메뉴 건너뛰기




Volumn 126, Issue 10, 2006, Pages

A method for balancing between supply and demand based on distributed autonomous operation of an isolated system in FRIENDS

Author keywords

FRIENDS; Governor free; Isolated system; Load frequency control; QCC

Indexed keywords

ELECTRIC ENERGY STORAGE; ELECTRIC FREQUENCY CONTROL; ELECTRIC LOADS; ELECTRIC POWER DISTRIBUTION;

EID: 33750297640     PISSN: 03854213     EISSN: 13488147     Source Type: Journal    
DOI: 10.1541/ieejpes.126.1039     Document Type: Article
Times cited : (3)

References (14)
  • 1
    • 84961716389 scopus 로고    scopus 로고
    • Trends and forecasts for novel electric neiwork-central remarks
    • (3) (in Japanese)
    • A. Yokoyama: 'Trends and Forecasts for Novel Electric Neiwork-Central Remarks - ", J. IEE Japan, Vol.125, No.3, pp. 145-148 (2005-3) (in Japanese)
    • (2005) J. IEE Japan , vol.125 , Issue.3 , pp. 145-148
    • Yokoyama, A.1
  • 2
    • 0011756389 scopus 로고    scopus 로고
    • A new flexible, reliable and intelligent electric energy delivery system
    • (1) (in Japanese)
    • K. Nara and J. Hasegawa: "A New Flexible, Reliable and Intelligent Electric Energy Delivery System", T. IEE Japan, Vol.117, No.1, pp.47-53 (1997-1) (in Japanese)
    • (1997) T. IEE Japan , vol.117 , Issue.1 , pp. 47-53
    • Nara, K.1    Hasegawa, J.2
  • 3
    • 52349111397 scopus 로고    scopus 로고
    • A real-time pricing system for DSM in FRIENDS
    • (12) (in Japanese)
    • S. Yoshikawa, H. Kita, E. Tanaka, and J. Hasegawa: "A Real-time Pricing System for DSM in FRIENDS", IEEJ Trans. PE, Vol.125, No. 12, pp. 1137-1146 (2005-12) (in Japanese)
    • (2005) IEEJ Trans. PE , vol.125 , Issue.12 , pp. 1137-1146
    • Yoshikawa, S.1    Kita, H.2    Tanaka, E.3    Hasegawa, J.4
  • 4
    • 0011753807 scopus 로고    scopus 로고
    • Interior structure of quality control center at the low voltage side for the customized power quality service in FRIENDS
    • (11) (in Japanese)
    • R. Hara, H. Kita, E. Tanaka, and J, Hasegawa: "Interior Structure of Quality Control Center at the Low Voltage Side for the Customized Power Quality Service in FRIENDS", T. IEE Japan, Vol. 120-B, No.11, pp.1451-1458 (2000-11) (in Japanese)
    • (2000) T. IEE Japan , vol.120 B , Issue.11 , pp. 1451-1458
    • Hara, R.1    Kita, H.2    Tanaka, E.3    Hasegawa, J.4
  • 5
    • 0347084282 scopus 로고    scopus 로고
    • Interior structure of quality control center at the low voltage side considering the power conditioning by SMES
    • (10) (in Japanese)
    • T. Sasaki, R. Hara, H. Kita, E. Tanaka, and J. Hasegawa: "Interior Structure of Quality Control Center at the Low Voltage Side Considering the Power Conditioning by SMES", T. IEE Japan, Vol.121-B, No.10, pp.1353-1360 (2001-10) (in Japanese)
    • (2001) T. IEE Japan , vol.121 B , Issue.10 , pp. 1353-1360
    • Sasaki, T.1    Hara, R.2    Kita, H.3    Tanaka, E.4    Hasegawa, J.5
  • 6
    • 33750374762 scopus 로고    scopus 로고
    • Advanced solid-state switching using a novel hybrid switch device
    • M. Takeda, H. Yamamoto, and G.F. Reed: "Advanced Solid-State Switching Using a Novel Hybrid Switch Device", Proc. of Power Quality '98, pp.49-60 (1998)
    • (1998) Proc. of Power Quality '98 , pp. 49-60
    • Takeda, M.1    Yamamoto, H.2    Reed, G.F.3
  • 7
    • 85010174765 scopus 로고    scopus 로고
    • A study on transfer switching in consideration of fault detection in FRIENDS
    • (3) (in Japanese)
    • T. Suzuki, R. Hara, H. Kita, E. Tanaka, J. Hasegowa, and I. Iyoda: "A Study on Transfer Switching in Consideration of Fault Detection in FRIENDS", IEEJ Trans. PE. Vol.123, No.3, pp.324-332 (2003-3) (in Japanese)
    • (2003) IEEJ Trans. PE. , vol.123 , Issue.3 , pp. 324-332
    • Suzuki, T.1    Hara, R.2    Kita, H.3    Tanaka, E.4    Hasegowa, J.5    Iyoda, I.6
  • 8
    • 32144447038 scopus 로고    scopus 로고
    • The electric power system technique for effective use of the dispersed generation
    • in Japanese
    • "The electric power system technique for effective use of the dispersed generation", Technical Report of IEEJ, No.1025 (2005) (in Japanese)
    • (2005) Technical Report of IEEJ , Issue.1025
  • 11
    • 33750332706 scopus 로고    scopus 로고
    • An investigation on the interior structure of quality control center in FRIENDS - Control scheme considering the function of low volage side
    • (3) (in Japanese)
    • R. Hara, H. Kita, E. Tanaka, and J. Hasegawa: "An Investigation on the Interior Structure of Quality Control Center in FRIENDS - Control Scheme Considering the Function of Low Volage Side - ", 2000 National Convention Record IEE Japan, No.6, pp.2773-2774 (2000-3) (in Japanese)
    • (2000) 2000 National Convention Record IEE Japan , Issue.6 , pp. 2773-2774
    • Hara, R.1    Kita, H.2    Tanaka, E.3    Hasegawa, J.4
  • 12
    • 0037720653 scopus 로고    scopus 로고
    • Unbundled power quality supply system with three-phase four-wire ac system
    • (12) (in Japanese)
    • Y. Hayashi, T. Ise, and K. Tuji: "Unbundled Power Quality Supply System with Three-Phase Four-Wire ac System", T. IEE Japan, Vol.121-B, No.12, pp.1776-1787 (2001-12) (in Japanese)
    • (2001) T. IEE Japan , vol.121 B , Issue.12 , pp. 1776-1787
    • Hayashi, Y.1    Ise, T.2    Tuji, K.3
  • 13
    • 1442287831 scopus 로고    scopus 로고
    • Evaluation study about Redox flow battery response and its modeling
    • (4) (in Japanese)
    • K. Enomoto, T. Sasaki, T. Shigematsu, and H. Deguchi: "Evaluation study about Redox flow battery response and its modeling", T. IEE Japan, Vol.122-B, No.4, pp.554-560 (2002-4) (in Japanese)
    • (2002) T. IEE Japan , vol.122 B , Issue.4 , pp. 554-560
    • Enomoto, K.1    Sasaki, T.2    Shigematsu, T.3    Deguchi, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.