메뉴 건너뛰기




Volumn 22, Issue 10, 2006, Pages 845-850

Second- and third-harmonic generation microscopies for the structural imaging of intact tissues;Microscopies multiharmoniques pour l'imagerie structurale de tissus intacts

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN FIBRIL; LIPID;

EID: 33750037334     PISSN: 07670974     EISSN: None     Source Type: Journal    
DOI: 10.1051/medsci/20062210845     Document Type: Review
Times cited : (19)

References (33)
  • 1
    • 0025342635 scopus 로고
    • Two-photon laser scanning fluorescence microscopy
    • Denk W, Strickler JH, Webb WW. Two-photon laser scanning fluorescence microscopy. Science 1990; 248: 73-6.
    • (1990) Science , vol.248 , pp. 73-76
    • Denk, W.1    Strickler, J.H.2    Webb, W.W.3
  • 2
    • 0242353872 scopus 로고    scopus 로고
    • Nonlinear magic: Multiphoton microscopy in the biasciences
    • Zipfel WR, Williams RM, Webb WW. Nonlinear magic: multiphoton microscopy in the biasciences. Nat Biotechnol 2003; 21: 1369-77.
    • (2003) Nat Biotechnol , vol.21 , pp. 1369-1377
    • Zipfel, W.R.1    Williams, R.M.2    Webb, W.W.3
  • 3
    • 30944450665 scopus 로고    scopus 로고
    • Deep tissue two-photon microscopy
    • Helmchen F, Denk W. Deep tissue two-photon microscopy. Nat Methods 2005; 2: 932-40.
    • (2005) Nat Methods , vol.2 , pp. 932-940
    • Helmchen, F.1    Denk, W.2
  • 4
    • 0000851254 scopus 로고    scopus 로고
    • Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy
    • Moreaux L, Sandre O, Blanchard-Desce M, et al. Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy. Opt Lett 2000; 25: 320-2.
    • (2000) Opt Lett , vol.25 , pp. 320-322
    • Moreaux, L.1    Sandre, O.2    Blanchard-Desce, M.3
  • 5
    • 0035116066 scopus 로고    scopus 로고
    • Coherent scattering in multi-harmonic light microscopy
    • Moreaux L, Sandre O, Charpak S, et al. Coherent scattering in multi-harmonic light microscopy. Biophys J 2001; 80: 1568-74.
    • (2001) Biophys J , vol.80 , pp. 1568-1574
    • Moreaux, L.1    Sandre, O.2    Charpak, S.3
  • 6
    • 33644749237 scopus 로고    scopus 로고
    • Overcoming photodamage in second-harmonic generation microscopy: Real-time optical recording of neuronal action potentials
    • Sacconi L, Dombeck DA, Webb WW. Overcoming photodamage in second-harmonic generation microscopy: real-time optical recording of neuronal action potentials. Proc Nat Acad Sci USA 2006; 103: 3124-9.
    • (2006) Proc Nat Acad Sci USA , vol.103 , pp. 3124-3129
    • Sacconi, L.1    Dombeck, D.A.2    Webb, W.W.3
  • 7
    • 0022801395 scopus 로고
    • Optical second-harmonic microscopy, crossed-beam summation and small-angle scattering in rat-tail tendon
    • Freund I, Deutsch M, Sprecher A. Optical second-harmonic microscopy, crossed-beam summation and small-angle scattering in rat-tail tendon. Biophys J 1986; 50: 693-712.
    • (1986) Biophys J , vol.50 , pp. 693-712
    • Freund, I.1    Deutsch, M.2    Sprecher, A.3
  • 8
    • 0036213717 scopus 로고    scopus 로고
    • Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues
    • Campagnola PJ, Millard AC, Terasaki M, et al. Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues. Biophys J 2002; 82: 493-508.
    • (2002) Biophys J , vol.82 , pp. 493-508
    • Campagnola, P.J.1    Millard, A.C.2    Terasaki, M.3
  • 9
    • 0036099519 scopus 로고    scopus 로고
    • Polarization-modulated second harmonic generation in collagen
    • Stoller P, Reiser KM, Celliers PM, et al. Polarization-modulated second harmonic generation in collagen. Biophys J 2002; 82: 3330-42.
    • (2002) Biophys J , vol.82 , pp. 3330-3342
    • Stoller, P.1    Reiser, K.M.2    Celliers, P.M.3
  • 10
    • 0036828286 scopus 로고    scopus 로고
    • Single cell behavior in metastatic primary mammary tumors correlated with gene expressions patterns revealed by molecular profiling
    • Wang W, Wyckoff JB, Frohlich VC, et al. Single cell behavior in metastatic primary mammary tumors correlated with gene expressions patterns revealed by molecular profiling. Cancer Res 2002; 62: 6278-88.
    • (2002) Cancer Res , vol.62 , pp. 6278-6288
    • Wang, W.1    Wyckoff, J.B.2    Frohlich, V.C.3
  • 11
    • 0037285751 scopus 로고    scopus 로고
    • Three-dimensional imaging of collagen using second harmonic generation
