메뉴 건너뛰기




Volumn 50, Issue 6, 2006, Pages 731-735

Comparison of radiographic landmarks and the echocardiographic SVC/RA junction in the positioning of long-term central venous catheters

Author keywords

Central venous catheters; Landmark; SVC RA junction; Transesophageal echocardiography

Indexed keywords

ADULT; AGED; ARTICLE; CENTRAL VENOUS CATHETERIZATION; COMPARATIVE STUDY; ECHOGRAPHY; FEMALE; HEART; HEART ATRIUM; HISTOLOGY; HUMAN; MALE; MIDDLE AGED; PREOPERATIVE CARE; SUPERIOR CAVA VEIN; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 33750118707     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2006.01025.x     Document Type: Article
Times cited : (52)

References (20)
  • 1
    • 0031026808 scopus 로고    scopus 로고
    • Delayed complication of port-a-cath: Perforation of the superior vena cava [5]
    • Kulvatunyou N, Rucinski J, Schein M. Delayed complication of Port-A-Cath: perforation of the superior vena cava. J Clin Oncol 1997; 15: 865. (Pubitemid 27074262)
    • (1997) Journal of Clinical Oncology , vol.15 , Issue.2 , pp. 865
    • Kulvatunyou, N.1    Rucinski, J.2    Schein, M.3
  • 2
    • 0032866834 scopus 로고    scopus 로고
    • Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction
    • DOI 10.1016/S0002-9610(99)00124-5, PII S0002961099001245
    • Petersen J, Delaney JH, Brakstad MT, Rowbotham RK, Bagley CM Jr. Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction. Am J Surg 1999; 178: 38-41. (Pubitemid 29375060)
    • (1999) American Journal of Surgery , vol.178 , Issue.1 , pp. 38-41
    • Petersen, J.1    Delaney, J.H.2    Brakstad, M.T.3    Rowbotham, R.K.4    Bagley Jr., C.M.5
  • 3
    • 0029986309 scopus 로고    scopus 로고
    • Hickman catheters: Left-sided insertion, male gender, and obesity are associated with an increased risk of complications
    • Craft PS,May J, Dorigo A, Hoy C, Plant A. Hickman catheters: left-sided insertion, male gender, and obesity are associated with an increased risk of complications. Aust N Z J Med 1996; 26: 33-9. (Pubitemid 26096362)
    • (1996) Australian and New Zealand Journal of Medicine , vol.26 , Issue.1 , pp. 33-39
    • Craft, P.S.1    May, J.2    Dorigo, A.3    Hoy, C.4    Plant, A.5
  • 5
    • 0028107039 scopus 로고
    • Transesophageal echocardiographic assessment of superior vena cava thrombosis in patients with long-term central venous hemodialysis catheters
    • Grote J, Lufft V, Nikutta P, Van der Lieth H, Bahlmann J, Daniel WG. Transesophageal echocardiographic assessment of superior vena cava thrombosis in patients with long-term central venous hemodialysis catheters. Clin Nephrol 1994; 42: 183-8. (Pubitemid 24287753)
    • (1994) Clinical Nephrology , vol.42 , Issue.3 , pp. 183-188
    • Grote, J.1    Lufft, V.2    Nikutta, P.3    Lieth, H.V.D.4    Bahlmann, J.5    Daniel, W.G.6
  • 7
    • 0003198973 scopus 로고
    • Precautions necessary with central venous catheters: FDA Task Force
    • Food and Drug Administration
    • Food and Drug Administration. Precautions necessary with central venous catheters: FDA Task Force. FDA Drug Bull 1989; 19: 15-6.
    • (1989) FDA Drug Bull , vol.19 , pp. 15-16
  • 8
    • 0021972693 scopus 로고
    • Ventricular tachycardia resulting from central venous catheter tip migration due to arm position changes: Report of two cases
    • Kasten GW, Owens E, Kennedy D. Ventricular tachycardia resulting from central venous catheter tip migration due to arm position changes: report of two cases. Anesthesiology 1985; 62: 185-7. (Pubitemid 15173553)
    • (1985) Anesthesiology , vol.62 , Issue.2 , pp. 185-187
    • Kasten, G.W.1    Owens, E.2    Kennedy, D.3
  • 9
    • 0031669011 scopus 로고    scopus 로고
    • MRI of central venous anatomy: Implications for central venous catheter insertion
    • Aslamy Z, Dewald CL, Heffner JE. MRI of central venous anatomy: implications for central venous catheter insertion. Chest 1998; 114: 820-6. (Pubitemid 28433747)
    • (1998) Chest , vol.114 , Issue.3 , pp. 820-826
