메뉴 건너뛰기




Volumn 14, Issue 9, 2006, Pages 865-868

Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction

Author keywords

Anterior cruciate ligament reconstruction; Bioabsorbable interference screw; Complication; Intraarticular migration

Indexed keywords

LACTIC ACID; POLYLACTIC ACID; POLYMER;

EID: 33750188985     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-006-0049-2     Document Type: Article
Times cited : (45)

References (22)
  • 1
    • 0032962290 scopus 로고    scopus 로고
    • Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation
    • Barber FA (1999) Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation. Arthroscopy 15:360-367
    • (1999) Arthroscopy , vol.15 , pp. 360-367
    • Barber, F.A.1
  • 3
    • 0029021799 scopus 로고
    • Endobutton endoscopic fixation technique in anterior cruciate ligament reconstruction
    • Barrett GR, Papendick L, Miller C (1995) Endobutton endoscopic fixation technique in anterior cruciate ligament reconstruction. Arthroscopy 11:340-343
    • (1995) Arthroscopy , vol.11 , pp. 340-343
    • Barrett, G.R.1    Papendick, L.2    Miller, C.3
  • 4
    • 0033985852 scopus 로고    scopus 로고
    • A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial
    • Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41-48
    • (2000) Arthroscopy , vol.16 , pp. 41-48
    • Benedetto, K.P.1    Fellinger, M.2    Lim, T.E.3    Passler, J.M.4    Schoen, J.L.5    Willems, W.J.6
  • 5
    • 0034068873 scopus 로고    scopus 로고
    • An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction
    • Bottoni C, DeBerardino T, Fester E, Mitchell D, Penrod BJ (2000) An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction. Arthroscopy 16:395-398
    • (2000) Arthroscopy , vol.16 , pp. 395-398
    • Bottoni, C.1    DeBerardino, T.2    Fester, E.3    Mitchell, D.4    Penrod, B.J.5
  • 6
    • 0032324720 scopus 로고    scopus 로고
    • Migration of femoral interference screw after anterior cruciate ligament reconstruction
    • Bush-Joseph CA, Bach BR Jr (1998) Migration of femoral interference screw after anterior cruciate ligament reconstruction. Am J Knee Surg 11:32-34
    • (1998) Am J Knee Surg , vol.11 , pp. 32-34
    • Bush-Joseph, C.A.1    Bach Jr., B.R.2
  • 7
    • 0027762738 scopus 로고
    • Arthroscopic placement of the interference screw for anterior cruciate ligament reconstruction
    • Cerullo G, Puddu G (1993) Arthroscopic placement of the interference screw for anterior cruciate ligament reconstruction. Arthroscopy 9:712-713
    • (1993) Arthroscopy , vol.9 , pp. 712-713
    • Cerullo, G.1    Puddu, G.2
  • 8
    • 0025202383 scopus 로고
    • A complication of interference screw fixation in anterior cruciate ligament reconstruction
    • Doerr AL Jr, Cohn BT, Ruoff MJ, McInerny VK (1990) A complication of interference screw fixation in anterior cruciate ligament reconstruction. Orthop Rev 19:997-1000
    • (1990) Orthop Rev , vol.19 , pp. 997-1000
    • Doerr Jr., A.L.1    Cohn, B.T.2    Ruoff, M.J.3    McInerny, V.K.4
  • 9
    • 28444438638 scopus 로고    scopus 로고
    • Intraarticular migration of femoral interference screw: Open or arthroscopic removal
    • Karlakki SL, Downes ME (2003) Intraarticular migration of femoral interference screw: open or arthroscopic removal. Arthroscopy 19:19E
    • (2003) Arthroscopy , vol.19
    • Karlakki, S.L.1    Downes, M.E.2
  • 10
    • 0028244250 scopus 로고
    • Primary stability of interference screw fixation. Influence of screw diameter and insertion torque
    • Kohn D, Rose C (1994) Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am J Sports Med 22:334-338
    • (1994) Am J Sports Med , vol.22 , pp. 334-338
    • Kohn, D.1    Rose, C.2
  • 11
    • 24044546519 scopus 로고    scopus 로고
    • Severe cartilage damage by broken poly-L-lactic acid (PLLA) interference screw after ACL reconstruction
    • Lembeck B, Wülker N (2005) Severe cartilage damage by broken poly-L-lactic acid (PLLA) interference screw after ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 13:283-286
    • (2005) Knee Surg Sports Traumatol Arthrosc , vol.13 , pp. 283-286
    • Lembeck, B.1    Wülker, N.2
  • 12
  • 13
    • 0642307109 scopus 로고    scopus 로고
    • Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction
    • MacDonald P, Arneja S (2003) Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction. Arthroscopy 19: E22-E24
    • (2003) Arthroscopy , vol.19
    • MacDonald, P.1    Arneja, S.2
  • 14
    • 0031302303 scopus 로고    scopus 로고
    • Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report
    • Marti C, Imhoff AB, Bahrs C, Romero J (1997) Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc 5:217-221
    • (1997) Knee Surg Sports Traumatol Arthrosc , vol.5 , pp. 217-221
    • Marti, C.1    Imhoff, A.B.2    Bahrs, C.3    Romero, J.4
  • 15
    • 0032957063 scopus 로고    scopus 로고
    • Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation
    • Martinek V, Friederich NF (1999) Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317-320
    • (1999) Arthroscopy , vol.15 , pp. 317-320
    • Martinek, V.1    Friederich, N.F.2
  • 16
    • 2342420997 scopus 로고    scopus 로고
    • Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo
    • Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS (2002) Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy 18:E47
    • (2002) Arthroscopy , vol.18
    • Morgan, C.D.1    Gehrmann, R.M.2    Jayo, M.J.3    Johnson, C.S.4
  • 18
    • 34047228962 scopus 로고    scopus 로고
    • Broken poly-L-lactic acid interference screw after ligament reconstruction
    • Shafer BL, Simonian PT (2002) Broken poly-L-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35
    • (2002) Arthroscopy , vol.18
    • Shafer, B.L.1    Simonian, P.T.2
  • 19
    • 0031004843 scopus 로고    scopus 로고
    • Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction
    • Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268-271
    • (1997) Am J Sports Med , vol.25 , pp. 268-271
    • Sidhu, D.S.1    Wroble, R.R.2
  • 20
    • 0030903593 scopus 로고    scopus 로고
    • Clinical degradation and biocompatibility of different bioabsorbable interference screws: A report of six cases
    • Stähelin AC, Weiler A, Rüfenacht H, Hoffmann R, Geissmann A, Feinstein R. (1997) Clinical degradation and biocompatibility of different bioabsorbable interference screws: a report of six cases. Arthroscopy 13:238-244
    • (1997) Arthroscopy , vol.13 , pp. 238-244
    • Stähelin, A.C.1    Weiler, A.2    Rüfenacht, H.3    Hoffmann, R.4    Geissmann, A.5    Feinstein, R.6
  • 21
    • 0035161885 scopus 로고    scopus 로고
    • Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons
    • Stähelin AC, Südkamp NP, Weiler A (2001) Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons. Arthroscopy 17:88-97
    • (2001) Arthroscopy , vol.17 , pp. 88-97
    • Stähelin, A.C.1    Südkamp, N.P.2    Weiler, A.3
  • 22
    • 0036357684 scopus 로고    scopus 로고
    • Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction
    • Werner A, Wild A, Ilg A, Krauspe R (2002) Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 10:30-32
    • (2002) Knee Surg Sports Traumatol Arthrosc , vol.10 , pp. 30-32
    • Werner, A.1    Wild, A.2    Ilg, A.3    Krauspe, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.