메뉴 건너뛰기




Volumn 90, Issue 10, 2006, Pages 1292-1296

Remote image based retinopathy of prematurity diagnosis: A receiver operating characteristic analysis of accuracy

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CAMERA; DIAGNOSTIC ACCURACY; HOSPITALIZATION; HUMAN; IMAGE ANALYSIS; INFANT; MAJOR CLINICAL STUDY; OPHTHALMOSCOPY; PRIORITY JOURNAL; READING; RETROLENTAL FIBROPLASIA; SENSITIVITY AND SPECIFICITY;

EID: 33750284621     PISSN: 00071161     EISSN: None     Source Type: Journal    
DOI: 10.1136/bjo.2006.091900     Document Type: Article
Times cited : (61)

References (20)
  • 1
    • 0031869207 scopus 로고    scopus 로고
    • Telemedicine: Where it is and where it's going
    • Grigsby J, Sanders JH. Telemedicine: where it is and where it's going. Ann Intern Med 1998;129:123-7.
    • (1998) Ann Intern Med , vol.129 , pp. 123-127
    • Grigsby, J.1    Sanders, J.H.2
  • 4
    • 0035080167 scopus 로고    scopus 로고
    • Childhood blindness in the context of Vision 2020: The right to sight
    • Gilbert C, Foster A. Childhood blindness in the context of Vision 2020: the right to sight. Bull World Health Organ 2001;79:227-32.
    • (2001) Bull World Health Organ , vol.79 , pp. 227-232
    • Gilbert, C.1    Foster, A.2
  • 5
    • 0034861464 scopus 로고    scopus 로고
    • Screening examination of premature infants for retinopathy of prematurity
    • Fierson WM, Palmer EA, Petersen RA, et al. Screening examination of premature infants for retinopathy of prematurity. Pediatrics 2001;108:809-11.
    • (2001) Pediatrics , vol.108 , pp. 809-811
    • Fierson, W.M.1    Palmer, E.A.2    Petersen, R.A.3
  • 6
    • 0021243811 scopus 로고
    • An international classification of retinopathy of prematurity
    • Committee for the Classification of Retinopathy Of Prematurity
    • Committee for the Classification of Retinopathy Of Prematurity. An international classification of retinopathy of prematurity. Arch Ophthalmol 1984;102:1130-4.
    • (1984) Arch Ophthalmol , vol.102 , pp. 1130-1134
  • 7
    • 0023914308 scopus 로고
    • Multicenter trial of cryotherapy for retinopathy of prematurity: Preliminary results
    • Cryotherapy for Retinopathy of Prematurity Cooperative Group
    • Cryotherapy for Retinopathy of Prematurity Cooperative Group. Multicenter trial of cryotherapy for retinopathy of prematurity: preliminary results. Arch Ophthalmol 1988;106:471-9.
    • (1988) Arch Ophthalmol , vol.106 , pp. 471-479
  • 8
    • 0345189363 scopus 로고    scopus 로고
    • Revised indications for the treatment of retinopathy of prematurity: Results of the early treatment for retinopathy of prematurity randomized trial
    • Early Treatment for Retinopathy of Prematurity Cooperative Group
    • Early Treatment for Retinopathy of Prematurity Cooperative Group. Revised indications for the treatment of retinopathy of prematurity: results of the early treatment for retinopathy of prematurity randomized trial. Arch Ophthalmol 2003;121:1684-94.
    • (2003) Arch Ophthalmol , vol.121 , pp. 1684-1694
  • 9
    • 0034127808 scopus 로고    scopus 로고
    • Telemedical evaluation and management of retinopathy of prematurity using a fiberoptic digital fundus camera
    • Schwartz SD, Harrison SA, Ferrone PJ, et al. Telemedical evaluation and management of retinopathy of prematurity using a fiberoptic digital fundus camera. Ophthalmology 2000;107:25-8.
    • (2000) Ophthalmology , vol.107 , pp. 25-28
    • Schwartz, S.D.1    Harrison, S.A.2    Ferrone, P.J.3
  • 10
    • 0242317878 scopus 로고    scopus 로고
    • Telemedicine approach to screening for severe retinopathy of prematurity: A pilot study
    • Ells AL, Holmes JM, Astle WF, et al. Telemedicine approach to screening for severe retinopathy of prematurity: a pilot study. Ophthalmology 2003;110:2113-17.
    • (2003) Ophthalmology , vol.110 , pp. 2113-2117
    • Ells, A.L.1    Holmes, J.M.2    Astle, W.F.3
  • 11
