Volumn 155, Issue 3-4, 2006, Pages 441-445

Sensitive determination of lead by flame atomic absorption spectrometry improved with branched capillary as hydride generator and without phase separation

Author keywords

Branched capillary; Flame atomic absorption spectrometry; Geochemical sample; Hydride generation; Lead

Indexed keywords


EID: 33750046283     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-006-0489-x     Document Type: Article
Times cited : (10)