메뉴 건너뛰기




Volumn 33, Issue 11, 2006, Pages 1314-1320

Intracoronary β-brachytherapy using a rhenium-188 filled balloon catheter in restenotic lesions of native coronary arteries and venous bypass grafts

Author keywords

Brachytherapy; Coronary heart disease; Restenotic lesion; Rhenium 188

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; HEPARIN; RHENIUM 188;

EID: 33750314005     PISSN: 16197070     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-006-0142-2     Document Type: Article
Times cited : (6)

References (25)
  • 1
    • 20244377701 scopus 로고    scopus 로고
    • Guidelines for percutaneous coronary interventions
    • The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology
    • Silber S, Albertsson P, Avilés FF, Camici PG, Colombo A, Hamm C, et al. Guidelines for percutaneous coronary interventions. The Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology. Eur Heart J 2005;26:804-847
    • (2005) Eur Heart J , vol.26 , pp. 804-847
    • Silber, S.1    Albertsson, P.2    Avilés, F.F.3    Camici, P.G.4    Colombo, A.5    Hamm, C.6
  • 2
    • 0037062647 scopus 로고    scopus 로고
    • Five-year clinical follow-up after intracoronary radiation. Results of a randomized clinical trial
    • Grise MA, Massullo V, Jani S, Popma JJ, Russo RJ, Schatz RA, et al. Five-year clinical follow-up after intracoronary radiation. Results of a randomized clinical trial. Circulation 2002;105:2737-2740
    • (2002) Circulation , vol.105 , pp. 2737-2740
    • Grise, M.A.1    Massullo, V.2    Jani, S.3    Popma, J.J.4    Russo, R.J.5    Schatz, R.A.6
  • 3
    • 0034142223 scopus 로고    scopus 로고
    • Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial
    • Teirstein PS, Massullo V, Jani S, Popma JJ, Russo RJ, Schatz RA, et al. Three-year clinical and angiographic follow-up after intracoronary radiation: results of a randomized clinical trial. Circulation 2000;101:360-365
    • (2000) Circulation , vol.101 , pp. 360-365
    • Teirstein, P.S.1    Massullo, V.2    Jani, S.3    Popma, J.J.4    Russo, R.J.5    Schatz, R.A.6
  • 4
    • 0038677078 scopus 로고    scopus 로고
    • Intracoronary beta-irradiation with a rhenium-188-filled balloon catheter: A randomized trial in patients with de novo and restenotic lesions
    • Höher M, Wöhrle J, Wohlfrom M, Kamenz J, Nusser T, Grebe OC, et al. Intracoronary beta-irradiation with a rhenium-188-filled balloon catheter: a randomized trial in patients with de novo and restenotic lesions. Circulation 2003;107:3022-3027
    • (2003) Circulation , vol.107 , pp. 3022-3027
    • Höher, M.1    Wöhrle, J.2    Wohlfrom, M.3    Kamenz, J.4    Nusser, T.5    Grebe, O.C.6
  • 5
  • 6
    • 0037129429 scopus 로고    scopus 로고
    • Intravascular gamma radiation for in-stent restenosis in saphenous-vein bypass grafts
    • Waksman R, Ajani AE, White RL, Chan RC, Satler LF, Kent KM, et al. Intravascular gamma radiation for in-stent restenosis in saphenous-vein bypass grafts. N Engl J Med 2002;346:1194-1199
    • (2002) N Engl J Med , vol.346 , pp. 1194-1199
    • Waksman, R.1    Ajani, A.E.2    White, R.L.3    Chan, R.C.4    Satler, L.F.5    Kent, K.M.6
  • 7
    • 2442691301 scopus 로고    scopus 로고
    • Intracoronary radiotherapy with a (188) rhenium liquid-filled PTCA balloon system in in-stent restenosis: Acute and long-term angiographic results, as well as 1-year clinical follow-up
    • Reynen K, Kockeritz U, Kropp J, Wunderlich G, Knapp FF, Schmeisser A, et al. Intracoronary radiotherapy with a (188) rhenium liquid-filled PTCA balloon system in in-stent restenosis: acute and long-term angiographic results, as well as 1-year clinical follow-up. Int J Cardiol 2004;95:29-34
    • (2004) Int J Cardiol , vol.95 , pp. 29-34
    • Reynen, K.1    Kockeritz, U.2    Kropp, J.3    Wunderlich, G.4    Knapp, F.F.5    Schmeisser, A.6
  • 8
    • 0034847202 scopus 로고    scopus 로고
    • Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon
    • Park SW, Hong MK, Moon DH, Oh SJ, Lee CW, Kim JJ, et al. Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon. J Am Coll Cardiol 2001;38:631-637
    • (2001) J Am Coll Cardiol , vol.38 , pp. 631-637
    • Park, S.W.1    Hong, M.K.2    Moon, D.H.3    Oh, S.J.4    Lee, C.W.5    Kim, J.J.6
  • 10
    • 3042709028 scopus 로고    scopus 로고
    • Three-year clinical follow-up results of intracoronary radiation therapy using a rhenium-188-diethylene-triamine-penta-acetic-acid-filled balloon system
    • Kim KI, Bae J, Kang HJ, Koo BK, Youn TJ, Kim SH, et al. Three-year clinical follow-up results of intracoronary radiation therapy using a rhenium-188-diethylene-triamine-penta-acetic-acid-filled balloon system. Circ J 2004;68:532-537
    • (2004) Circ J , vol.68 , pp. 532-537
    • Kim, K.I.1    Bae, J.2    Kang, H.J.3    Koo, B.K.4    Youn, T.J.5    Kim, S.H.6
  • 13
    • 0035945667 scopus 로고    scopus 로고
    • Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting
