-17, 2002.
-
(2002)
Nucl. Intstrum. Methods Phys. Res. A
, vol.486
, pp. 13-17
-
-
Moszyński, M.1
Czarnacki, W.2
Kapusta, M.3
Szawlowski, M.4
Klamra, W.5
Schotanus, P.6
-
12
-
-
0342626747
-
Monte Carlo design study for in vivo bone aluminum measurement using a low energy accelerator beam
-
A. Pejović-Milić, M. L. Arnold, F. E. McNeill, and D. R. Chettle, "Monte Carlo design study for in vivo bone aluminum measurement using a low energy accelerator beam," Appl. Radiat. Isot., vol. 53, pp. 657-664, 2000.
-
(2000)
Appl. Radiat. Isot.
, vol.53
, pp. 657-664
-
-
Pejović-Milić, A.1
Arnold, M.L.2
McNeill, F.E.3
Chettle, D.R.4
|