-
1
-
-
0036056769
-
In vitro effectiveness of mechanical thrombectomy devices for large vessel diameter and low-pressure fluid dynamic applications
-
Müller-Hülsbeck S, Grimm J, Leidt J, et al. In vitro effectiveness of mechanical thrombectomy devices for large vessel diameter and low-pressure fluid dynamic applications. J Vasc Interv Radiol 2002; 13:831-839.
-
(2002)
J Vasc Interv Radiol
, vol.13
, pp. 831-839
-
-
Müller-Hülsbeck, S.1
Grimm, J.2
Leidt, J.3
-
2
-
-
1642347577
-
Thrombectomy for acute internal carotid thrombosis: Five thrombectomy devices compared
-
Chant H, Ashleigh R, McCollum C. Thrombectomy for acute internal carotid thrombosis: five thrombectomy devices compared. Eur J Vasc Endovasc Surg 2004; 27:403-408.
-
(2004)
Eur J Vasc Endovasc Surg
, vol.27
, pp. 403-408
-
-
Chant, H.1
Ashleigh, R.2
McCollum, C.3
-
4
-
-
0344305422
-
Use of rheolytic thrombectomy in treatment of acute massive pulmonary embolism
-
Zeni PT, Blank BG, Peeler DW. Use of rheolytic thrombectomy in treatment of acute massive pulmonary embolism. J Vasc Interv Radiol 2003; 14:1511-1515.
-
(2003)
J Vasc Interv Radiol
, vol.14
, pp. 1511-1515
-
-
Zeni, P.T.1
Blank, B.G.2
Peeler, D.W.3
-
5
-
-
18244393541
-
Pre-procedural administration of aminophylline does not prevent AngioJet rheolytic thrombectomy-induced bradyarrhythmias
-
Lee MS, Makkar RR, Singh V, et al. Pre-procedural administration of aminophylline does not prevent AngioJet rheolytic thrombectomy-induced bradyarrhythmias. J Invas Cardiol 2005; 17:19-22.
-
(2005)
J Invas Cardiol
, vol.17
, pp. 19-22
-
-
Lee, M.S.1
Makkar, R.R.2
Singh, V.3
-
6
-
-
85120189807
-
Re: Use of rheolytic thrombectomy in treatment of acute massive pulmonary embolism
-
Zeni PT, Blank BG, Peeler DW. Re: use of rheolytic thrombectomy in treatment of acute massive pulmonary embolism. J Vasc Interv Radiol 2004; 15:1024.
-
(2004)
J Vasc Interv Radiol
, vol.15
, pp. 1024
-
-
Zeni, P.T.1
Blank, B.G.2
Peeler, D.W.3
-
7
-
-
14644420194
-
Submassive pulmonary embolism and paradoxical embolic stroke treated with percutaneous rheolytic thrombectomy and closure of the patent foramen ovale
-
Iskander A, Nayak A, Chauhan MS. Submassive pulmonary embolism and paradoxical embolic stroke treated with percutaneous rheolytic thrombectomy and closure of the patent foramen ovale. Catheter Cardiovasc Interv 2005; 64:356-360.
-
(2005)
Catheter Cardiovasc Interv
, vol.64
, pp. 356-360
-
-
Iskander, A.1
Nayak, A.2
Chauhan, M.S.3
-
8
-
-
0034770665
-
Type III heart block with peripheral use of the AngioJet thrombectomy system
-
Fontaine AB, Borsa JJ, Hoffer EK, et al. Type III heart block with peripheral use of the AngioJet thrombectomy system. J Vasc Interv Radiol 2001; 12:1223-1225.
-
(2001)
J Vasc Interv Radiol
, vol.12
, pp. 1223-1225
-
-
Fontaine, A.B.1
Borsa, J.J.2
Hoffer, E.K.3
-
9
-
-
0032882444
-
Comparison of the AngioJet rheolytic catheter to surgical thrombectomy for the treatment of thrombosed hemodialysis grafts
-
Vesely TM, Williams D, Weiss M, et al. Comparison of the AngioJet rheolytic catheter to surgical thrombectomy for the treatment of thrombosed hemodialysis grafts. J Vasc Interv Radiol 1999; 10:1195-1205.
-
(1999)
J Vasc Interv Radiol
, vol.10
, pp. 1195-1205
-
-
Vesely, T.M.1
Williams, D.2
Weiss, M.3
-
10
-
-
0030711757
-
Rheolytic thrombectomy with use of the AngioJet-F105 catheter: Preclinical evaluation of safety
-
Sharafuddin MJ, Hicks ME, Marshall E, et al. Rheolytic thrombectomy with use of the AngioJet-F105 catheter: preclinical evaluation of safety. J Vasc Interv Radiol 1997; 8:939-945.
-
(1997)
J Vasc Interv Radiol
, vol.8
, pp. 939-945
-
-
Sharafuddin, M.J.1
Hicks, M.E.2
Marshall, E.3
-
11
-
-
19444366760
-
Mechanoelectrical excitation by fluid jets in monolayers of cultured cardiac myocytes
-
Kong CR, Bursac N, Tung L. Mechanoelectrical excitation by fluid jets in monolayers of cultured cardiac myocytes. J Appl Physiol 2005; 98:2328-2336.
-
(2005)
J Appl Physiol
, vol.98
, pp. 2328-2336
-
-
Kong, C.R.1
Bursac, N.2
Tung, L.3
-
12
-
-
0029922186
-
Effect of gadolinium on stretch-induced changes in contraction and intracellularly recorded action- and afterpotentials of rat isolated atrium
-
Tavi P, Laine M, Weckstrom M. Effect of gadolinium on stretch-induced changes in contraction and intracellularly recorded action- and afterpotentials of rat isolated atrium. Br J Pharmacol 1996; 118:407-413.
-
(1996)
Br J Pharmacol
, vol.118
, pp. 407-413
-
-
Tavi, P.1
Laine, M.2
Weckstrom, M.3
-
13
-
-
0033646472
-
Modification of stretch-induced shortening of repolarization by streptomycin in the isolated rabbit heart
-
Eckardt L, Kirchof P, Mönnig G, et al. Modification of stretch-induced shortening of repolarization by streptomycin in the isolated rabbit heart. J Cardiovasc Pharmacol 2000; 36:711-721.
-
(2000)
J Cardiovasc Pharmacol
, vol.36
, pp. 711-721
-
-
Eckardt, L.1
Kirchof, P.2
Mönnig, G.3
|