-
1
-
-
0042331009
-
"Radiochromic film for Medical Radiation Dosimetry"
-
Butson, M.J., Yu, K.N., Cheung, T., Metcalfe, P.E., "Radiochromic film for Medical Radiation Dosimetry", Materials Science & Engineering R: Reports, 41, 61-120, 2003.
-
(2003)
Materials Science & Engineering R: Reports
, vol.41
, pp. 61-120
-
-
Butson, M.J.1
Yu, K.N.2
Cheung, T.3
Metcalfe, P.E.4
-
2
-
-
12444335962
-
"Radiochromic film: The new x-ray dosimetry and imaging tool"
-
Butson, M.J., Cheung, T., Yu, K.N., "Radiochromic film: the new x-ray dosimetry and imaging tool", Australasian Physical & Engineering Sciences in Medicine, 27, 230, 2004.
-
(2004)
Australasian Physical & Engineering Sciences in Medicine
, vol.27
, pp. 230
-
-
Butson, M.J.1
Cheung, T.2
Yu, K.N.3
-
3
-
-
0037148114
-
"Multilayer Gafchromic film detectors for breast skin dose determination in vivo"
-
Cheung, T., Butson, M.J., Yu, K.N., "Multilayer Gafchromic film detectors for breast skin dose determination in vivo", Physics in Medicine and Biology, 47, N31-37, 2002.
-
(2002)
Physics in Medicine and Biology
, vol.47
-
-
Cheung, T.1
Butson, M.J.2
Yu, K.N.3
-
4
-
-
4644334879
-
Dose response characteristics of new models of GAFCHROMIC films: Dependence on densitometer light source and radiation energy
-
Sep
-
Chiu-Tsao ST, Duckworth T, Zhang C, Patel NS, Hsiung CY, Wang L, Shih JA, Harrison LB.Dose response characteristics of new models of GAFCHROMIC films: dependence on densitometer light source and radiation energy. Med Phys. Sep;31(9):2501-8, 2004.
-
(2004)
Med Phys.
, vol.31
, Issue.9
, pp. 2501-2508
-
-
Chiu-Tsao, S.T.1
Duckworth, T.2
Zhang, C.3
Patel, N.S.4
Hsiung, C.Y.5
Wang, L.6
Shih, J.A.7
Harrison, L.B.8
-
5
-
-
0141743737
-
High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields
-
Mack A, Mack G, Weltz D, Scheib SG, Bottcher HD, Seifert V. High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields. Med Phys. 30(9):2399-409, 2003.
-
(2003)
Med Phys.
, vol.30
, Issue.9
, pp. 2399-2409
-
-
Mack, A.1
Mack, G.2
Weltz, D.3
Scheib, S.G.4
Bottcher, H.D.5
Seifert, V.6
-
6
-
-
0034750733
-
"Spatial resolution of a stacked radiochromic film dosimeter"
-
2001
-
Butson, M.J., Cheung, T., Yu, K.N., "Spatial resolution of a stacked radiochromic film dosimeter", 2001, Radiotherapy and Oncology, 61, 211-213, 2001.
-
(2001)
Radiotherapy and Oncology
, vol.61
, pp. 211-213
-
-
Butson, M.J.1
Cheung, T.2
Yu, K.N.3
-
7
-
-
0031466420
-
Gafchromic MD-55: Investigated as a precision dosimeter
-
Klassen N., Zwan L., Cygler J., Gafchromic MD-55: investigated as a precision dosimeter. Med phys 24 1924-1934, 1997.
-
(1997)
Med Phys
, vol.24
, pp. 1924-1934
-
-
Klassen, N.1
Zwan, L.2
Cygler, J.3
-
8
-
-
22544486853
-
"XR type R radiochromic film x-ray energy response"
-
Butson, MJ, Cheung, T., Yu, K.N., "XR type R radiochromic film x-ray energy response", Physics in Medicine and Biology, 50, N195-N199, 2005.
-
(2005)
Physics in Medicine and Biology
, vol.50
-
-
Butson, M.J.1
Cheung, T.2
Yu, K.N.3
-
9
-
-
27644471150
-
"Weak energy dependence of EBT Gafchromic film dose response in the 50 kVp - 10 MVp X-ray range"
-
Cheung, T., Butson, M.J., Yu, K.N., "Weak energy dependence of EBT Gafchromic film dose response in the 50 kVp - 10 MVp X-ray range", Applied Radiation and Isotopes, 64, 60-62, 2006.
-
(2006)
Applied Radiation and Isotopes
, vol.64
, pp. 60-62
-
-
Cheung, T.1
Butson, M.J.2
Yu, K.N.3
-
10
-
-
0031830064
-
Effects of readout light sources and ambient light on radiochromic film
-
Butson M, Yu P, Metcalfe P, Effects of readout light sources and ambient light on radiochromic film Phys Med Biol 43 2407-2412, 1998.
-
(1998)
Phys Med Biol
, vol.43
, pp. 2407-2412
-
-
Butson, M.1
Yu, P.2
Metcalfe, P.3
-
11
-
-
0008796868
-
Radiochromic film dosimetry: Recommendation of AAPM radiation therapy task group 55
-
Niroomand-Rad A, Blackwell C, Coursey B, Gall K, Galvin J, McLaughlin W, Meigooni A, Nath R, Rodgers J, Soares C Radiochromic film dosimetry : Recommendation of AAPM radiation therapy task group 55. Med Phys 25 (11) 2093-2115, 1998.
-
(1998)
Med Phys
, vol.25
, Issue.11
, pp. 2093-2115
-
-
Niroomand-Rad, A.1
Blackwell, C.2
Coursey, B.3
Gall, K.4
Galvin, J.5
McLaughlin, W.6
Meigooni, A.7
Nath, R.8
Rodgers, J.9
Soares, C.10
-
12
-
-
85039247062
-
-
ISP Corp web site
-
ISP Corp web site, www.ispcorp.com, (2005).
-
(2005)
-
-
-
13
-
-
21344465230
-
"Absorption spectra variations of EBT radiochromic film from radiation exposure"
-
Butson, M.J., Cheung, T., Yu, K.N., "Absorption spectra variations of EBT radiochromic film from radiation exposure", Physics in Medicine and Biology, 50, N135-N140, 2005.
-
(2005)
Physics in Medicine and Biology
, vol.50
-
-
Butson, M.J.1
Cheung, T.2
Yu, K.N.3
-
14
-
-
0037153168
-
"High sensitivity radiochromic film dose comparisons"
-
Butson, M.J., Yu, K.N., Cheung, T., Metcalfe, P., "High sensitivity radiochromic film dose comparisons", Physics in Medicine and Biology, 47, N291-N295, 2002.
-
(2002)
Physics in Medicine and Biology
, vol.47
-
-
Butson, M.J.1
Yu, K.N.2
Cheung, T.3
Metcalfe, P.4
-
15
-
-
26244462962
-
"Post irradiation coloration of Gafchromic EBT radiochromic film"
-
Cheung, T., Butson, M.J., Yu, K.N., "Post irradiation coloration of Gafchromic EBT radiochromic film", Physics in Medicine and Biology, 50, N281-N285, 2005.
-
(2005)
Physics in Medicine and Biology
, vol.50
-
-
Cheung, T.1
Butson, M.J.2
Yu, K.N.3
|