메뉴 건너뛰기




Volumn 40, Issue 5, 2006, Pages 367-373

Techniques for preserving vertebral artery perfusion during thoracic aortic stent grafting requiring aortic arch landing

Author keywords

[No Author keywords available]

Indexed keywords

ANEURYSM; AORTA ARCH; AORTA GRAFT; ARTERY BYPASS; ARTERY LIGATION; ARTERY PERFUSION; BASILAR ARTERY; CLINICAL ARTICLE; COIL EMBOLIZATION; COMMON CAROTID ARTERY; DEVICE; DISSECTION; ENDOLEAK; FEMALE; FOLLOW UP; GRAFT PATENCY; HUMAN; MALE; PARESIS; PHRENIC NERVE; POSTOPERATIVE COMPLICATION; REVIEW; STENT; SUBCLAVIAN ARTERY; SURGICAL ANATOMY; SURGICAL TECHNIQUE; THORACIC AORTA; THORACIC AORTA ANEURYSM; TREATMENT OUTCOME; VERTEBRAL ARTERY;

EID: 33750000107     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/1538574406293735     Document Type: Review
Times cited : (32)

References (22)
  • 1
    • 10744223716 scopus 로고    scopus 로고
    • Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: Midterm results
    • Czerny M, Cejna M, Hutschala D, et al: Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: Midterm results. J Endovasc Ther 11: 26-32, 2004.
    • (2004) J Endovasc Ther , vol.11 , pp. 26-32
    • Czerny, M.1    Cejna, M.2    Hutschala, D.3
  • 2
    • 7244226217 scopus 로고    scopus 로고
    • Stent-graft repair versus open surgery for the descending aorta: A case-control study
    • Brandt M, Hussel K, Walluscheck KP, et al: Stent-graft repair versus open surgery for the descending aorta: A case-control study. J Endovasc Ther 11:535-538, 2004.
    • (2004) J Endovasc Ther , vol.11 , pp. 535-538
    • Brandt, M.1    Hussel, K.2    Walluscheck, K.P.3
  • 3
    • 0037001001 scopus 로고    scopus 로고
    • Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience
    • Criado FJ, Clark NS, Barnatan MF: Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience. J Vasc Surg 36:1121-1128, 2002.
    • (2002) J Vasc Surg , vol.36 , pp. 1121-1128
    • Criado, F.J.1    Clark, N.S.2    Barnatan, M.F.3
  • 4
    • 0036593014 scopus 로고    scopus 로고
    • Evolving experience with thoracic aortic stent graft repair
    • Cambria RP, Brewster DC, Lauterbach SR, et al: Evolving experience with thoracic aortic stent graft repair. J Vasc Surg 35:1129-11236, 2002.
    • (2002) J Vasc Surg , vol.35 , pp. 1129-11236
    • Cambria, R.P.1    Brewster, D.C.2    Lauterbach, S.R.3
  • 5
    • 4043172849 scopus 로고    scopus 로고
    • Endovascular repair of traumatic descending thoracic aortic disruptions: Should endovascular therapy become the gold standard?
    • Uzieblo M, Sanchez LA, Rubin BG, et al: Endovascular repair of traumatic descending thoracic aortic disruptions: Should endovascular therapy become the gold standard? Vasc Endovasc Surg 38:331-337, 2004.
    • (2004) Vasc Endovasc Surg , vol.38 , pp. 331-337
    • Uzieblo, M.1    Sanchez, L.A.2    Rubin, B.G.3
  • 6
    • 0037636596 scopus 로고    scopus 로고
    • Endovascular repair for acute traumatic rupture of the thoracic aorta
    • Marty-Ane CH, Berthet JP, Branchereau P, et al: Endovascular repair for acute traumatic rupture of the thoracic aorta. Ann Thorac Surg 75:1803-1807, 2003.
    • (2003) Ann Thorac Surg , vol.75 , pp. 1803-1807
    • Marty-Ane, C.H.1    Berthet, J.P.2    Branchereau, P.3
  • 7
    • 4744341846 scopus 로고    scopus 로고
