메뉴 건너뛰기




Volumn 7, Issue 2, 2006, Pages 58-63

The dosimetric effect of inhomogeneity correction in dynamic conformal arc stereotactic body radiation therapy for lung tumors

Author keywords

Equivalent uniform dose; Inhomogeneity correction; Lung tumors; Stereotactic body radiation therapy (SBRT)

Indexed keywords

ALGORITHM; ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER SIMULATION; HUMAN; LUNG TUMOR; METHODOLOGY; RADIATION DOSE; RADIATION RESPONSE; RADIOMETRY; RADIOSURGERY;

EID: 33750333392     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v7i2.2236     Document Type: Article
Times cited : (12)

References (9)
  • 1
    • 7444253462 scopus 로고    scopus 로고
    • American Society of Therapeutic Radiology and Oncology, American College of Radiology practice guidelines for the performance of stereotactic body radiation therapy
    • Potters L, Steinberg M, Rose C, et al American Society of Therapeutic Radiology and Oncology, American College of Radiology practice guidelines for the performance of stereotactic body radiation therapy. Int J Radiat Oncol Biol Phys. 2004;60(4):1026-1032.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , Issue.4 , pp. 1026-1032
    • Potters, L.1    Steinberg, M.2    Rose, C.3
  • 2
    • 34548201615 scopus 로고    scopus 로고
    • A phase I trial of stereotactic body radiation therapy (SBRT) for lung metastases; manuscript in revision
    • Schefter TE, Kavanagh BD, Raben D. A phase I trial of stereotactic body radiation therapy (SBRT) for lung metastases; manuscript in revision. Int J Radiat Oncol Biol Phys. 2006.
    • (2006) Int J Radiat Oncol Biol Phys
    • Schefter, T.E.1    Kavanagh, B.D.2    Raben, D.3
  • 3
    • 0141611848 scopus 로고    scopus 로고
    • How should we describe the radiobiologic effect of extracranial stereotactic radiosurgery: Equivalent uniform dose or tumor control probability?
    • Kavanagh BD, Timmerman RD, Benedict SH, et al. How should we describe the radiobiologic effect of extracranial stereotactic radiosurgery: Equivalent uniform dose or tumor control probability? Med Phys. 2003;30(3):321-324.
    • (2003) Med Phys , vol.30 , Issue.3 , pp. 321-324
    • Kavanagh, B.D.1    Timmerman, R.D.2    Benedict, S.H.3
  • 4
    • 0031037018 scopus 로고    scopus 로고
    • Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    • Niemierko A. Reporting and analyzing dose distributions: A concept of equivalent uniform dose. Med Phys. 1997;24(1):103-110.
    • (1997) Med Phys , vol.24 , Issue.1 , pp. 103-110
    • Niemierko, A.1
  • 5
    • 85024981915 scopus 로고    scopus 로고
    • Applying the equivalent uniform dose formulation based on the linear-quadratic model to inhomogeneous tumor dose distributions: Caution for analyzing and reporting
    • McGary JE, Grant W 3rd, Woo SY. Applying the equivalent uniform dose formulation based on the linear-quadratic model to inhomogeneous tumor dose distributions: Caution for analyzing and reporting. J Appl Clin Med Phys. 2000;1(4):126-137.
    • (2000) J Appl Clin Med Phys , vol.1 , Issue.4 , pp. 126-137
    • McGary, J.E.1    Grant 3rd, W.2    Woo, S.Y.3
  • 6
    • 0034827572 scopus 로고    scopus 로고
    • Monte Carlo dose verification for intensity-modulated arc therapy
    • Li XA, Ma L, Naqvi S, Shih R, Yu C. Monte Carlo dose verification for intensity-modulated arc therapy. Phys Med Biol. 2001;46(9):2269-2292.
    • (2001) Phys Med Biol , vol.46 , Issue.9 , pp. 2269-2292
    • Li, X.A.1    Ma, L.2    Naqvi, S.3    Shih, R.4    Yu, C.5
  • 7
    • 11144340904 scopus 로고    scopus 로고
    • Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets
    • Haedinger U, Krieger T, Flentje M, Wulf J. Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets. Int J Radiat Oncol Biol Phys. 2005;61(1):239-249.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , Issue.1 , pp. 239-249
    • Haedinger, U.1    Krieger, T.2    Flentje, M.3    Wulf, J.4
  • 8
    • 27144445265 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: Phase I study
    • McGarry RC, Papiez L, Williams M, Whitford T, Timmerman RD. Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: Phase I study. Int J Radiat Oncol Biol Phys. 2005;63(4):1010-1015.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , Issue.4 , pp. 1010-1015
    • McGarry, R.C.1    Papiez, L.2    Williams, M.3    Whitford, T.4    Timmerman, R.D.5
  • 9
    • 0033855418 scopus 로고    scopus 로고
    • Heterogeneity corrections should be used in treatment planning for lung cancer
    • Papanikolaou N, Klein EE. Heterogeneity corrections should be used in treatment planning for lung cancer. Med Phys. 2000;27(8):1702-1704.
    • (2000) Med Phys , vol.27 , Issue.8 , pp. 1702-1704
    • Papanikolaou, N.1    Klein, E.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.