메뉴 건너뛰기




Volumn 69, Issue 2, 2006, Pages 254-257

Selective response of dopamine in the presence of ascorbic acid on l-cysteine self-assembled gold electrode

Author keywords

Chronoamperometric method; Dopamine; l Cysteine; Modified electrode

Indexed keywords

CHRONOAMPEROMETRIC METHOD; DOPAMINE; L-CYSTEINE; MODIFIED ELECTRODE;

EID: 33750013233     PISSN: 15675394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2006.03.005     Document Type: Article
Times cited : (50)

References (30)
  • 1
    • 0023767220 scopus 로고
    • Detection of dopamine dynamics in the brain
    • Wightman R.M., May L.J., and Michael A.C. Detection of dopamine dynamics in the brain. Anal. Chem. 60 (1988) 769A-779A
    • (1988) Anal. Chem. , vol.60
    • Wightman, R.M.1    May, L.J.2    Michael, A.C.3
  • 5
    • 0001669030 scopus 로고
    • Marsden C.D., and Fahn S. (Eds), Butterworths, London
    • Jellinger K. In: Marsden C.D., and Fahn S. (Eds). The Pathology of Parkinsonism. Movement Disorders vol. 2 (1987), Butterworths, London 124-165
    • (1987) Movement Disorders , vol.2 , pp. 124-165
    • Jellinger, K.1
  • 6
    • 0029891452 scopus 로고    scopus 로고
    • Dopamine deficits in the brain: the neurochemical basis of Parkinsonian symptoms in AIDS
    • Sardar A.M., Czudek C., and Reynolds G.P. Dopamine deficits in the brain: the neurochemical basis of Parkinsonian symptoms in AIDS. Neuroreport 7 (1996) 910-912
    • (1996) Neuroreport , vol.7 , pp. 910-912
    • Sardar, A.M.1    Czudek, C.2    Reynolds, G.P.3
  • 7
    • 0001522231 scopus 로고
    • Spectrophotometric and titrimetric determination of catecholamines
    • Salem F.B. Spectrophotometric and titrimetric determination of catecholamines. Talanta 34 (1987) 810-812
    • (1987) Talanta , vol.34 , pp. 810-812
    • Salem, F.B.1
  • 8
    • 0026605464 scopus 로고
    • High-performance liquid chromatography with electrochemical detection for the determination of levodopa, catecholamines and their metabolites in rat brain dialysates
    • Sarre S., Michotte Y., Herregodts P., Deleu D., Klippel N.D., and Ebinger G.J. High-performance liquid chromatography with electrochemical detection for the determination of levodopa, catecholamines and their metabolites in rat brain dialysates. Chromatogr 75 (1992) 207-212
    • (1992) Chromatogr , vol.75 , pp. 207-212
    • Sarre, S.1    Michotte, Y.2    Herregodts, P.3    Deleu, D.4    Klippel, N.D.5    Ebinger, G.J.6
  • 9
    • 0034627902 scopus 로고    scopus 로고
    • Simultaneous determination of catecholamines by ion chromatography with direct conductivity detection
    • Guan C.L., Ouyuang J., Li Q.L., et al. Simultaneous determination of catecholamines by ion chromatography with direct conductivity detection. Talanta 50 (2000) 1197-1203
    • (2000) Talanta , vol.50 , pp. 1197-1203
    • Guan, C.L.1    Ouyuang, J.2    Li, Q.L.3
  • 10
    • 84987589151 scopus 로고
    • Nafion-coated fiber electrodes for neurochemical studies in brain tissue
    • Cappella P., Ghasemzadeh B., Mithchell K., and Adams R.N. Nafion-coated fiber electrodes for neurochemical studies in brain tissue. Electroanalysis 2 (1990) 175-182
    • (1990) Electroanalysis , vol.2 , pp. 175-182
    • Cappella, P.1    Ghasemzadeh, B.2    Mithchell, K.3    Adams, R.N.4
  • 11
    • 0021075098 scopus 로고
    • In vivo measurement of dopamine and its metabolites by intracerebral dialysis: changes after d-amphetamine
    • Zetterstrom T., Sharp T., Marsden C.A., and Ungerstedt U. In vivo measurement of dopamine and its metabolites by intracerebral dialysis: changes after d-amphetamine. J. Neurochem. 41 (1983) 1769-1773
    • (1983) J. Neurochem. , vol.41 , pp. 1769-1773
    • Zetterstrom, T.1    Sharp, T.2    Marsden, C.A.3    Ungerstedt, U.4
  • 12
    • 0019597491 scopus 로고
    • Electrochemical treatment of pyrolytic carbon fiber electrodes
