메뉴 건너뛰기




Volumn 17, Issue 10, 2006, Pages 1671-1675

Needle biopsy of anatomically unfavorable liver lesions with an electromagnetic navigation assist device in a computed tomography environment

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; ELECTROMAGNETIC NAVIGATION ASSIST DEVICE; FLUOROSCOPY; LIVER BIOPSY; LIVER DISEASE; NEEDLE; NEEDLE BIOPSY; NONHUMAN; PRIORITY JOURNAL; RADIATION DOSE; SWINE;

EID: 33750077788     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.RVI.0000236589.74137.F6     Document Type: Article
Times cited : (27)

References (10)
  • 1
    • 0142179107 scopus 로고    scopus 로고
    • Procedures, spectrum and radiation exposure in CT-fluoroscopy
    • Stoeckelhuber BM, Schulz E, Melchert UH, et al. Procedures, spectrum and radiation exposure in CT-fluoroscopy. Rontgenpraxis 2003; 55:51-57.
    • (2003) Rontgenpraxis , vol.55 , pp. 51-57
    • Stoeckelhuber, B.M.1    Schulz, E.2    Melchert, U.H.3
  • 2
    • 33646457091 scopus 로고    scopus 로고
    • Increasing registration precision for liver movement with respiration using electromagnetic tracking
    • Zhang H, Banovac F, Cleary K. Increasing registration precision for liver movement with respiration using electromagnetic tracking. Proc Comp Assist Radiol Surg 2005; 571-576.
    • (2005) Proc Comp Assist Radiol Surg , pp. 571-576
    • Zhang, H.1    Banovac, F.2    Cleary, K.3
  • 3
    • 0032797988 scopus 로고    scopus 로고
    • CT-guided agar marking for localization of nonpalpable peripheral pulmonary lesions
    • Tsuchida M, Yamato Y, Aoki T, et al. CT-guided agar marking for localization of nonpalpable peripheral pulmonary lesions. Chest 1999; 116:139-143.
    • (1999) Chest , vol.116 , pp. 139-143
    • Tsuchida, M.1    Yamato, Y.2    Aoki, T.3
  • 4
    • 23944484445 scopus 로고    scopus 로고
    • Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine
    • Banovac F, Tang J, Xu S, et al. Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine. Med Phys 2005; 32:2698-2705.
    • (2005) Med Phys , vol.32 , pp. 2698-2705
    • Banovac, F.1    Tang, J.2    Xu, S.3
  • 5
    • 0031855685 scopus 로고    scopus 로고
    • A comparison of image guidance systems for sinus surgery
    • Metson R, Gliklich RE, Cosenza M. A comparison of image guidance systems for sinus surgery. Laryngoscope 1998; 108:1164-1170.
    • (1998) Laryngoscope , vol.108 , pp. 1164-1170
    • Metson, R.1    Gliklich, R.E.2    Cosenza, M.3
  • 7
    • 20144389511 scopus 로고    scopus 로고
    • Navigation with electromagnetic tracking for interventional radiology procedures: A feasibility study
    • Wood BJ, Zhang H, Durrani A, et al. Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Interv Radiol 2005; 16:493-505.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 493-505
    • Wood, B.J.1    Zhang, H.2    Durrani, A.3
  • 8
    • 0034546682 scopus 로고    scopus 로고
    • Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: A comparison of two image registration methods
    • Solomon SB, White P Jr, Wiener CM, et al. Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: a comparison of two image registration methods. Chest 2000; 118:1783-1787.
    • (2000) Chest , vol.118 , pp. 1783-1787
    • Solomon, S.B.1    White Jr., P.2    Wiener, C.M.3
  • 9
    • 31144440672 scopus 로고    scopus 로고
    • Out-of-plane computed-tomography-guided biopsy using a magnetic-field-based navigation system
    • Wallace MJ, Gupta S, Hicks ME. Out-of-plane computed-tomography-guided biopsy using a magnetic-field-based navigation system. Cardiovasc Intervent Radiol 2006; 29:108-113.
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 108-113
    • Wallace, M.J.1    Gupta, S.2    Hicks, M.E.3
  • 10
    • 0034891288 scopus 로고    scopus 로고
    • Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions
    • Holzknecht N, Helmberger T, Schoepf UJ, et al. Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions. Rofo Fortschr Geb Rontgenstr Nuklearmed 2001; 173:612-618.
    • (2001) Rofo Fortschr Geb Rontgenstr Nuklearmed , vol.173 , pp. 612-618
    • Holzknecht, N.1    Helmberger, T.2    Schoepf, U.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.