메뉴 건너뛰기




Volumn 126, Issue 11, 2006, Pages 1218-1224

Development and evaluation of a novel tracheostoma button and fixation system (Provox LaryButton and LaryClip adhesive) to facilitate hands-free tracheoesophageal speech

Author keywords

Button; Fixation; Hands free speech; Tracheostoma; Voice prosthesis

Indexed keywords

ADULT; AGED; ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CLINICAL ARTICLE; DEVICE; ESOPHAGUS SPEECH; FEMALE; HUMAN; LARYNX DISORDER; MALE; PATIENT SATISFACTION; PRIORITY JOURNAL; TRACHEOTOMY; VOICE;

EID: 33750075175     PISSN: 00016489     EISSN: 16512553     Source Type: Journal    
DOI: 10.1080/00016480600702126     Document Type: Article
Times cited : (19)

References (7)
  • 1
    • 0037277730 scopus 로고    scopus 로고
    • Development and clinical assessment of a heat and moisture exchanger with a multi-magnet automatic tracheostoma valve (Provox FreeHands HME) for vocal and pulmonary rehabilitation after total laryngectomy
    • Hilgers FJM, Ackerstaff AH, Van As CJ, Balm AJM, Van den Brekel MWM, Tan IB. Development and clinical assessment of a heat and moisture exchanger with a multi-magnet automatic tracheostoma valve (Provox FreeHands HME) for vocal and pulmonary rehabilitation after total laryngectomy. Acta Otolaryngol (Stockh) 2003;123:91-9.
    • (2003) Acta Otolaryngol (Stockh) , vol.123 , pp. 91-99
    • Hilgers, F.J.M.1    Ackerstaff, A.H.2    Van As, C.J.3    Balm, A.J.M.4    Van Den Brekel, M.W.M.5    Tan, I.B.6
  • 4
    • 0031906882 scopus 로고    scopus 로고
    • Long term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device, Provox® Stomafilter
    • Ackerstaff AH, Hilgers FJM, Balm AJM, Tan IB. Long term compliance of laryngectomized patients with a specialized pulmonary rehabilitation device, Provox® Stomafilter. Laryngoscope 1998;108:257-60.
    • (1998) Laryngoscope , vol.108 , pp. 257-260
    • Ackerstaff, A.H.1    Hilgers, F.J.M.2    Balm, A.J.M.3    Tan, I.B.4
  • 6
    • 0023773095 scopus 로고
    • An endostomal tracheostomy tube for leakproof retention of the Blom-Singer stomal valve
    • Barton D, DeSanto L, Pearson BW, Keith R. An endostomal tracheostomy tube for leakproof retention of the Blom-Singer stomal valve. Otolaryngol Head Neck Surg 1988;99:38-41.
    • (1988) Otolaryngol Head Neck Surg , vol.99 , pp. 38-41
    • Barton, D.1    Desanto, L.2    Pearson, B.W.3    Keith, R.4
  • 7
    • 0033970128 scopus 로고    scopus 로고
    • Experience with Barton button and peristomal breathing valve attachments for hands-free tracheoesophageal speech
    • Lewin JS, Lemon JC, Bishop-Leone JK, Leyk S, Martin JW, Gillenwater AM. Experience with Barton button and peristomal breathing valve attachments for hands-free tracheoesophageal speech. Head Neck 2000;22:142-8.
    • (2000) Head Neck , vol.22 , pp. 142-148
    • Lewin, J.S.1    Lemon, J.C.2    Bishop-Leone, J.K.3    Leyk, S.4    Martin, J.W.5    Gillenwater, A.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.