    • Gonon F.G., Fomarlet C.M., Buda M.J., and Pujol J.F. Electrochemical treatment of pyrolytic carbon fiber electrodes. Anal. Chem. 53 (1981) 1386-1389
    • (1981) Anal. Chem. , vol.53 , pp. 1386-1389
    • Gonon, F.G.1    Fomarlet, C.M.2    Buda, M.J.3    Pujol, J.F.4
  • 13
    • 0037468560 scopus 로고    scopus 로고
    • Gold nanoparticle arrays for the voltammetric sensing of dopamine
    • Raj C.R., Okyajima T., and Ohsaka T. Gold nanoparticle arrays for the voltammetric sensing of dopamine. Electroanal. Chem. 543 (2003) 127-133
    • (2003) Electroanal. Chem. , vol.543 , pp. 127-133
    • Raj, C.R.1    Okyajima, T.2    Ohsaka, T.3
  • 14
    • 20444473037 scopus 로고    scopus 로고
    • Selective response of dopamine in the presence of ascorbic acid at multi-walled carbon nanotube modified gold electrode
    • Zhang P., Wu F.H., Zhao G.C., and Wei X.W. Selective response of dopamine in the presence of ascorbic acid at multi-walled carbon nanotube modified gold electrode. Bioelectrochemistry 67 (2005) 109-114
    • (2005) Bioelectrochemistry , vol.67 , pp. 109-114
    • Zhang, P.1    Wu, F.H.2    Zhao, G.C.3    Wei, X.W.4
  • 15
    • 0035833596 scopus 로고    scopus 로고
    • Highly selective dopamine quantification using a glassy carbon electrode modified with a melanin-type polymer
    • Rubianes M.D., and Rivas G.A. Highly selective dopamine quantification using a glassy carbon electrode modified with a melanin-type polymer. Anal. Chim. Acta 440 (2001) 99-108
    • (2001) Anal. Chim. Acta , vol.440 , pp. 99-108
    • Rubianes, M.D.1    Rivas, G.A.2
  • 16
    • 0035151705 scopus 로고    scopus 로고
    • Preparation, optimization, and voltammetric characteristics of poly (o-phenylenediamine) film as a dopamine-selective polymeric membrane
    • Ekinci E., Erdoǧdu G., and Karagözler A.E. Preparation, optimization, and voltammetric characteristics of poly (o-phenylenediamine) film as a dopamine-selective polymeric membrane. Appl. Polym. Sci. 79 (2001) 327-332
    • (2001) Appl. Polym. Sci. , vol.79 , pp. 327-332
    • Ekinci, E.1    Erdoǧdu, G.2    Karagözler, A.E.3
  • 17
    • 0032507810 scopus 로고    scopus 로고
    • Simultaneous determination of dopamine and ascorbic acid at poly (neutral red) modified electrodes
    • Sun Y., Ye B., Zhang W., and Zhou X. Simultaneous determination of dopamine and ascorbic acid at poly (neutral red) modified electrodes. Anal. Chim. Acta 363 (1998) 75-80
    • (1998) Anal. Chim. Acta , vol.363 , pp. 75-80
    • Sun, Y.1    Ye, B.2    Zhang, W.3    Zhou, X.4
  • 18
    • 0035866627 scopus 로고    scopus 로고
    • Simultaneous measurement of dopamine and ascorbate at their physiological levels using voltammetric microprobe based on overoxidized poly (1,2-phenylenediamine)-coated carbon fiber
    • Mo J.W., and Ogorevc B. Simultaneous measurement of dopamine and ascorbate at their physiological levels using voltammetric microprobe based on overoxidized poly (1,2-phenylenediamine)-coated carbon fiber. Anal. Chem. 73 (2001) 1196-1202
    • (2001) Anal. Chem. , vol.73 , pp. 1196-1202
    • Mo, J.W.1    Ogorevc, B.2
  • 19
    • 30144439846 scopus 로고    scopus 로고
    • Voltammetric investigation of cytochrome c on gold coated with a self-assembled glutathione monolayer
    • Wu Y., and Hu S. Voltammetric investigation of cytochrome c on gold coated with a self-assembled glutathione monolayer. Bioelectrochemistry 68 (2006) 105-112
    • (2006) Bioelectrochemistry , vol.68 , pp. 105-112
    • Wu, Y.1    Hu, S.2
  • 20
    • 0036314433 scopus 로고    scopus 로고
    • New electroanalytical applications of self-assembled monolayers
    • Mirsky V.M. New electroanalytical applications of self-assembled monolayers. TrAC, Trends Anal. Chem. 21 (2002) 439-450
    • (2002) TrAC, Trends Anal. Chem. , vol.21 , pp. 439-450
    • Mirsky, V.M.1
  • 21
    • 20444476271 scopus 로고    scopus 로고
    • Electrochemical studies of 6-mercapronicotinic acid monolayer on Au electrode