    • Leon MB, Teirstein PS, Moses JW, Tripuraneni P, Lansky AJ, Jani S, et al. Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting. N Engl J Med 2001;344:250-256
    • (2001) N Engl J Med , vol.344 , pp. 250-256
    • Leon, M.B.1    Teirstein, P.S.2    Moses, J.W.3    Tripuraneni, P.4    Lansky, A.J.5    Jani, S.6
  • 14
    • 0034625080 scopus 로고    scopus 로고
    • Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis
    • Waksman R, White RL, Chan RC, Bass BG, Geirlach L, Mintz GS, et al. Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis. Circulation 2000;101:2165-2171
    • (2000) Circulation , vol.101 , pp. 2165-2171
    • Waksman, R.1    White, R.L.2    Chan, R.C.3    Bass, B.G.4    Geirlach, L.5    Mintz, G.S.6
  • 15
    • 0037426377 scopus 로고    scopus 로고
    • Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) studies
    • Waksman R, Cheneau E, Ajani AE, White L, Pinnow E, Torguson R, et al. Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) studies. Circulation 2003;107:1744-1749
    • (2003) Circulation , vol.107 , pp. 1744-1749
    • Waksman, R.1    Cheneau, E.2    Ajani, A.E.3    White, L.4    Pinnow, E.5    Torguson, R.6
  • 17
    • 17544400054 scopus 로고    scopus 로고
    • Intracoronary β-radiation therapy inhibits recurrence of in-stent restenosis
    • Waksman R, Bhargava B, White L, Chan RC, Mehran R, Lansky AJ, et al. Intracoronary β-radiation therapy inhibits recurrence of in-stent restenosis. Circulation 2000;101:1895-1898
    • (2000) Circulation , vol.101 , pp. 1895-1898
    • Waksman, R.1    Bhargava, B.2    White, L.3    Chan, R.C.4    Mehran, R.5    Lansky, A.J.6
  • 20
    • 24944444303 scopus 로고    scopus 로고
    • Comparison of angiographic and clinical outcomes between rotational atherectomy and cutting balloon angioplasty followed by radiation therapy with a rhenium 188-mercaptoacetyltriglycine-filled balloon in the treatment of diffuse in-stent restenosis
    • Lee SW, Park SW, Hong MK, Kim YH, Han KH, Moon DH, et al. Comparison of angiographic and clinical outcomes between rotational atherectomy and cutting balloon angioplasty followed by radiation therapy with a rhenium 188-mercaptoacetyltriglycine-filled balloon in the treatment of diffuse in-stent restenosis. Am Heart J 2005;150:577-582
    • (2005) Am Heart J , vol.150 , pp. 577-582
    • Lee, S.W.1    Park, S.W.2    Hong, M.K.3    Kim, Y.H.4    Han, K.H.5    Moon, D.H.6
  • 21
    • 10744226664 scopus 로고    scopus 로고
    • Clinical outcome following combination of cutting balloon angioplasty and coronary β-radiation for instent restenosis: A report from the RENO registry
    • Roguelov C, Eeckhout E, De Benedetti E, Coucke P, Silber S, Baumgart D, et al. Clinical outcome following combination of cutting balloon angioplasty and coronary β-radiation for instent restenosis: a report from the RENO registry. J Invas Cardiol 2003;15:706-709
    • (2003) J Invas Cardiol , vol.15 , pp. 706-709
    • Roguelov, C.1    Eeckhout, E.2    De Benedetti, E.3    Coucke, P.4    Silber, S.5    Baumgart, D.6
  • 22
    • 0032011212 scopus 로고    scopus 로고
    • Dosimetry fundamentals of endovascular therapy using Re-188 for the prevention of restenosis after angioplasty
    • Kotzerke J, Rentschler M, Glatting G, Schneider E, Stabin M, Knapp FF Jr, et al. Dosimetry fundamentals of endovascular therapy using Re-188 for the prevention of restenosis after angioplasty. Nuklearmedizin 1998;37:68-72
    • (1998) Nuklearmedizin , vol.37 , pp. 68-72
    • Kotzerke, J.1    Rentschler, M.2    Glatting, G.3    Schneider, E.4    Stabin, M.5    Knapp Jr., F.F.6
  • 23
    • 0033970289 scopus 로고    scopus 로고
    • Endovascular brachytherapy for the prevention of restenosis after angioplasty
    • Kotzerke J, Hanke H, Höher M. Endovascular brachytherapy for the prevention of restenosis after angioplasty. Eur J Nucl Med 2000;27:223-236
    • (2000) Eur J Nucl Med , vol.27 , pp. 223-236
    • Kotzerke, J.1    Hanke, H.2    Höher, M.3
  • 24
    • 10744225735 scopus 로고    scopus 로고
    • Comparison of the angiographic outcomes after beta versus gamma vascular brachytherapy for treatment of in-stent restenosis
    • Shirai K, Lansky AJ, Mintz GS, Costantini CO, Fahy M, Mehran R, et al. Comparison of the angiographic outcomes after beta versus gamma vascular brachytherapy for treatment of in-stent restenosis. Am J Cardiol 2003;92:1409-1413
    • (2003) Am J Cardiol , vol.92 , pp. 1409-1413
    • Shirai, K.1    Lansky, A.J.2    Mintz, G.S.3    Costantini, C.O.4    Fahy, M.5    Mehran, R.6
  • 25
    • 0037320142 scopus 로고    scopus 로고
    • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner
    • Wuu CS, Schiff P, Maryanski MJ, Liu T, Borzillary S, Weinberger J. Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner. Med Phys 2003;130:132-137
    • (2003) Med Phys , vol.130 , pp. 132-137
    • Wuu, C.S.1    Schiff, P.2    Maryanski, M.J.3    Liu, T.4    Borzillary, S.5    Weinberger, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.