메뉴 건너뛰기




Volumn 142, Issue 5, 2006, Pages 856-858

Frequency Doubling Technology Perimetry After Clear and Yellow Intraocular Lens Implantation

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; CATARACT; CATARACT EXTRACTION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; HUMAN; LENS IMPLANTATION; PERIMETRY; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RANK SUM TEST; VISUAL ACUITY;

EID: 33750038281     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajo.2006.05.021     Document Type: Article
Times cited : (10)

References (7)
  • 1
    • 0031058190 scopus 로고    scopus 로고
    • Screening for glaucomatous visual field loss with frequency-doubling perimetry
    • Johnson C.A., and Samuels S.J. Screening for glaucomatous visual field loss with frequency-doubling perimetry. Invest Ophthalmol Vis Sci 38 (1997) 413-425
    • (1997) Invest Ophthalmol Vis Sci , vol.38 , pp. 413-425
    • Johnson, C.A.1    Samuels, S.J.2
  • 2
    • 3442877544 scopus 로고    scopus 로고
    • Impact of cataract on the results of frequency-doubling technology perimetry
    • Tanna A.P., Abraham C., Lai J., et al. Impact of cataract on the results of frequency-doubling technology perimetry. Ophthalmology 111 (2004) 1504-1507
    • (2004) Ophthalmology , vol.111 , pp. 1504-1507
    • Tanna, A.P.1    Abraham, C.2    Lai, J.3
  • 3
    • 3042839275 scopus 로고    scopus 로고
    • Effect of cataract extraction on frequency doubling technology perimetry
    • Kook M.S., Yang S.J., Kim S., et al. Effect of cataract extraction on frequency doubling technology perimetry. Am J Ophthalmol 138 (2004) 85-90
    • (2004) Am J Ophthalmol , vol.138 , pp. 85-90
    • Kook, M.S.1    Yang, S.J.2    Kim, S.3
  • 4
    • 4043066611 scopus 로고    scopus 로고
    • Blue light-absorbing intraocular lens and retinal pigment epithelium protection in vitro
    • Sparrow J.R., Miller A.S., and Zhou J. Blue light-absorbing intraocular lens and retinal pigment epithelium protection in vitro. J Cataract Refract Surg 30 (2004) 873-878
    • (2004) J Cataract Refract Surg , vol.30 , pp. 873-878
    • Sparrow, J.R.1    Miller, A.S.2    Zhou, J.3
  • 5
    • 0038281078 scopus 로고    scopus 로고
    • Is there an association between cataract surgery and age-related macular degeneration? Data from three population-based studies
    • Freeman E.E., Munoz B., West S.K., et al. Is there an association between cataract surgery and age-related macular degeneration? Data from three population-based studies. Am J Ophthalmol 135 (2003) 849-856
    • (2003) Am J Ophthalmol , vol.135 , pp. 849-856
    • Freeman, E.E.1    Munoz, B.2    West, S.K.3
  • 6
    • 4143077090 scopus 로고    scopus 로고
    • Light-transmission-spectrum comparison of foldable intraocular lenses
    • Ernest P.H. Light-transmission-spectrum comparison of foldable intraocular lenses. J Cataract Refract Surg 30 (2004) 1755-1758
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1755-1758
    • Ernest, P.H.1
  • 7
    • 27144446144 scopus 로고    scopus 로고
    • Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation
    • Rodriguez-Galietero A., Montes-Mico R., Munoz G., et al. Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation. J Cataract Refract Surg 31 (2005) 1736-1740
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1736-1740
    • Rodriguez-Galietero, A.1    Montes-Mico, R.2    Munoz, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.