-
1
-
-
0034780316
-
Pathophysiology of dialysis hypotension: An update
-
Daugirdas JT. Pathophysiology of dialysis hypotension: An update. Am J Kidney Dis 2001; 38 [Suppl 4]: 11-17
-
(2001)
Am J Kidney Dis
, vol.38
, Issue.SUPPL. 4
, pp. 11-17
-
-
Daugirdas, J.T.1
-
2
-
-
0034184873
-
Strategies for improving hemodynamic stability in cardiac compromised dialysis patients
-
van der Sande FM, Kooman JP, Leunissen KML. Strategies for improving hemodynamic stability in cardiac compromised dialysis patients. Am J Kidney Dis 2000; 35: E19
-
(2000)
Am J Kidney Dis
, vol.35
-
-
van der Sande, F.M.1
Kooman, J.P.2
Leunissen, K.M.L.3
-
3
-
-
0027515747
-
Dialysis-induced hypotension: A fresh look at pathophysiology
-
Zucchelli P, Santoro A. Dialysis-induced hypotension: A fresh look at pathophysiology. Blood Purif 1993; 11: 85-98
-
(1993)
Blood Purif
, vol.11
, pp. 85-98
-
-
Zucchelli, P.1
Santoro, A.2
-
4
-
-
0027964816
-
Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume
-
Bogaard HJ, de Vries JP, de Vries PM. Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume. Nephrol Dial Transplant 1994; 9: 1283-1287
-
(1994)
Nephrol Dial Transplant
, vol.9
, pp. 1283-1287
-
-
Bogaard, H.J.1
de Vries, J.P.2
de Vries, P.M.3
-
5
-
-
0030739233
-
Blood volume changes during three different profiles of dialysate sodium variation with similar intradialytic sodium balance in chronic hemodialyzed patients
-
Movilli E, Camerini C, Fabio B et al. Blood volume changes during three different profiles of dialysate sodium variation with similar intradialytic sodium balance in chronic hemodialyzed patients. Am J Kidney Dis 1997; 30: 58-63
-
(1997)
Am J Kidney Dis
, vol.30
, pp. 58-63
-
-
Movilli, E.1
Camerini, C.2
Fabio, B.3
-
6
-
-
0031753651
-
Clinical use of profiled hemodialysis
-
Coli L, Bonomini M, Manna GL et al. Clinical use of profiled hemodialysis. Artif Organs 1998; 22: 724-730
-
(1998)
Artif Organs
, vol.22
, pp. 724-730
-
-
Coli, L.1
Bonomini, M.2
Manna, G.L.3
-
7
-
-
0026183904
-
Less symptomatic hypotension using blood volume controlled ultrafiltration
-
Stiller S, Wirtz D, Waterbar F et al. Less symptomatic hypotension using blood volume controlled ultrafiltration. ASAIO Trans 1991; 37: M139-M141
-
(1991)
ASAIO Trans
, vol.37
-
-
Stiller, S.1
Wirtz, D.2
Waterbar, F.3
-
8
-
-
0031038964
-
Impact of profile hemodialysis on intra-/extracellular fluid shifts and the release of vasoactive hormones in elderly patients on regular dialysis treatment
-
Ebel H, Laage C, Keuchel M et al. Impact of profile hemodialysis on intra-/extracellular fluid shifts and the release of vasoactive hormones in elderly patients on regular dialysis treatment. Nephron 1997; 75: 264-271
-
(1997)
Nephron
, vol.75
, pp. 264-271
-
-
Ebel, H.1
Laage, C.2
Keuchel, M.3
-
9
-
-
0035199362
-
Sodium and fluid modulation in dialysis: New approach
-
Splendiani G, Costanzi S, Passalacqua S et al. Sodium and fluid modulation in dialysis: New approach. Nephron 2001; 89: 377-380
-
(2001)
Nephron
, vol.89
, pp. 377-380
-
-
Splendiani, G.1
Costanzi, S.2
Passalacqua, S.3
-
11
-
-
0035465361
-
A critical review of sodium profiling for hemodialysis
-
Stiller S, Bonnie-Schorn E, Grassmann A, Uhlenbusch-Korwer I, Mann H. A critical review of sodium profiling for hemodialysis. Semin Dial 2001; 14: 337-347
-
(2001)
Semin Dial
, vol.14
, pp. 337-347
-
-
Stiller, S.1
Bonnie-Schorn, E.2
Grassmann, A.3
Uhlenbusch-Korwer, I.4
Mann, H.5
-
12
-
-
0029937976
-
The benefits and side effects of ramped hypertonic sodium dialysis