    • Endovascular treatment of thoracic aortic diseases: Combined experience from the EUROSTAR and United Kingdom Thoracic Endograft registries
    • discussion 679-680
    • Leurs LJ, Bell R, Degrieck Y, et al: Endovascular treatment of thoracic aortic diseases: Combined experience from the EUROSTAR and United Kingdom Thoracic Endograft registries. J Vasc Surg 40:670-679; discussion 679-680, 2004.
    • (2004) J Vasc Surg , vol.40 , pp. 670-679
    • Leurs, L.J.1    Bell, R.2    Degrieck, Y.3
  • 8
    • 0035409404 scopus 로고    scopus 로고
    • Ancillary techniques to facilitate endovascular repair of aortic aneurysms
    • Yano OJ, Faries PL, Morrissey N, et al: Ancillary techniques to facilitate endovascular repair of aortic aneurysms. J Vasc Surg 34:69-75, 2001.
    • (2001) J Vasc Surg , vol.34 , pp. 69-75
    • Yano, O.J.1    Faries, P.L.2    Morrissey, N.3
  • 9
    • 0242300258 scopus 로고    scopus 로고
    • Complications after endovascular treatment of thoracic aortic aneurysms
    • Scharrer-Pamler R, Kotsis T, Kapfer X, et al: Complications after endovascular treatment of thoracic aortic aneurysms. J Endovasc Ther 10:711-718, 2003.
    • (2003) J Endovasc Ther , vol.10 , pp. 711-718
    • Scharrer-Pamler, R.1    Kotsis, T.2    Kapfer, X.3
  • 10
    • 0141534252 scopus 로고    scopus 로고
    • Left subclavian artery management in endovascular repair of thoracic aortic aneurysms and aortic dissections
    • Tiesenhausen K, Hausegger KA, Oberwalder P, et al: Left subclavian artery management in endovascular repair of thoracic aortic aneurysms and aortic dissections. J Card Surg 18:429-435, 2003.
    • (2003) J Card Surg , vol.18 , pp. 429-435
    • Tiesenhausen, K.1    Hausegger, K.A.2    Oberwalder, P.3
  • 11
    • 0036616575 scopus 로고    scopus 로고
    • Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs
    • Gorich J, Asquan Y, Seifarth H, et al: Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9(suppl 2):II39-II43, 2002.
    • (2002) J Endovasc Ther , vol.9 , Issue.SUPPL. 2
    • Gorich, J.1    Asquan, Y.2    Seifarth, H.3
  • 12
    • 0022476256 scopus 로고
    • Duplex scanning of normal vertebral arteries
    • Touboul PJ, Bousser MG, LaPlane D, et al: Duplex scanning of normal vertebral arteries. Stroke 17:921-923, 1986.
    • (1986) Stroke , vol.17 , pp. 921-923
    • Touboul, P.J.1    Bousser, M.G.2    Laplane, D.3
  • 13
    • 0036924624 scopus 로고    scopus 로고
    • The circle of Willis in healthy older persons
    • (Torino)
    • Macchi C, Lova RM, Miniati B, et al: The circle of Willis in healthy older persons. J Cardiovasc Surg (Torino) 43:887-890, 2002.
    • (2002) J Cardiovasc Surg , vol.43 , pp. 887-890
    • Macchi, C.1    Lova, R.M.2    Miniati, B.3
  • 14
    • 0141954243 scopus 로고    scopus 로고
    • Endovascular therapy in prevention and management of coronary-subclavian steal
    • discussion 704
    • Westerband A, Rodriguez JA, Ramaiah VG, et al: Endovascular therapy in prevention and management of coronary-subclavian steal. J Vasc Surg 38:699-703; discussion 704, 2003.
    • (2003) J Vasc Surg , vol.38 , pp. 699-703
    • Westerband, A.1    Rodriguez, J.A.2    Ramaiah, V.G.3
  • 15
    • 1842682038 scopus 로고    scopus 로고
    • In situ stent-graft fenestration to preserve the left subclavian artery
