메뉴 건너뛰기




Volumn 29, Issue 3, 2006, Pages 272-277

Comparison of skin dose between conventional radiotherapy and IMRT

Author keywords

IMRT; Radiochromic film; Surface dose

Indexed keywords

CONTAMINATION; DOSIMETERS; DRUG DOSAGE; IONIZING RADIATION; LINEAR ACCELERATORS; SKIN; THIN FILMS;

EID: 33750192371     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178577     Document Type: Article
Times cited : (22)

References (9)
  • 2
    • 0347625752 scopus 로고    scopus 로고
    • Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays
    • Dogan, N., and Glasgow, G., Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays, Med. Phys., 30(12): 3091-3096, 2003.
    • (2003) Med. Phys. , vol.30 , Issue.12 , pp. 3091-3096
    • Dogan, N.1    Glasgow, G.2
  • 3
    • 8544280002 scopus 로고    scopus 로고
    • The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT)
    • Thomas, S. J. and Hoole, A. C., The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT), Phys. Med. Biol., 49(21): 4919-28, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , Issue.21 , pp. 4919-4928
    • Thomas, S.J.1    Hoole, A.C.2
  • 4
    • 14544282452 scopus 로고    scopus 로고
    • Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head-and-neck treatments
    • Paelinck, L., De Wagter, C., Van Esch, A., Duthoy, W., Depuydt, T., and De Neve, W., Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head-and-neck treatments, Phys. Med. Biol., 50(3): 413-428, 2005.
    • (2005) Phys. Med. Biol. , vol.50 , Issue.3 , pp. 413-428
    • Paelinck, L.1    De Wagter, C.2    Van Esch, A.3    Duthoy, W.4    Depuydt, T.5    De Neve, W.6
  • 6
    • 0033015509 scopus 로고    scopus 로고
    • Extrapolated surface dose measurements with radiochromic film
    • Butson, M., Yu, P., and Metcalfe, P., Extrapolated surface dose measurements with radiochromic film, Med. Phys., 26(3): 485-488, 1999.
    • (1999) Med. Phys. , vol.26 , Issue.3 , pp. 485-488
    • Butson, M.1    Yu, P.2    Metcalfe, P.3
  • 7
    • 85024973127 scopus 로고    scopus 로고
    • Validation of physics improvements for IMRT with a commercial treatment planning system
    • Cadman, P., McNutt, T., Bzdusek, K., Validation of physics improvements for IMRT with a commercial treatment planning system, J Appl. Clin. Med. Phys., 6(2): 74-86, 2005.
    • (2005) J Appl. Clin. Med. Phys. , vol.6 , Issue.2 , pp. 74-86
    • Cadman, P.1    McNutt, T.2    Bzdusek, K.3
  • 8
    • 0035661179 scopus 로고    scopus 로고
    • A Monte Carlo study of radiation transport through multileaf collimators
    • Kim, J. O., Siebers, J. V., Keall, P. J., Arnfield, M. R. and Mohan R. A Monte Carlo study of radiation transport through multileaf collimators, Med. Phys 28(12): 2497-506, 2001.
    • (2001) Med. Phys , vol.28 , Issue.12 , pp. 2497-2506
    • Kim, J.O.1    Siebers, J.V.2    Keall, P.J.3    Arnfield, M.R.4    Mohan, R.5
  • 9
    • 0037035317 scopus 로고    scopus 로고
    • Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator
    • Ding, G. X., Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator, Phys. Med. Biol., 47(7):1025-46, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , Issue.7 , pp. 1025-1046
    • Ding, G.X.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.