    • Cox G, Kable E, Jones A, et al. Three-dimensional imaging of collagen using second harmonic generation. J Struct Biol 2003; 141: 53-62.
    • (2003) J Struct Biol , vol.141 , pp. 53-62
    • Cox, G.1    Kable, E.2    Jones, A.3
  • 12
    • 21244479321 scopus 로고    scopus 로고
    • Interpreting second-harmonic generation images of collagen i fibrils
    • Williams RM, Zipfel WR, Webb WW. Interpreting second-harmonic generation images of collagen i fibrils. Biophys J 2005; 88: 1377-86.
    • (2005) Biophys J , vol.88 , pp. 1377-1386
    • Williams, R.M.1    Zipfel, W.R.2    Webb, W.W.3
  • 13
    • 14944380678 scopus 로고    scopus 로고
    • Imaging coronary artery microstructure using second-harmonic and two-photon fluorescence microscopy
    • Zoumi A, Lu X, Kassab GS, et al. Imaging coronary artery microstructure using second-harmonic and two-photon fluorescence microscopy. Biophys J 2004; 87: 2778-86.
    • (2004) Biophys J , vol.87 , pp. 2778-2786
    • Zoumi, A.1    Lu, X.2    Kassab, G.S.3
  • 14
    • 16544376833 scopus 로고    scopus 로고
    • Second harmonic imaging of intrinsic signals in muscle fibers in situ
    • Both M, Vogel M, Friedrich O, et al. Second harmonic imaging of intrinsic signals in muscle fibers in situ. J Biomed Opt 2004; 9: 882-92.
    • (2004) J Biomed Opt , vol.9 , pp. 882-892
    • Both, M.1    Vogel, M.2    Friedrich, O.3
  • 15
    • 4544303660 scopus 로고    scopus 로고
    • Second-harmonic microscopy of unstained living cardiac myocytes: Measurements of sarcomere length with 20 nm accuracy
    • Boulesteix T, Beaurepaire E, Sauviat MP, et al. Second-harmonic microscopy of unstained living cardiac myocytes: Measurements of sarcomere length with 20 nm accuracy. Opt Lett 2004; 29: 2031-3.
    • (2004) Opt Lett , vol.29 , pp. 2031-2033
    • Boulesteix, T.1    Beaurepaire, E.2    Sauviat, M.P.3
  • 16
    • 33646172938 scopus 로고    scopus 로고
    • Characterization of the myosin-based source for second-harmonic generation from muscle sarcomeres
    • Plotnikov SV, Millard AC, Campagnola PJ, et al. Characterization of the myosin-based source for second-harmonic generation from muscle sarcomeres. Biophys J 2006; 90: 693-703.
    • (2006) Biophys J , vol.90 , pp. 693-703
    • Plotnikov, S.V.1    Millard, A.C.2    Campagnola, P.J.3
  • 17
    • 0038472234 scopus 로고    scopus 로고
    • Uniform polarity microtubule assemblies imaged in native brain tissues by second-harmonic generation microscopy
    • Dombeck DA, Kasischke KA, Vishwasrao HD, et al. Uniform polarity microtubule assemblies imaged in native brain tissues by second-harmonic generation microscopy. Proc Nat Acad Sci USA 2003; 100: 7081-6.
    • (2003) Proc Nat Acad Sci USA , vol.100 , pp. 7081-7086
    • Dombeck, D.A.1    Kasischke, K.A.2    Vishwasrao, H.D.3
  • 18
    • 22944440694 scopus 로고    scopus 로고
    • Second-harmonic imaging of plant polysaccharides
    • Cox G, Moreno N, Feijo J. Second-harmonic imaging of plant polysaccharides. J Biomed Optics 2005; 10: 02413.
    • (2005) J Biomed Optics , vol.10 , pp. 02413
    • Cox, G.1    Moreno, N.2    Feijo, J.3
  • 19
    • 0038578294 scopus 로고    scopus 로고
    • Dynamic imaging of collagen and its modulation in tumors in vivo using second harmonic generation
    • Brown E, McKee T, diTomaso E, et al. Dynamic imaging of collagen and its modulation in tumors in vivo using second harmonic generation. Nat Med 2003; 9: 796-801.
    • (2003) Nat Med , vol.9 , pp. 796-801
    • Brown, E.1    McKee, T.2    Ditomaso, E.3
  • 20
    • 0037795542 scopus 로고    scopus 로고
    • Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second-harmonic generation
    • Zipfel WR, Williams RM, Christie R, et al. Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second-harmonic generation. Proc Nat Acad Sci USA 2003; 100: 7075-80.
    • (2003) Proc Nat Acad Sci USA , vol.100 , pp. 7075-7080
    • Zipfel, W.R.1    Williams, R.M.2    Christie, R.3
  • 21
    • 0141644208 scopus 로고    scopus 로고
    • High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution
    • König K, Riemann J. High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. J Biomed Opt 2003; 8: 432-9.
    • (2003) J Biomed Opt , vol.8 , pp. 432-439
    • König, K.1    Riemann, J.2
  • 22
    • 30344443410 scopus 로고    scopus 로고
