메뉴 건너뛰기




Volumn 6163, Issue , 2006, Pages

Comparative analysis of sensitivity of different light scattering techniques to Mood oxygenation on the basis of multilayer tissue model

Author keywords

Blood oxygenation level; Light propagation in tissue; Monte Carlo simulation; Optical coherence tomography; Pulse oxymetry; Skin optics; Spatially resolved diffuse reflectometry; Time of flight

Indexed keywords

BLOOD OXYGENATION LEVEL; OPTICAL COHERENCE TOMOGRAPHY; PULSE OXYMETRY; SKIN OPTICS; SPATIALLY RESOLVED DIFFUSE REFLECTOMETRY; TIME OF FLIGHT;

EID: 33749869578     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.697338     Document Type: Conference Paper
Times cited : (10)

References (16)
  • 1
    • 0024562215 scopus 로고
    • Pulse oximetry
    • J. F. Kelleher, "Pulse oximetry," J. Clin. Monit., 5(1), pp. 37-62, (1989).
    • (1989) J. Clin. Monit. , vol.5 , Issue.1 , pp. 37-62
    • Kelleher, J.F.1
  • 2
    • 0032756424 scopus 로고    scopus 로고
    • Influence of the scattering phase function approximation on the optical properties of blood determined from the integrating sphere measurements
    • A.N. Yaroslavsky, I.V. Yaroslavsky, T. Goldbach, and H.J. Schwarzmaier, "Influence of the scattering phase function approximation on the optical properties of blood determined from the integrating sphere measurements", J. Biomed. Opt., 4, pp. 47-53 (1999).
    • (1999) J. Biomed. Opt. , vol.4 , pp. 47-53
    • Yaroslavsky, A.N.1    Yaroslavsky, I.V.2    Goldbach, T.3    Schwarzmaier, H.J.4
  • 3
    • 0004120158 scopus 로고    scopus 로고
    • edit, by B.E. Bouma, G.J. Tearney Marcel Dekker, New York
    • Handbook of Optical Coherence Tomography, edit, by B.E. Bouma, G.J. Tearney (2002, Marcel Dekker, New York).
    • (2002) Handbook of Optical Coherence Tomography
  • 4
    • 0030150929 scopus 로고    scopus 로고
    • Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue
    • A. Kienle, L. Lilge, M.S. Patterson, R. Hibst, R. Steiner and B.C. Wilson, "Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue", Appl. Opt., 35(13), pp. 2306-2314 (1996).
    • (1996) Appl. Opt. , vol.35 , Issue.13 , pp. 2306-2314
    • Kienle, A.1    Lilge, L.2    Patterson, M.S.3    Hibst, R.4    Steiner, R.5    Wilson, B.C.6
  • 5
    • 0013191220 scopus 로고    scopus 로고
    • Influence of the phase function on determination of the optical properties of biological tissue by spatially resolved reflectance
    • A. Kienle, F.K. Forster, and R. Hibst "Influence of the phase function on determination of the optical properties of biological tissue by spatially resolved reflectance", Optics Letters, 26(20), pp. 1571-1573 (2001).
    • (2001) Optics Letters , vol.26 , Issue.20 , pp. 1571-1573
    • Kienle, A.1    Forster, F.K.2    Hibst, R.3
  • 6
    • 0029746220 scopus 로고    scopus 로고
    • Determination of the optical properties of turbid media from a single Monte Carlo simulation
    • A. Kienle and M.S Patterson, "Determination of the optical properties of turbid media from a single Monte Carlo simulation", Phys. Med. Biol., 41, pp. 2221-2227 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2221-2227
    • Kienle, A.1    Patterson, M.S.2
  • 8
    • 13244252339 scopus 로고    scopus 로고
    • Multilayer modeling of reflectance pulse oximetry
    • J.L.Reuss, "Multilayer Modeling of Reflectance Pulse Oximetry", IEEE Trans. Biomed. Eng., 52(2), pp. 153-159 (2005).
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.2 , pp. 153-159
    • Reuss, J.L.1
  • 9
    • 0036825447 scopus 로고    scopus 로고