    • 33644912891 scopus 로고    scopus 로고
    • Accuracy and reliability of remote retinopathy of prematurity diagnosis
    • Chiang MF, Keenan JD, Starren J, et al. Accuracy and reliability of remote retinopathy of prematurity diagnosis. Arch Ophthalmol 2006;124:322-7.
    • (2006) Arch Ophthalmol , vol.124 , pp. 322-327
    • Chiang, M.F.1    Keenan, J.D.2    Starren, J.3
  • 12
    • 33750351049 scopus 로고    scopus 로고
    • Assessment of image-based technology: Impact of referral cutoff on accuracy and reliability of remote retinopathy of prematurity diagnosis
    • Chiang MF, Keenan JD, Du YE, et al. Assessment of image-based technology: impact of referral cutoff on accuracy and reliability of remote retinopathy of prematurity diagnosis. Proc AMIA Symp 2005:126-30.
    • (2005) Proc AMIA Symp , pp. 126-130
    • Chiang, M.F.1    Keenan, J.D.2    Du, Y.E.3
  • 13
    • 0035121957 scopus 로고    scopus 로고
    • Screening for retinopathy of prematurity employing the RetCam 120: Sensitivity and specificity
    • Roth DB, Morales D, Feuer WJ, et al. Screening for retinopathy of prematurity employing the RetCam 120: sensitivity and specificity. Arch Ophthalmol 2001;119:268-72.
    • (2001) Arch Ophthalmol , vol.119 , pp. 268-272
    • Roth, D.B.1    Morales, D.2    Feuer, W.J.3
  • 14
    • 0036549359 scopus 로고    scopus 로고
    • Telephotoscreening to detect retinopathy of prematurity: Preliminary study of the optimum time to employ digital fundus camera imaging to detect ROP
    • Yen KG, Hess D, Burke B, et al. Telephotoscreening to detect retinopathy of prematurity: preliminary study of the optimum time to employ digital fundus camera imaging to detect ROP. J AAPOS 2002;6:64-70.
    • (2002) J AAPOS , vol.6 , pp. 64-70
    • Yen, K.G.1    Hess, D.2    Burke, B.3
  • 15
    • 0015240858 scopus 로고
    • Signal detectability and medical decision-making
    • Lusted LB. Signal detectability and medical decision-making. Science 1971;171:1217-9.
    • (1971) Science , vol.171 , pp. 1217-1219
    • Lusted, L.B.1
  • 16
    • 0023890867 scopus 로고
    • Measuring the accuracy of diagnostic systems
    • Swets JA. Measuring the accuracy of diagnostic systems. Science 1988;240:1285-93.
    • (1988) Science , vol.240 , pp. 1285-1293
    • Swets, J.A.1
  • 17
    • 0027457620 scopus 로고
    • Receiver-operating characteristic (ROC) plots: A fundamental evaluation tool in clinical medicine
    • Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem 1993;39:561-77.
    • (1993) Clin Chem , vol.39 , pp. 561-577
    • Zweig, M.H.1    Campbell, G.2
  • 18
    • 0141518516 scopus 로고    scopus 로고
    • Receiver operating characteristic curves and their use in radiology
    • Obuchowski NA. Receiver operating characteristic curves and their use in radiology. Radiology 2003;229:3-8.
    • (2003) Radiology , vol.229 , pp. 3-8
    • Obuchowski, N.A.1
  • 19
    • 0030840310 scopus 로고    scopus 로고
    • Sensitivity and specificity of optic disc variables and analysis of a new variable (MP/D) for glaucoma diagnosis with the Glaucoma-Scope
    • Lachkar Y, Cohn H. Sensitivity and specificity of optic disc variables and analysis of a new variable (MP/D) for glaucoma diagnosis with the Glaucoma-Scope. Br J Ophthalmol 1997;81:846-51.
    • (1997) Br J Ophthalmol , vol.81 , pp. 846-851
    • Lachkar, Y.1    Cohn, H.2
  • 20
    • 0036176276 scopus 로고    scopus 로고
    • Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish Interactive Threshold Algorithm-fast perimetry in a glaucoma practice
    • Wadood AC, Azuara-Blanco A, Aspinall P, et al. Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish Interactive Threshold Algorithm-fast perimetry in a glaucoma practice. Am J Ophthalmol 2002;133:327-32.
    • (2002) Am J Ophthalmol , vol.133 , pp. 327-332
    • Wadood, A.C.1    Azuara-Blanco, A.2    Aspinall, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.