-
Levin A, Goldstein MB. The benefits and side effects of ramped hypertonic sodium dialysis. J Am Soc Nephrol 1996; 7: 242-246
-
(1996)
J Am Soc Nephrol
, vol.7
, pp. 242-246
-
-
Levin, A.1
Goldstein, M.B.2
-
14
-
-
0027688177
-
Sodium modeling ameliorates intradialytic symptoms in young dialysis patients
-
Sadowsky RH, Allred EN, Jabs K. Sodium modeling ameliorates intradialytic symptoms in young dialysis patients. J Am Soc Nephrol 1993; 4: 1192-1198
-
(1993)
J Am Soc Nephrol
, vol.4
, pp. 1192-1198
-
-
Sadowsky, R.H.1
Allred, E.N.2
Jabs, K.3
-
15
-
-
0033919441
-
Ultrafiltration profiling and measurement of relative blood volume as strategies to reduce hemodialysis-related side effects
-
Donauer J, Kolblin D, Bek M, Krause A, Bohler J. Ultrafiltration profiling and measurement of relative blood volume as strategies to reduce hemodialysis-related side effects. Am J Kidney Dis 2000; 36: 115-123
-
(2000)
Am J Kidney Dis
, vol.36
, pp. 115-123
-
-
Donauer, J.1
Kolblin, D.2
Bek, M.3
Krause, A.4
Bohler, J.5
-
16
-
-
0036060909
-
The effect of profiled hemodialysis on intradialytic hemodynamics when a proper sodium balance is applied
-
Straver B, de Vries PMJM, Donker AJM et al. The effect of profiled hemodialysis on intradialytic hemodynamics when a proper sodium balance is applied. Blood Purif 2002; 20: 364-369
-
(2002)
Blood Purif
, vol.20
, pp. 364-369
-
-
Straver, B.1
de Vries, P.M.J.M.2
Donker, A.J.M.3
-
17
-
-
21644484813
-
Effect of sodium balance and the combination of ultrafiltration profile during sodium profiling hemodialysis on the maintenance of the quality of dialysis and sodium and fluid balances
-
Song JH, Park GH, Lee SY, Lee SW, Lee SW, Kim MJ. Effect of sodium balance and the combination of ultrafiltration profile during sodium profiling hemodialysis on the maintenance of the quality of dialysis and sodium and fluid balances. J Am Soc Nephrol 2005; 16: 237-246
-
(2005)
J Am Soc Nephrol
, vol.16
, pp. 237-246
-
-
Song, J.H.1
Park, G.H.2
Lee, S.Y.3
Lee, S.W.4
Lee, S.W.5
Kim, M.J.6
-
19
-
-
0028802591
-
Autonomic nervous function and blood volume monitoring during hemodialysis
-
Henzman G, Panzetta G, Bianco F et al. Autonomic nervous function and blood volume monitoring during hemodialysis. Int J Artif Organs 1995; 18: 504-508
-
(1995)
Int J Artif Organs
, vol.18
, pp. 504-508
-
-
Henzman, G.1
Panzetta, G.2
Bianco, F.3
-
22
-
-
0035841830
-
Sodium balance-neutral sodium profiling does not improve dialysis tolerance
-
Iselin H, Tsinalis D, Brunner FP. Sodium balance-neutral sodium profiling does not improve dialysis tolerance. Swiss Med Wkly 2001; 131: 635-639
-
(2001)
Swiss Med Wkly
, vol.131
, pp. 635-639
-
-
Iselin, H.1
Tsinalis, D.2
Brunner, F.P.3
-
23
-
-
18744368078
-
Blood volume controlled hemodialysis in hypotension-prone patients: A randomized, multicenter controlled trial
-
Santoro A, Mancini E, Basile C et al. Blood volume controlled hemodialysis in hypotension-prone patients: A randomized, multicenter controlled trial. Kidney Int 2002; 62: 1034-1045
-
(2002)
Kidney Int
, vol.62
, pp. 1034-1045
-
-
Santoro, A.1
Mancini, E.2
Basile, C.3
-
24
-
-
0036559047
-
Biofeedback regulation of ultrafiltration and dialysate conductivity for the prevention of hypotension during hemodialysis
-
Begin V, Deziel C, Madore F. Biofeedback regulation of ultrafiltration and dialysate conductivity for the prevention of hypotension during hemodialysis. ASAIO J 2002; 48: 312-315
-
(2002)
ASAIO J
, vol.48
, pp. 312-315
-
-
Begin, V.1
Deziel, C.2
Madore, F.3
|