    • Micrometer-scale ex vivo multiphaton imaging of unstained arterial wall structure
    • Boulesteix T, Pena AM, Pages N, et al. Micrometer-scale ex vivo multiphaton imaging of unstained arterial wall structure. Cytometry A 2006; 69: 20-6.
    • (2006) Cytometry A , vol.69 , pp. 20-26
    • Boulesteix, T.1    Pena, A.M.2    Pages, N.3
  • 23
    • 39049195472 scopus 로고    scopus 로고
    • Nouvelle approche des fibroses par microscopie multiphotonique avec génération de second harmonique
    • sous presse
    • Hernest M, Pena AM, Strupler M, et al. Nouvelle approche des fibroses par microscopie multiphotonique avec génération de second harmonique. Med Sci (Paris) 2006; 22 (sous presse).
    • (2006) Med Sci (Paris) , vol.22
    • Hernest, M.1    Pena, A.M.2    Strupler, M.3
  • 24
    • 22944484472 scopus 로고    scopus 로고
    • Chiroptical effects in the second harmonic signal of collagens i and iv
    • Pena AM, Boulesteix T, Dartigalongue T, et al. Chiroptical effects in the second harmonic signal of collagens i and iv. J Am Chem Soc 2005; 127: 10314-22.
    • (2005) J Am Chem Soc , vol.127 , pp. 10314-10322
    • Pena, A.M.1    Boulesteix, T.2    Dartigalongue, T.3
  • 25
    • 0031075571 scopus 로고    scopus 로고
    • Nonlinear scanning laser microscopy by third harmonic generation
    • Barad y, Eisenberg H, Horowitz M, et al. Nonlinear scanning laser microscopy by third harmonic generation. Appl Phys Lett 1997; 70: 922-4.
    • (1997) Appl Phys Lett , vol.70 , pp. 922-924
    • Barad, Y.1    Eisenberg, H.2    Horowitz, M.3
  • 27
    • 1942454762 scopus 로고    scopus 로고
    • Depth-resolved structural imaging by third-harmonic generation microscopy
    • Oron D, Yelin D, Tal E, et al. Depth-resolved structural imaging by third-harmonic generation microscopy. J Struct Biol 2004; 147: 3-11.
    • (2004) J Struct Biol , vol.147 , pp. 3-11
    • Oron, D.1    Yelin, D.2    Tal, E.3
  • 28
    • 1942519262 scopus 로고    scopus 로고
    • Higher harmonic generation microscopy for developmental biology
    • Sun CK, Chu SW, Chen SY, et al. Higher harmonic generation microscopy for developmental biology. J Struct Biol 2004; 147: 19-30.
    • (2004) J Struct Biol , vol.147 , pp. 19-30
    • Sun, C.K.1    Chu, S.W.2    Chen, S.Y.3
  • 29
    • 10944271851 scopus 로고    scopus 로고
    • Velocimetric third-harmonic generation microscopy: Micrometer-scale quantification of morphogenetic movements in unstained embryos
    • Débarre D, Supatto W, Farge E, et al. Velocimetric third-harmonic generation microscopy: micrometer-scale quantification of morphogenetic movements in unstained embryos. Opt Lett 2004; 29: 2881-3.
    • (2004) Opt Lett , vol.29 , pp. 2881-2883
    • Débarre, D.1    Supatto, W.2    Farge, E.3
  • 30
    • 31344446932 scopus 로고    scopus 로고
    • Imaging lipid bodies in cells and tissues using third-harmonic generation microscopy
    • Débarre D, Supatto W, Pena AM, et al. Imaging lipid bodies in cells and tissues using third-harmonic generation microscopy. Nat Methods 2006; 3: 47-53.
    • (2006) Nat Methods , vol.3 , pp. 47-53
    • Débarre, D.1    Supatto, W.2    Pena, A.M.3
  • 31
    • 12844267442 scopus 로고    scopus 로고
    • In vivo modulation of morphogenetic movements in Drosophila embryos with femtosecond laser pulses
    • Supatto W, Débarre D, Moulia B, et al. In vivo modulation of morphogenetic movements in Drosophila embryos with femtosecond laser pulses. Proc Nat Acad Sci USA 2005; 102: 1047-52.
    • (2005) Proc Nat Acad Sci USA , vol.102 , pp. 1047-1052
    • Supatto, W.1    Débarre, D.2    Moulia, B.3
  • 32
    • 0141453297 scopus 로고    scopus 로고
    • Green's function formulation for third harmonic generation microscopy
    • Cheng JX, Xie XS. Green's function formulation for third harmonic generation microscopy. J Opt Soc Am B 2002; 19: 1604-10.
    • (2002) J Opt Soc Am B , vol.19 , pp. 1604-1610
    • Cheng, J.X.1    Xie, X.S.2
  • 33
    • 24344451698 scopus 로고    scopus 로고
    • Structure sensitivity in third-harmonic generation microscopy
    • Débarre D, Supatto W, Beaurepaire E. Structure sensitivity in third-harmonic generation microscopy. Opt Lett 2005; 30: 2134-6.
    • (2005) Opt Lett , vol.30 , pp. 2134-2136
    • Débarre, D.1    Supatto, W.2    Beaurepaire, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.