    • Monte Carlo simulation of laser beam propagation in plain layer of red blood cell suspension. Comparison of contribution of different scattering orders to the angle distribution of light intensity
    • M.Yu. Kirillin and A.V. Priezzhev, "Monte Carlo simulation of laser beam propagation in plain layer of red blood cell suspension. Comparison of contribution of different scattering orders to the angle distribution of light intensity", Quantum Electronics 32, 883-887 (2002).
    • (2002) Quantum Electronics , vol.32 , pp. 883-887
    • Kirillin, M.Y.1    Priezzhev, A.V.2
  • 10
    • 23044444927 scopus 로고    scopus 로고
    • Effect of red blood cell aggregation and sedimentation on optical coherence tomography signals from blood samples
    • M Yu Kirillin, A V Priezzhev, V V Tuchin, R K Wang and R Myllyla "Effect of red blood cell aggregation and sedimentation on optical coherence tomography signals from blood samples", J. Phys. D: Appl. Phys. 38, pp. 2582-2589 (2005).
    • (2005) J. Phys. D: Appl. Phys. , vol.38 , pp. 2582-2589
    • Kirillin, M.Yu.1    Priezzhev, A.V.2    Tuchin, V.V.3    Wang, R.K.4    Myllyla, R.5
  • 12
    • 0035150624 scopus 로고    scopus 로고
    • Modelling the sampling volume for skin blood oxygenation measurements
    • I.V.Meglinski, S.J.Matcher, "Modelling the sampling volume for skin blood oxygenation measurements", Med. Biol. Eng. Comp., 39, pp. 34-50, (2001).
    • (2001) Med. Biol. Eng. Comp. , vol.39 , pp. 34-50
    • Meglinski, I.V.1    Matcher, S.J.2
  • 13
    • 0037036524 scopus 로고    scopus 로고
    • Signal degradation by multiple scattering in optical coherence tomography of dense tissue: A Monte Carlo study towards optical clearing of biotissues
    • R.K. Wang, "Signal degradation by multiple scattering in optical coherence tomography of dense tissue: a Monte Carlo study towards optical clearing of biotissues", Phys. Med. Biol., 47, pp. 2281-2299 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2281-2299
    • Wang, R.K.1
  • 14
    • 0027934282 scopus 로고
    • Optical coherence tomography of a dense tissue: Statistics of attenuation and backscattering
    • J.M. Schmitt, A Knüttel, M Yadlowsky, and M. A. Eckhaus, "Optical coherence tomography of a dense tissue: statistics of attenuation and backscattering", Phys. Med. Biol., 39, pp. 1705-1720 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1705-1720
    • Schmitt, J.M.1    Knüttel, A.2    Yadlowsky, M.3    Eckhaus, M.A.4
  • 15
    • 0036017339 scopus 로고    scopus 로고
    • Dynamic optical coherence tomography in studies of optical clearing, sedimentation, and aggregation of immersed blood
    • V.V. Tuchin, X. Xu, and R.K. Wang, "Dynamic optical coherence tomography in studies of optical clearing, sedimentation, and aggregation of immersed blood", Appl. Optics, 41, pp. 258-271 (2002).
    • (2002) Appl. Optics , vol.41 , pp. 258-271
    • Tuchin, V.V.1    Xu, X.2    Wang, R.K.3
  • 16
    • 0029846409 scopus 로고    scopus 로고
    • The relationship between oxygen saturation and pH in umbilical blood: Implications for intrapartum fetal oxygen saturation monitoring
    • G. A. Dildy, J. A. Thorp, J. D. Yeast, and S. L. Clark, "The relationship between oxygen saturation and pH in umbilical blood: Implications for intrapartum fetal oxygen saturation monitoring," Am. J. Obstet. Gynecol., pt. 1, 175(3), pp. 682-687 (1996).
    • (1996) Am. J. Obstet. Gynecol., Pt. 1 , vol.175 , Issue.3 , pp. 682-687
    • Dildy, G.A.1    Thorp, J.A.2    Yeast, J.D.3    Clark, S.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.