    • McWilliams RG, Murphy M, Hartley D, et al: In situ stent-graft fenestration to preserve the left subclavian artery. J Endovasc Ther 11:170-174, 2004.
    • (2004) J Endovasc Ther , vol.11 , pp. 170-174
    • McWilliams, R.G.1    Murphy, M.2    Hartley, D.3
  • 16
    • 0043056861 scopus 로고    scopus 로고
    • Endovascular aortic arch reconstruction with supra-aortic transposition for symptomatic contained rupture and dissection: Early experience in 8 high-risk patients
    • Schumacher H, Bockler D, Bardenheuer H, et al: Endovascular aortic arch reconstruction with supra-aortic transposition for symptomatic contained rupture and dissection: Early experience in 8 high-risk patients. J Endovasc Ther 10:1066-1074, 2003.
    • (2003) J Endovasc Ther , vol.10 , pp. 1066-1074
    • Schumacher, H.1    Bockler, D.2    Bardenheuer, H.3
  • 17
    • 0030475170 scopus 로고    scopus 로고
    • Subclavian carotid transposition: An analysis of a clinical series and a review of the literature
    • Schardey HM, Meyer G, Rau HG, et al: Subclavian carotid transposition: An analysis of a clinical series and a review of the literature. Eur J Vasc Endovasc Surg 12:431-436, 1996.
    • (1996) Eur J Vasc Endovasc Surg , vol.12 , pp. 431-436
    • Schardey, H.M.1    Meyer, G.2    Rau, H.G.3
  • 18
    • 0028021977 scopus 로고
    • Carotid-subclavian bypass: A twenty-two-year experience
    • discussion 417-418
    • Vitti MJ, Thompson BW, Read RC, et al: Carotid-subclavian bypass: A twenty-two-year experience. J Vasc Surg 20:411-417; discussion 417-418, 1994.
    • (1994) J Vasc Surg , vol.20 , pp. 411-417
    • Vitti, M.J.1    Thompson, B.W.2    Read, R.C.3
  • 19
    • 0026742866 scopus 로고
    • The influence of competitive flow on graft patency
    • (Torino)
    • Juleff RS, Brown OW, McKain MM, et al: The influence of competitive flow on graft patency. J Cardiovasc Surg (Torino) 33:415-419, 1992.
    • (1992) J Cardiovasc Surg , vol.33 , pp. 415-419
    • Juleff, R.S.1    Brown, O.W.2    McKain, M.M.3
  • 20
    • 0242721243 scopus 로고    scopus 로고
    • Does competitive flow reduce internal thoracic artery graft patency?
    • discussion 1497
    • Sabik JF III, Lytle BW, Blackstone EH, et al: Does competitive flow reduce internal thoracic artery graft patency? Ann Thorac Surg 76:1490-1496; discussion 1497, 2003.
    • (2003) Ann Thorac Surg , vol.76 , pp. 1490-1496
    • Sabik III, J.F.1    Lytle, B.W.2    Blackstone, E.H.3
  • 21
    • 0346103800 scopus 로고    scopus 로고
    • Development of a branched stent-graft for endovascular repair of aortic arch aneurysms
    • Chuter TA, Buck DG, Schneider DB, et al: Development of a branched stent-graft for endovascular repair of aortic arch aneurysms. J Endovasc Ther 10:940-945, 2003.
    • (2003) J Endovasc Ther , vol.10 , pp. 940-945
    • Chuter, T.A.1    Buck, D.G.2    Schneider, D.B.3
  • 22
    • 0141919793 scopus 로고    scopus 로고
    • Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection
    • Chuter TA, Schneider DB, Reilly LM, et al: Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection. J Vasc Surg 38:859-863, 2003.
    • (2003) J Vasc Surg , vol.38 , pp. 859-863
    • Chuter, T.A.1    Schneider, D.B.2    Reilly, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.