메뉴 건너뛰기




Volumn 22, Issue 8, 2006, Pages 811-816

Comparison of partial coherence interferometers: ACMaster versus laboratory prototype

Author keywords

[No Author keywords available]

Indexed keywords

A SCAN; ACCURACY; ANTERIOR EYE SEGMENT; ARTICLE; BIOMETRY; CLINICAL ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; DEVICE; HUMAN; INTERFEROMETER; INTERMETHOD COMPARISON; LABORATORY; LENS; PARTIAL COHERENCE INTERFEROMETER; PRIORITY JOURNAL; PSEUDOPHAKIA; REPRODUCIBILITY;

EID: 33750132893     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20061001-12     Document Type: Article
Times cited : (10)

References (20)
  • 1
    • 0026997738 scopus 로고
    • Prediction of pseudophakic anterior chamber depth with the newer IOL calculation formulas
    • Olsen T, Olesen H, Thim K, Corydon L. Prediction of pseudophakic anterior chamber depth with the newer IOL calculation formulas. J Cataract Refract Surg. 1992;18:280-285.
    • (1992) J Cataract Refract Surg , vol.18 , pp. 280-285
    • Olsen, T.1    Olesen, H.2    Thim, K.3    Corydon, L.4
  • 2
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992;18:125-129.
    • (1992) J Cataract Refract Surg , vol.18 , pp. 125-129
    • Olsen, T.1
  • 3
    • 0030817812 scopus 로고    scopus 로고
    • Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations
    • Holladay JT. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg. 1997;23:1356-1370.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1356-1370
    • Holladay, J.T.1
  • 4
    • 0027276169 scopus 로고
    • Refractive power calculations for intraocular lenses in the phakic eye
    • Holladay JT. Refractive power calculations for intraocular lenses in the phakic eye. Am J Ophthalmol. 1993;116:63-66.
    • (1993) Am J Ophthalmol , vol.116 , pp. 63-66
    • Holladay, J.T.1
  • 5
    • 3442884835 scopus 로고    scopus 로고
    • Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: A randomized trial
    • Findl O, Kriechbaum K, Menapace R, Koeppl C, Sacu S, Wirtitsch M, Buehl W, Drexler W. Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: a randomized trial. Ophthalmology. 2004;111:1515-1521.
    • (2004) Ophthalmology , vol.111 , pp. 1515-1521
    • Findl, O.1    Kriechbaum, K.2    Menapace, R.3    Koeppl, C.4    Sacu, S.5    Wirtitsch, M.6    Buehl, W.7    Drexler, W.8
  • 7
    • 0021717908 scopus 로고
    • Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses: Optical analysis
    • Nakazawa M, Ohtsuki K. Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses: optical analysis. Invest Ophthalmol Vis Sci. 1984;25:1458-1460.
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , pp. 1458-1460
    • Nakazawa, M.1    Ohtsuki, K.2
  • 9
    • 24944490849 scopus 로고    scopus 로고
    • Clinical outcome of wavefront-guided laser in situ keratomileusis in eyes with moderate to high myopia with thin corneas
    • Kremer I, Bahar I, Hirsh A, Levinger S. Clinical outcome of wavefront-guided laser in situ keratomileusis in eyes with moderate to high myopia with thin corneas. J Cataract Refract Surg. 2005;31:1366-1371.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1366-1371
    • Kremer, I.1    Bahar, I.2    Hirsh, A.3    Levinger, S.4
  • 10
    • 0024539797 scopus 로고
    • Immersion versus contact technique in the measurement of axial length by ultrasound
    • Olsen T, Nielsen PJ. Immersion versus contact technique in the measurement of axial length by ultrasound. Acta Ophthalmol (Copenh). 1989;67;101-102.
    • (1989) Acta Ophthalmol (Copenh) , vol.67 , pp. 101-102
    • Olsen, T.1    Nielsen, P.J.2
  • 11
    • 0024309262 scopus 로고
    • The accuracy of ultrasonic determination of axial length in pseudophakic eyes
    • Olsen T. The accuracy of ultrasonic determination of axial length in pseudophakic eyes. Acta Ophthalmol (Copenh). 1989;67:141-144.
    • (1989) Acta Ophthalmol (Copenh) , vol.67 , pp. 141-144
    • Olsen, T.1
  • 12
    • 0036169561 scopus 로고    scopus 로고
    • Anterior chamber depth measurement: A-scan versus optical methods
    • Koranyi G, Lydahl E, Norrby S, Taube M. Anterior chamber depth measurement: a-scan versus optical methods. J Cataract Refract Surg. 2002;28:243-247.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 243-247
    • Koranyi, G.1    Lydahl, E.2    Norrby, S.3    Taube, M.4
  • 19
    • 0036224912 scopus 로고    scopus 로고
    • Application of the Bland-Altman plot for interpretation of method-comparison studies: A critical investigation of its practice
    • Dewitte K, Fierens C, Stockl D, Thienpont LM. Application of the Bland-Altman plot for interpretation of method-comparison studies: a critical investigation of its practice. Clin Chem. 2002;48:799-802.
    • (2002) Clin Chem , vol.48 , pp. 799-802
    • Dewitte, K.1    Fierens, C.2    Stockl, D.3    Thienpont, L.M.4
  • 20
    • 0030863198 scopus 로고    scopus 로고
    • Biometric investigation of changes in the anterior eye segment during accommodation
    • Drexler W, Baumgartner A, Findl O, Hitzenberger CK, Fercher AF. Biometric investigation of changes in the anterior eye segment during accommodation. Vision Res. 1997;37:2789-2800.
    • (1997) Vision Res , vol.37 , pp. 2789-2800
    • Drexler, W.1    Baumgartner, A.2    Findl, O.3    Hitzenberger, C.K.4    Fercher, A.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.