    • Raj C.R., and Behera S. Electrochemical studies of 6-mercapronicotinic acid monolayer on Au electrode. Electroanal. Chem. 581 (2005) 61-69
    • (2005) Electroanal. Chem. , vol.581 , pp. 61-69
    • Raj, C.R.1    Behera, S.2
  • 22
    • 0034767909 scopus 로고    scopus 로고
    • Electrochemical response of dopamine at a penicilamine self-assembled on polycrystalline gold electrode
    • Wang Q., Dong D., and Li N.Q. Electrochemical response of dopamine at a penicilamine self-assembled on polycrystalline gold electrode. Bioelectrochemistry 54 (2001) 169-175
    • (2001) Bioelectrochemistry , vol.54 , pp. 169-175
    • Wang, Q.1    Dong, D.2    Li, N.Q.3
  • 23
    • 0027393509 scopus 로고
    • Self-assembled monolayers in electroanalytical chemistry: application of w-mercapto carboxylic acid monolayers for the electrochemical detection of dopamine in the presence of a high concentration of ascorbic acid
    • Malem F., and Mandler D. Self-assembled monolayers in electroanalytical chemistry: application of w-mercapto carboxylic acid monolayers for the electrochemical detection of dopamine in the presence of a high concentration of ascorbic acid. Anal. Chem. 65 (1993) 37-41
    • (1993) Anal. Chem. , vol.65 , pp. 37-41
    • Malem, F.1    Mandler, D.2
  • 24
    • 0035083134 scopus 로고    scopus 로고
    • Electroanalytical applications of cationic self-assembled monolayers: square wave voltammetric determination of dopamine and ascorbic acid
    • Raj C.R., Tokuda K., and Ohsaka T. Electroanalytical applications of cationic self-assembled monolayers: square wave voltammetric determination of dopamine and ascorbic acid. Bioelectrochemistry 53 (2001) 183-191
    • (2001) Bioelectrochemistry , vol.53 , pp. 183-191
    • Raj, C.R.1    Tokuda, K.2    Ohsaka, T.3
  • 25
    • 0033834457 scopus 로고    scopus 로고
    • Electrocatalytic response of dopamine at a dl-homocysteine self-assembled gold electrode
    • Zhang H.M., Li N.Q., and Zhu Z.W. Electrocatalytic response of dopamine at a dl-homocysteine self-assembled gold electrode. Microchemical 64 (2000) 277-282
    • (2000) Microchemical , vol.64 , pp. 277-282
    • Zhang, H.M.1    Li, N.Q.2    Zhu, Z.W.3
  • 26
    • 0005920845 scopus 로고    scopus 로고
    • Simultaneous detection of ascorbic acid and dopamine at gold electrode modified with a self-assembled monolayer of cystamine
    • Jaj C.R., and Ohsaka T. Simultaneous detection of ascorbic acid and dopamine at gold electrode modified with a self-assembled monolayer of cystamine. Electrochemistry 67 (1999) 1175-1177
    • (1999) Electrochemistry , vol.67 , pp. 1175-1177
    • Jaj, C.R.1    Ohsaka, T.2
  • 28
    • 18544364476 scopus 로고    scopus 로고
    • Poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid
    • Jin G.Y., Zhang Y.Z., and Cheng W.X. Poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid. Sens. Actuators, B 107 (2005) 528-534
    • (2005) Sens. Actuators, B , vol.107 , pp. 528-534
    • Jin, G.Y.1    Zhang, Y.Z.2    Cheng, W.X.3
  • 29
    • 0037024331 scopus 로고    scopus 로고
    • Indirect determination of pepsin activity in human seric protein samples by polyphenol oxidase electrodes
    • Forzani E.S., Bernardi M.E., Sisti A.M., Zarzur J.A., and Solis V.M. Indirect determination of pepsin activity in human seric protein samples by polyphenol oxidase electrodes. Anal. Chim. Acta 460 (2002) 163-175
    • (2002) Anal. Chim. Acta , vol.460 , pp. 163-175
    • Forzani, E.S.1    Bernardi, M.E.2    Sisti, A.M.3    Zarzur, J.A.4    Solis, V.M.5
  • 30
    • 12844288691 scopus 로고    scopus 로고
    • Determination of the hydroxyl radical by its adduct formation with phenol and liquid chromatography/electrochemical detection
    • Kilinc E. Determination of the hydroxyl radical by its adduct formation with phenol and liquid chromatography/electrochemical detection. Talanta 65 (2005) 876-881
    • (2005) Talanta , vol.65 , pp. 876-881
    • Kilinc, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.