메뉴 건너뛰기




Volumn 24, Issue 4, 2006, Pages 448-452

A novel method of producing a repetitive dynamic signal to examine reliability and validity of gait analysis systems

Author keywords

Gait; Kinematics; Locomotion; Motion analysis; Reproducibility of results

Indexed keywords

ARTICLE; COMPARATIVE STUDY; DATA ANALYSIS; GAIT; KINEMATICS; LOCOMOTION; MEASUREMENT; MOTION ANALYSIS SYSTEM; PRIORITY JOURNAL; REPRODUCIBILITY; TEST RETEST RELIABILITY; VALIDITY;

EID: 33750370481     PISSN: 09666362     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2005.09.008     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 33749261687 scopus 로고
    • Goals of gait assessment
    • Craik R.L., and Oatis C.A. (Eds), Mosby, St. Louis, MO
    • Oatis C.A. Goals of gait assessment. In: Craik R.L., and Oatis C.A. (Eds). Gait analysis: theory and application (1995), Mosby, St. Louis, MO 328-333
    • (1995) Gait analysis: theory and application , pp. 328-333
    • Oatis, C.A.1
  • 2
    • 33750341766 scopus 로고    scopus 로고
    • Results: Basic measurement accuracy, and processing time. Paper presented at Comparison Meeting of Motion Analysis Systems 2002. Tokyo, Japan: Japan Technology College, 2002.
  • 5
    • 0024764105 scopus 로고
    • Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
    • Kadaba M., Ramakrishnan H., Wootten M., Gainey J., Gorton G., and Cochran G. Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait. J Orthop Res 7 6 (1989) 849-860
    • (1989) J Orthop Res , vol.7 , Issue.6 , pp. 849-860
    • Kadaba, M.1    Ramakrishnan, H.2    Wootten, M.3    Gainey, J.4    Gorton, G.5    Cochran, G.6
  • 6
    • 0021179349 scopus 로고
    • Kinematic and kinetic patterns in human gait: variability and compensating effects
    • Winter D. Kinematic and kinetic patterns in human gait: variability and compensating effects. Hum Movement Sci 3 (1984) 51-76
    • (1984) Hum Movement Sci , vol.3 , pp. 51-76
    • Winter, D.1
  • 7
    • 33748275430 scopus 로고    scopus 로고
    • Concurrent validity of GAITRite and PEAK Motus motion analysis systems
    • Cutlip R., DiPasquale J., Huber F., et al. Concurrent validity of GAITRite and PEAK Motus motion analysis systems. Section Res Newslett 30 3 (1998) 13
    • (1998) Section Res Newslett , vol.30 , Issue.3 , pp. 13
    • Cutlip, R.1    DiPasquale, J.2    Huber, F.3
  • 8
    • 0035096375 scopus 로고    scopus 로고
    • The validity and reliability of the GAITRite system's measurements: a preliminary evaluation
    • McDonough A., Batavia M., Chen F., Kwon S., and Ziai J. The validity and reliability of the GAITRite system's measurements: a preliminary evaluation. Arch Phys Med Rehabil 82 (March 2001) 419-425
    • (2001) Arch Phys Med Rehabil , vol.82 , pp. 419-425
    • McDonough, A.1    Batavia, M.2    Chen, F.3    Kwon, S.4    Ziai, J.5
  • 9
    • 0037305703 scopus 로고    scopus 로고
    • Concurrent related validity of the GAITRite walkway system for quantification of the spatial and temporal parameters of gait
    • Bilney B., Morris M., and Webster K. Concurrent related validity of the GAITRite walkway system for quantification of the spatial and temporal parameters of gait. Gait Posture 17 February (1) (2003) 68-74
    • (2003) Gait Posture , vol.17 , Issue.February 1 , pp. 68-74
    • Bilney, B.1    Morris, M.2    Webster, K.3
  • 10
    • 2942525667 scopus 로고    scopus 로고
    • Reliability of the GAITRite walkway system for the quantification of temporo-spatial parameters of gait in young and older people
    • Menz H., Latt M., Tiedemann A., Mun San Kwan M., and Lord S. Reliability of the GAITRite walkway system for the quantification of temporo-spatial parameters of gait in young and older people. Gait Posture 20 August (1) (2004) 20-25
    • (2004) Gait Posture , vol.20 , Issue.August 1 , pp. 20-25
    • Menz, H.1    Latt, M.2    Tiedemann, A.3    Mun San Kwan, M.4    Lord, S.5
  • 11
    • 0028304371 scopus 로고
    • Retest reliability of the temporal and distance characteristics of hemiplegic gait using a footswitch system
    • Hill K., Goldie P., Baker P., and Greenwood K. Retest reliability of the temporal and distance characteristics of hemiplegic gait using a footswitch system. Arch Phys Med Rehabil 75 (1994) 577-583
    • (1994) Arch Phys Med Rehabil , vol.75 , pp. 577-583
    • Hill, K.1    Goldie, P.2    Baker, P.3    Greenwood, K.4
  • 12
    • 0030835526 scopus 로고    scopus 로고
    • Systematic and random error in repeated measurements of temporal and distance parameters of gait after stroke
    • Evans M., Goldie P., and Hill K. Systematic and random error in repeated measurements of temporal and distance parameters of gait after stroke. Arch Phys Med Rehabil 78 July (7) (1997) 725-729
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.July 7 , pp. 725-729
    • Evans, M.1    Goldie, P.2    Hill, K.3
  • 13
    • 33748273824 scopus 로고    scopus 로고
    • Reliability and concurrent validity of the Gait Grid Mat for assessing selected gait parameters in healthy subjects
    • [Fall/Winter]
    • Cuffia B., Palmer C., Pierce S., Schaumberg S., and Wellmon R. Reliability and concurrent validity of the Gait Grid Mat for assessing selected gait parameters in healthy subjects. Section Res Newslett (1997) [Fall/Winter]
    • (1997) Section Res Newslett
    • Cuffia, B.1    Palmer, C.2    Pierce, S.3    Schaumberg, S.4    Wellmon, R.5
  • 14
    • 1542610706 scopus 로고    scopus 로고
    • Reliability of measurement of temp-spatial parameters of gait after stroke using GaitMat II
    • Pomeroy V., Chambers S., Giakas G., and Bland M. Reliability of measurement of temp-spatial parameters of gait after stroke using GaitMat II. Clin Rehabil 18 (2004) 222-227
    • (2004) Clin Rehabil , vol.18 , pp. 222-227
    • Pomeroy, V.1    Chambers, S.2    Giakas, G.3    Bland, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.