메뉴 건너뛰기




Volumn 50, Issue 6, 2006, Pages 718-721

Oscillometric brachial mean artery pressures are higher than intra-radial mean artery pressures in intensive care unit patients receiving norepinephrine

Author keywords

Adult; Blood pressure determinations; Human; Intensive care unit; Norepinephrine; Vasoconstrictor agents

Indexed keywords

NORADRENALIN; VASOCONSTRICTOR AGENT;

EID: 33750125899     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2006.01045.x     Document Type: Article
Times cited : (30)

References (8)
  • 1
    • 0026753406 scopus 로고
    • Does radial artery pressure accurately reflect aortic pressure?
    • Pauca AL, Wallenhaupt SL, Kon ND, Tucker WY. Does radial artery pressure accurately reflect aortic pressure? Chest 1992; 102: 1193-8.
    • (1992) Chest , vol.102 , pp. 1193-1198
    • Pauca, A.L.1    Wallenhaupt, S.L.2    Kon, N.D.3    Tucker, W.Y.4
  • 2
    • 0031717777 scopus 로고    scopus 로고
    • Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    • DOI 10.1097/00003246-199810000-00014
    • Dorman T, Breslow MJ, Lipsett PA, Rosenberg JM, Balser JR, Almog Y et al. Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med 1998; 26: 1646-9. (Pubitemid 28467671)
    • (1998) Critical Care Medicine , vol.26 , Issue.10 , pp. 1646-1649
    • Dorman, T.1
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0034051418 scopus 로고    scopus 로고
    • Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    • Bur A, Hirschl MM, Herkner H, Oschatz E, Kofler J, Woisetschlager C et al. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Crit Care Med 2000; 28: 371-6. (Pubitemid 30120875)
    • (2000) Critical Care Medicine , vol.28 , Issue.2 , pp. 371-376
    • Bur, A.1    Hirschl, M.M.2    Herkner, H.3    Oschatz, E.4    Kofler, J.5    Woisetschlager, C.6    Laggner, A.N.7
  • 7
    • 0035527552 scopus 로고    scopus 로고
    • Oscillometric blood pressure measurement: Progress and problems
    • DOI 10.1097/00126097-200112000-00004
    • Van Montfrans GA. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit 2001; 6: 287-90. (Pubitemid 34194881)
    • (2001) Blood Pressure Monitoring , vol.6 , Issue.6 , pp. 287-290
    • Van Montfrans, G.A.1
  • 8
    • 0028037508 scopus 로고
    • Thermoregulatory and anesthetic-induced alterations in the differences among femoral, radial, and oscillometric blood pressures
    • DOI 10.1097/00000542-199412000-00016
    • Hynson JM, Sessler DI, Moayeri A, Katz JA. Thermoregulatory and anesthetic-induced alterations in the differences among femoral, radial, and oscillometric blood pressures. Anesthesiology 1994; 81: 1411-21. (Pubitemid 24381433)
    • (1994) Anesthesiology , vol.81 , Issue.6 , pp. 1411-1421
    • Hynson, J.M.1    Sessler, D.I.2    Moayeri, A.3    Katz, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.