    • Aslamy, Z.1    Dewald, C.L.2    Heffner, J.E.3
  • 10
    • 1642420982 scopus 로고    scopus 로고
    • Accurate central venous port-A catheter placement: Intravenous electrocardiography and surface landmark techniques compared by using transesophageal echocardiography
    • Chu KS, Hsu JH,Wang SS, Tang CS, Cheng KI,Wang CK et al. Accurate central venous port-A catheter placement: intravenous electrocardiography and surface landmark techniques compared by using transesophageal echocardiography. Anesth Analg 2004; 98: 910-4.
    • (2004) Anesth Analg , vol.98 , pp. 910-914
    • Chu, K.S.1    Hsu, J.H.2    Wang, S.S.3    Tang, C.S.4    Cheng, K.I.5    Wang, C.K.6
  • 11
    • 0033051551 scopus 로고    scopus 로고
    • A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients
    • DOI 10.1097/00000539-199907000-00012
    • Andropoulos DB, Stayer SA, Bent ST, Campos CJ, Bezold LI, Alvarez M et al. A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients. Anesth Analg 1999; 89: 65-70. (Pubitemid 29293310)
    • (1999) Anesthesia and Analgesia , vol.89 , Issue.1 , pp. 65-70
    • Andropoulos, D.B.1    Stayer, S.A.2    Bent, S.T.3    Campos, C.J.4    Bezold, L.I.5    Alvarez, M.6    Fraser, C.D.7
  • 12
    • 0032866834 scopus 로고    scopus 로고
    • Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction
    • DOI 10.1016/S0002-9610(99)00124-5, PII S0002961099001245
    • Petersen J, Delaney JH, Brakstad MT, Rowbotham RK, Bagley CM Jr. Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction. Am J Surg 1999; 178: 38-41. (Pubitemid 29375060)
    • (1999) American Journal of Surgery , vol.178 , Issue.1 , pp. 38-41
    • Petersen, J.1    Delaney, J.H.2    Brakstad, M.T.3    Rowbotham, R.K.4    Bagley Jr., C.M.5
  • 13
    • 0026741305 scopus 로고
    • Vascular erosion by central venous catheters. Clinical features and outcome
    • Duntley P, Siever J, Korwes ML, Harpel K, Heffner JE. Vascular erosion by central venous catheters. Clinical features and outcome. Chest 1992; 101: 1633-8.
    • (1992) Chest , vol.101 , pp. 1633-1638
    • Duntley, P.1    Siever, J.2    Korwes, M.L.3    Harpel, K.4    Heffner, J.E.5
  • 14
    • 0022980574 scopus 로고
    • Complications related to subclavian catheters for hemodialysis. Report and review
    • Vanherweghem JL, Cabolet P, Dhaene M, Goldman M, Stolear JC, Sabot JP et al. Complications related to subclavian catheters for hemodialysis. Am J Nephrol 1986; 6: 339-45. (Pubitemid 17216209)
    • (1986) American Journal of Nephrology , vol.6 , Issue.5 , pp. 339-345
    • Vanherweghem, J.-L.1    Cabolet, P.2    Dhaene, M.3
  • 16
    • 0021749284 scopus 로고
    • Cardiac tamponade from central venous catheters. Report of a case and review of the English literature
    • Collier PE, Ryan JJ, Diamond DL. Cardiac tamponade from central venous catheters. Report of a case and review of the English literature. Angiology 1984; 35: 595-600. (Pubitemid 15208972)
    • (1984) Angiology , vol.35 , Issue.9 , pp. 595-600
    • Collier, P.E.1    Ryan, J.J.2    Diamond, D.L.3
  • 18
    • 0014755867 scopus 로고
    • Mechanism of perforation of the heart with production of hydropericdium by a venous catheter and its prevention
    • Brandt RL, Foley WJ, Fink GH, Regan WJ. Mechanism of perforation of the heart with production of hydropericdium by a venous catheter and its prevention. Am J Surg 1970; 119: 311-6.
    • (1970) Am J Surg , vol.119 , pp. 311-316
    • Brandt, R.L.1    Foley, W.J.2    Fink, G.H.3    Regan, W.J.4
  • 19
    • 0033820066 scopus 로고    scopus 로고
    • Fluoroscopic landmark for SVC-RA junction for central venous catheter placement in children
    • Connolly B, Mawson JB, MacDonald CE, Chait P, Mikailian H. Fluoroscopic landmark for SVC-RA junction for central venous catheter placement in children. Pediatr Radiol 2000; 30: 692-5.
    • (2000) Pediatr Radiol , vol.30 , pp. 692-695
    • Connolly, B.1    Mawson, J.B.2    MacDonald, C.E.3    Chait, P.4    Mikailian, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.